7.11.2 PtAmbientAttributesType ObjectType Definition

7.11.2.1 Overview

The PtAmbientAttributesType provides related ambient conditions in which the equipment is guaranteed to function and is formally defined in Table 129.

Table 129 – PtAmbientAttributesType Definition
Attribute Value
BrowseNamePtAmbientAttributesType
IsAbstractFalse
References Node Class BrowseName DataType TypeDefinition Other
Subtype of the PtCommonAssetAttributesType defined in chapter 7.5.1
0:HasComponentVariableTemperatureMin0:Float0:AnalogUnitTypeM, RO
0:HasComponentVariableTemperatureMax0:Float0:AnalogUnitTypeM, RO
0:HasComponentVariableHumidityMin0:Float0:AnalogUnitTypeO, RO
0:HasComponentVariableHumidityMax0:Float0:AnalogUnitTypeO, RO
0:HasComponentVariablePressureMin0:Float0:AnalogUnitTypeO, RO
0:HasComponentVariablePressureMax0:Float0:AnalogUnitTypeO, RO
0:HasComponentVariableAltitudeMax0:Float0:AnalogUnitTypeO, RO
Conformance Units
Powertrain Attributes Information
7.11.2.2 Object Description

TemperatureMin provides the supported minimum temperature value of an asset. The unit shall be celsius [°C].

TemperatureMax provides the supported maximum temperature value of an asset. The unit shall be celsius [°C] without derating.

HumidityMin provides supported minimum humidity value of an asset without condensation conforming to IEC 61800-5-1. The unit shall be percent [%].

HumidityMax provides supported maximum humidity value of an asset without condensation conforming to IEC 61800-5-1. The unit shall be percent [%].

PressureMin indicates the minimum pressure value for which the asset is designed. The unit shall be pascal [PA].

PressureMax indicates the maximum pressure value for which the asset is designed. The unit shall be pascal [PA].

AltitudeMax indicates the maximum altitude value above sea level for which the asset is designed. The unit shall be meter [m] without derating.