12.8 SamplingIntervalDiagnosticsDataType

This structure contains diagnostic information about the sampling rates currently used by the Server. Its elements are defined in Table 224.

Table 224– SamplingIntervalDiagnosticsDataType Structure

Name

Type

Description

SamplingIntervalDiagnosticsDataType

structure

samplingInterval

Duration

The sampling interval in milliseconds.

monitoredItemCount

UInt32

The number of MonitoredItemsbeing sampled at this sample rate.

maxMonitoredItemCount

UInt32

The maximum number of MonitoredItemsbeing sampled at this sample rate at the same time since the server was started (restarted).

disabledMonitoredItemCount

UInt32

The number of MonitoredItemsat this sample rate whose sampling is currently disabled.

Its representation in the AddressSpaceis defined in Table 225.

Table 225– SamplingIntervalDiagnosticsDataType definition

Attributes

Value

BrowseName

SamplingIntervalDiagnosticsDataType

IsAbstract

FALSE

References

NodeClass

BrowseName

DataType

TypeDefinition

ModellingRule

Subtype of the Structure DataTypedefined in Table 182.

Conformance Units

Base Info ServerType