7.11.4 PtAnalogOutputElectricalAttributesType ObjectType Definition

7.11.4.1 Overview

The PtAnalogOutputElectricalAttributesType provides analog output asset attributes and is formally defined in Table 132.

Table 132 – PtAnalogOutputElectricalAttributesType Definition
Attribute Value
BrowseNamePtAnalogOutputElectricalAttributesType
IsAbstractFalse
References Node Class BrowseName DataType TypeDefinition Other
Subtype of the PtCommonAssetAttributesType defined in chapter 7.11
0:HasComponentVariableAnalogOutputElectricalType0:UInt160:MultiStateValueDiscreteTypeO, RO
0:HasPropertyVariableNumberOfChannels0:UInt160:PropertyTypeO, RO
0:HasComponentVariableLoadResistance0:Float0:AnalogUnitTypeO, RO
0:HasComponentVariableFrequencyRange0:Range0:BaseDataVariableTypeO, RO
Conformance Units
Powertrain Attributes Information
7.11.4.2 Object Description

AnalogOutputElectricalType provides the used analog output(s). The values of the MultiStateValueDiscreteType variable are defined in Table 133 and shall be used. The values 0-199 are reserved for future extensions of this specification. The values 200-299 shall be used for vendor-specific extensions of this variable.

Table 133 – PtAnalogOutputElectricalAttributesType Attribute values for child Nodes
BrowsePath Value Attribute Description Attribute
[
{
"Value": 0,
"DisplayName": "VOLTAGE_0-10V",
"Description": "Voltage range 0-10 volt"
},
{
"Value": 1,
"DisplayName": "VOLTAGE_-10-10V",
"Description": "Voltage range -10-10 volt"
},
{
"Value": 2,
"DisplayName": "CURRENT_0-20MA",
"Description": "Current range 0-20 milliampere"
},
{
"Value": 3,
"DisplayName": "CURRENT_4-20MA",
"Description": "Current range 4-20 milliampere"
},
{
"Value": 4,
"DisplayName": "TEMPERATURE_PT1000",
"Description": "PT1000 temperature sensor"
},
{
"Value": 5,
"DisplayName": "TEMPERATURE_PT100",
"Description": "PT100 temperature sensor"
},
{
"Value": 6,
"DisplayName": "TEMPERATURE_KTY",
"Description": "KTY temperature sensor"
},
{
"Value": 7,
"DisplayName": "TEMPERATURE_KTY84",
"Description": "KTY84 temperature sensor"
},
{
"Value": 8,
"DisplayName": "TEMPERATURE_PTC",
"Description": "PTC temperature sensor"
},
{
"Value": 9,
"DisplayName": "VOLTAGE",
"Description": "Other voltage interface"
},
{
"Value": 10,
"DisplayName": "CURRENT",
"Description": "Other current interface"
},
{
"Value": 11,
"DisplayName": "TEMPERATURE",
"Description": "Other temperature interface"
},
{
"Value": 12,
"DisplayName": "CONFIGURABLE",
"Description": "Configurable"
}
]

NumberOfChannels provides the number of channels of the analog output representation.

LoadResistance provides the minimum value of the load resistance. The unit shall be ohm [Ω].

FrequencyRange provides the range of frequencies usable for the analog output. The unit shall be hertz [Hz].

The attributes of the PtAnalogOutputElectricalAttributesType have additional subattributes which are defined in Table 134.

Table 134 – PtAnalogOutputElectricalAttributesType additional subattributes
BrowsePath References NodeClass BrowseName DataType TypeDefinition Others
FrequencyRange0:HasPropertyVariable0:EngineeringUnitsEUInformation0:PropertyTypeM