This variable describes the state of the device, e.g. heating up or frying.
The data type for the FryingPanModeEnumeration is defined in section 7.4.1.
This variable describes the cooking level with which heating up is to take place.
The value is used only in the Cook and CookSlow ProgramMode.
This variable contains the set temperature to which heating up is to take place. With pressure cooking the set pressure is calculated on the basis of the set temperature.
The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.
This variable describes the currently measured temperature.
The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.
This variable describes the set process time in seconds.
The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.
This variable describes the remaining process time in seconds.
The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.
This variable describes the set core temperature.
The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.
This variable describes the currently measured core temperature.
The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.
This variable describes the state of the signal output. In addition to the on and off states, the "Signal was acknowledged" state is also saved.
The data type for the SignalModeEnumeration is defined in 7.4.2.
This variable describes the currently measured pressure in the pan.
The EngineeringUnit property of the AnalogItemType has the value mbar. The value for the EURange property is device-specific.
This variable describes whether the lid is locked.