7.31 ThermalConductivitySignalType

The ThermalConductivitySignalType provides ObjectType to add thermal conductivity measurement specific variables. It is formally defined in Table 168.

Table 168 – ThermalConductivitySignalType definition
Attribute Value
BrowseNameThermalConductivitySignalType
IsAbstractFalse
References NodeClass BrowseName DataType TypeDefinition Other
Subtype of AnalyticalSignalType defined in 7.27, i.e. inheriting the InstanceDeclarations of that Node
0:HasComponentObjectSignalConditionSet0:BaseObjectTypeO
Conformance Units
PA-DIM ThermalConductivitySignalType

SignalConditionSet is a container object for the condition parameters of the signal. It is inherited from AnalogSignalType and has an additional interface reference to IThermalConductivitySignalConditionSetType to add thermal conductivity signal specific condition variables.

The components of ThermalConductivitySignalType have additional references which are defined in Table 169.

Table 169 – ThermalConductivitySignalType additional References
SourceBrowsePath Reference Type Is Forward TargetBrowsePath
SignalConditionSet0:HasInterfaceTrueIThermalConductivitySignalConditionSetType
0:HasDictionaryEntryTrue 3:0112/2///61987#ABA968#004

The components of ThermalConductivitySignalType have additional subcomponents which are defined in Table 170.

Table 170 – ThermalConductivitySignalType additional subcomponents
BrowsePath References NodeClass BrowseName DataType TypeDefinition Others
Applied from IThermalConductivitySignalConditionSetType
SignalConditionSet0:HasComponentVariableSampleTemperature0:Float0:AnalogUnitTypeO

The child Nodes of the ThermalConductivitySignalType have additional Attribute values defined in Table 171.

Table 171 – ThermalConductivitySignalType Attribute values for child Nodes
BrowsePath Value Attribute
0.0
NamespaceUri: http://www.opcfoundation.org/UA/units/cdd/IEC62720
UnitId: 705741427
DisplayName: °C
Description: degree Celsius