12.21 SystemStateDataType
This DataType is an enumeration that identifies the pre-defined SEMI E10 states as described in Section 11.6. Its values are defined in Table 155.
| Value | Description |
| PRD_1 | Production: The vision system is currently working on a job. |
| SBY_2 | Stand by: The vision system is ready to accept a command but is currently not executing a job. It could for example be waiting for a Start command or a user input. |
| ENG_3 | Engineering: The vision system is not working and not ready to accept a command because a user is currently working on the system. This could be for editing a recipe or changing the system configuration. |
| SDT_4 | Scheduled downtime: The vision system is not available for production and this was planned in advance. This could be for cleaning, maintenance or calibration works. |
| UDT_5 | Unscheduled downtime: The vision system is not available for production due to failure and repair. This covers all kinds of error states that might occur during operation. |
| NST_6 | Nonscheduled time: The vision system is not working because no production was scheduled. This also covers things like operator training on the system. |