The CookingZoneParameterType is formally defined in Table 59.

Table 59 — CookingZoneParameterType definition

Attribute

Value

BrowseName

CookingZoneParameterType

IsAbstract

False

References

NodeClass

BrowseName

DataType

TypeDefinition

ModellingRule AccessLevel

Subtype of KitchenDeviceParameterType

HasComponent

Variable

CurrentState

CurrentStateEnumeration

BaseDataVariableType

O, R

HasComponent

Variable

CookingZoneName

String

BaseDataVariableType

O, R

HasComponent

Variable

ActualTemperature

Float

AnalogItemType

O, R

HasComponent

Variable

SetTemperature

Float

AnalogItemType

O, R

HasComponent

Variable

ActualProcessTime

Int32

AnalogItemType

O, R

HasComponent

Variable

SetPowerValue

Int32

AnalogItemType

O, R

HasComponent

Variable

ActualPower

Float

AnalogItemType

O, R

HasComponent

Variable

IsPanDetected

Boolean

BaseDataVariableType

O, R

HasComponent

Variable

NominalPower

Int32

AnalogItemType

M, R

This variable describes the state of the device, e.g. standby or power output.

The data type for the CurrentStateEnumeration is defined in section 17.4.1.

This variable describes, for example, the position of the cooking zone, such as left cooking zone, right cooking zone.

This variable describes the currently measured cooking zone temperature.

The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.

This variable contains the set temperature to which the cooking zone is to be heated.

The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.

This variable contains the operating time of the cooking zone.

The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.

This variable contains the set value for the power.

The EngineeringUnit property of the AnalogItemType has the value % and the EURange property has the minimum value 0 and the maximum value 100.

The ActualPower variable returns the current power of the cooking zone.

The EngineeringUnit property of the AnalogItemType has the value W. The value for the EURange property is device-specific.

This variable describes whether a pan has been detected on the cooking zone.

This variable contains the nominal power of the cooking zone.

The EngineeringUnit property of the AnalogItemType has the value W. The value for the EURange property is device-specific.