7.11.2.1 Overview
The PtAmbientAttributesType provides related ambient conditions in which the equipment is guaranteed to function and is formally defined in Table 129.
Table 129 – PtAmbientAttributesType Definition
|
Attribute
|
Value
|
| BrowseName | PtAmbientAttributesType |
| IsAbstract | False |
|
References
|
Node Class
|
BrowseName
|
DataType
|
TypeDefinition
|
Other
|
|---|
| Subtype of the PtCommonAssetAttributesType defined in chapter 7.5.1 |
| 0:HasComponent | Variable | TemperatureMin | 0:Float | 0:AnalogUnitType | M, RO |
| 0:HasComponent | Variable | TemperatureMax | 0:Float | 0:AnalogUnitType | M, RO |
| 0:HasComponent | Variable | HumidityMin | 0:Float | 0:AnalogUnitType | O, RO |
| 0:HasComponent | Variable | HumidityMax | 0:Float | 0:AnalogUnitType | O, RO |
| 0:HasComponent | Variable | PressureMin | 0:Float | 0:AnalogUnitType | O, RO |
| 0:HasComponent | Variable | PressureMax | 0:Float | 0:AnalogUnitType | O, RO |
| 0:HasComponent | Variable | AltitudeMax | 0:Float | 0:AnalogUnitType | O, RO |
|
Conformance Units
|
|---|
| Powertrain Attributes Information |