20.4.1 StatusEnumeration
This data type is an enumeration of the possible operation modes of the ice machine. The enumeration values are defined in Table 71.
| Value | Description |
| INIT_0 | Commissioning, started manually (switch on) or automatically (after cleaning) |
| WATER_PURGE_1 | Existing water in the tray is flushed out and fresh water is filled for the next cycle |
| PRE_CHILL_2 | Precooling of the evaporator for xx seconds during the initial commissioning |
| FREEZE_3 | The water freezes on the evaporator to form ice |
| HARVEST_4 | Ice is harvested |
| BIN_FULL_5 | The state indicates that the ice container is full and that ice making has been stopped |
| CLEAN_6 | Ice machine is running through the cleaning steps |
| OFF_7 | Ice machine is switched off |
| SLEEP_MODE_8 | Power failure detected, system clock continues to run |
| STANDBY_9 | State after a temperature sensor error |
| SAFE_MODE_10 | Continue with ice making following an error |
| WATER_OUTAGE_11 | State with a lack of water |
| HPCO_DELAY_ACTIVE_12 | Maintenance state when the overpressure switch is activated and no ice is made for xx minutes |
| CURTAIN_OPEN_13 | Curtain was opened because there is an ice slab between the evaporator and the container. |
| PRODUCTION_TEST_14 | Ice machine is in the function test mode (at the manufacturer) |
| SAFE_MODE_PRECHILL_15 | Like the PRE_CHILL_2 state, but after a SAFE_MODE_10 state |
| SAFE_MODE_FREEZE_16 | Like the FREEZE_3 state, but after a SAFE_MODE_10 state |
| SAFE_MODE_HARVEST_17 | Like the HARVEST_4 state, but after a SAFE_MODE_10 state |
| SAFE_MODE_FULL_BIN_18 | Like the BIN_FULL_5 state, but after a SAFE_MODE_10 state |