14.2.3 ObjectType description

14.2.3.1 CurrentState variable

The CurrentState variable represents the current operating state of a Coffee Machine.

The data type for the CoffeeMachineModeEnumeration is defined in section 14.5.2.

14.2.3.2 BoilerPressureWater variable

The BoilerPressureWater variable represents the pressure of the water boiler in Pa. The pressure of the water boiler can only be read.

The EngineeringUnit property of the AnalogItemType has the value Pa. The value for the EURange property is device-specific.

14.2.3.3 BoilerPressureSteam variable

The BoilerPressureSteam variable represents the pressure of the steam boiler in Pa. The pressure of the steam boiler is not available in every machine. The pressure of the steam boiler can only be read.

The EngineeringUnit property of the AnalogItemType has the value Pa. The value for the EURange property is device-specific.

14.2.3.4 BoilerTempWater variable

This variable represents the temperature in the water boiler in °C. The temperature of the water boiler can only be read.

The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.

14.2.3.5 BoilerTempSteam variable

The BoilerTempSteam variable represents the temperature of the steam boiler in °C. The temperature of the steam boiler is not available in every machine. The temperature of the steam boiler can only be read.

The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.

14.2.3.6 SystemClean variable

The SystemClean variable represents the time in UTC format at which the system cleaning was last carried out. The time can only be read.

14.2.3.7 TotalBrew_<No.> variables

The TotalBrew_<No.> variables represent the number of brews per brewer. At least one brewer exists. Further brewers are named with ascending numbers. The counters can only be read.

14.2.3.8 TotalMix variable

The TotalMix variables represent the number of cycles of the mixer. The number of mixer cycles can only be read.

14.2.3.9 GrinderRuntime_<No.> variables

The GrinderRuntime_<No.> variables represent the running times of the grinders in seconds. At least one grinder exists. Further grinders are named with ascending numbers. The running times can only be read.

The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.