7.10.2.1 Overview

The PtElectronicOverloadRelayAttributesType provides the common asset attributes of a contactor and is formally defined in Table 113. Additional attributes can be found in IEC Common Data Dictionary (CDD) 62683DB.

Table 113 – PtElectronicOverloadRelayAttributesType Definition
Attribute Value
BrowseNamePtElectronicOverloadRelayAttributesType
IsAbstractFalse
References Node Class BrowseName DataType TypeDefinition Other
Subtype of the PtAssetAttributesType defined in chapter 7.7
0:HasPropertyVariableOverloadCurrentSettingRange0:Range0:PropertyTypeM, RO
0:HasComponentVariableTripClass0:UInt160:MultiStateValueDiscreteTypeM, RO
0:HasPropertyVariableVoltageRated0:UInt160:PropertyTypeM, RO
0:HasPropertyVariableNumberofAuxiliaryContactsNC0:UInt160:PropertyTypeM, RO
0:HasPropertyVariablePhaseLossSensitiveSupported0:Boolean0:PropertyTypeM, RO
0:HasPropertyVariableJamDetectionSupported0:Boolean0:PropertyTypeM, RO
0:HasPropertyVariableStallDetectionSuported0:Boolean0:PropertyTypeM, RO
0:HasPropertyVariableGroundEarthFaultDetectionSupported0:Boolean0:PropertyTypeM, RO
Conformance Units
Powertrain Attributes Information