7.1.25 IAmperometricGasDetectorSignalConditionSetType

The IAmperometricGasDetectorSignalConditionSetType provides the interface to Amperometric Electrochemical signal specific condition variables and is formally defined in Table 85

Table 85 – IAmperometricGasDetectorSignalConditionSetType definition
Attribute Value
BrowseNameIAmperometricGasDetectorSignalConditionSetType
IsAbstractTrue
References NodeClass BrowseName DataType TypeDefinition Other
Subtype of 0:BaseInterfaceType defined in OPC 10000-5, i.e. inheriting the InstanceDeclarations of that Node
0:HasComponentVariableSensingElementTemperature 0:Float0:AnalogUnitTypeO
0:HasPropertyVariableSensorNextCalibrationFixed0:Float0:PropertyTypeO
0:HasPropertyVariableSensorNextCalibrationDynamic0:Float0:PropertyTypeO
0:HasPropertyVariablePowerOnDurationSensor0:Duration0:PropertyTypeO
0:HasPropertyVariableSensingElementResidualLife0:Float0:PropertyTypeO
0:HasPropertyVariableRelativeGasFlowRate0:Float0:PropertyTypeO
0:HasPropertyVariableConsumedSensorCapacity0:Float0:PropertyTypeO
0:HasPropertyVariableRangeExceedancePeakValue0:Float0:PropertyTypeO
0:HasPropertyVariableRangeExceedanceDuration0: Duration0:PropertyTypeO
0:HasPropertyVariableSensingElementResidualSensitivity0:Float0:PropertyTypeO
Conformance Units
PA-DIM AmperometricGasDetectorSignalType
PA-DIM AmperometricGasDetectorSignalType SensorNextCalibrationFixed
PA-DIM AmperometricGasDetectorSignalType SensorNextCalibrationDynamic
PA-DIM AmperometricGasDetectorSignalType PowerOnDurationSensor
PA-DIM AmperometricGasDetectorSignalType SensingElementResidualLife
PA-DIM AmperometricGasDetectorSignalType RelativeGasFlowRate
PA-DIM AmperometricGasDetectorSignalType ConsumedSensorCapacity
PA-DIM AmperometricGasDetectorSignalType RangeExceedance
PA-DIM AmperometricGasDetectorSignalType SensingElementResidualSensitivity

The components of IAmperometricGasDetectorSignalConditionSetType have additional references which are defined in Table 86.

Table 86 – IAmperometricGasDetectorSignalConditionSetType additional References
SourceBrowsePath Reference Type Is Forward TargetBrowsePath
SensingElementTemperature 0:HasDictionaryEntryTrue 3:0112/2///61987#ABP565#001
SensorNextCalibrationFixed0:HasDictionaryEntryTrue 3:0112/2///61987#ABQ016#001
SensorNextCalibrationDynamic0:HasDictionaryEntryTrue 3:0112/2///61987#ABQ017#001
PowerOnDurationSensor0:HasDictionaryEntryTrue 3:0112/2///61987#ABQ010#001
SensingElementResidualLife0:HasDictionaryEntryTrue 3:0112/2///61987#ABP584#001
RelativeGasFlowRate0:HasDictionaryEntryTrue 3:0112/2///61987#ABQ011#001
ConsumedSensorCapacity0:HasDictionaryEntryTrue 3:0112/2///61987#ABQ018#001
RangeExceedancePeakValue0:HasDictionaryEntryTrue 3:0112/2///61987#ABQ019#001
RangeExceedanceDuration0:HasDictionaryEntryTrue 3:0112/2///61987#ABQ020#001
SensingElementResidualSensitivity0:HasDictionaryEntryTrue 3:0112/2///61987#ABQ040#001

The child Nodes of the IAmperometricGasDetectorSignalConditionSetType have additional Attribute values defined in Table 87.

Table 87 – IAmperometricGasDetectorSignalConditionSetType Attribute values for child Nodes
BrowsePath Value Attribute
SensingElementTemperature 0
SensorNextCalibrationFixed0
SensorNextCalibrationDynamic0
PowerOnDurationSensor0
SensingElementResidualLife1
RelativeGasFlowRate0
ConsumedSensorCapacity0
RangeExceedancePeakValue0
RangeExceedanceDuration0
SensingElementResidualSensitivity1