The IZirconiumDioxideSignalConditionSetType provides the interface to Zirconium dioxide measurement signal specific condition variables and is formally defined in Table 58.
Table 58 – IZirconiumDioxideSignalConditionSetType definition
Attribute |
Value |
||||
BrowseName |
IZirconiumDioxideSignalConditionSetType |
||||
IsAbstract |
True |
||||
References |
NodeClass |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of 0:BaseInterfaceType defined in OPC 10000-5, i.e. inheriting the InstanceDeclarations of that Node |
|||||
0:HasComponent |
Variable |
RelativeHeatOutput |
0:Float |
0:DataItemType |
O |
0:HasComponent |
Variable |
SensingElementTemperature |
0:Float |
0:AnalogUnitType |
O |
0:HasComponent |
Variable |
SampleGasVolumeFlow |
0:Float |
0:AnalogUnitType |
O |
Conformance Units |
|||||
PA-DIM ZirconiumDioxideSignalType |
|||||
PA-DIM ZirconiumDioxideSignalType RelativeHeatOutput |
|||||
PA-DIM ZirconiumDioxideSignalType SampleGasVolumeFlow |
RelativeHeatOutput is defined by IRDI as ABP585#001 which states “relative heat output refered to the maximum heat output to keep the sensor at its setpoint temperature during operation”.
SensingElementTemperature is defined by IRDI as ABP565#001 which states “temperature measured at a sensing element”.
SampleGasVolumeFlow is defined by IRDI as ABP562#001 which states “volume flow of a sample gas through a detection system”.
The components of IZirconiumDioxideSignalConditionSetType have additional references which are defined in Table 59.
Table 59 – IZirconiumDioxideSignalConditionSetType additional References
SourceBrowsePath |
Reference Type |
Is Forward |
TargetBrowsePath |
||
RelativeHeatOutput |
0:HasDictionaryEntry |
True |
3:0112/2///61987#ABP585#001 |
||
SensingElementTemperature |
0:HasDictionaryEntry |
True |
3:0112/2///61987#ABP565#001 |
||
|
0:HasDictionaryEntry |
True |
|||
SampleGasVolumeFlow |
0:HasDictionaryEntry |
True |
3:0112/2///61987#ABP562#001 |
||
|
0:HasDictionaryEntry |
True |
The child Nodes of the IZirconiumDioxideSignalConditionSetType have additional Attribute values defined in Table 60.
Table 60 – IZirconiumDioxideSignalConditionSetType Attribute values for child Nodes
BrowsePath |
Value Attribute |
||
RelativeHeatOutput |
0.0 |
||
SensingElementTemperature |
0.0 |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefactUnitId: 4408652DisplayName: °CDescription: degree Celsius |
||
SampleGasVolumeFlow |
0.0 |
||
|
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefactUnitId: 4535090DisplayName: l/hDescription: litre per hour |