9.4.6 RioFaAnalogInputConfigVariableType

The RioFaAnalogInputConfigVariableType represents the configuration of an analog RIO Input Channel according to RIO FA.

Table 74 – RioFaAnalogInputConfigVariableType Definition
Attribute Value
BrowseNameRioFaAnalogInputConfigVariableType
IsAbstractFalse
ValueRank-1 (-1 = Scalar)
DataTypeRioFaAnalogInputConfigDataType
References Node Class BrowseName DataType TypeDefinition Other
Subtype of the BaseDataVariableType defined in OPC 10000-5.
0:HasPropertyVariableDamping0:Float0:PropertyTypeO, RO
0:HasPropertyVariableSignalTypeRioSignalTypeEnumeration0:PropertyTypeO, RO
0:HasPropertyVariableWireCheckEnabled0:Boolean0:PropertyTypeO, RO
0:HasPropertyVariableSupplyVoltageCheckEnabled0:Boolean0:PropertyTypeO, RO
0:HasPropertyVariableSubstitutePolicyRioSubstitutePolicyEnumeration0:PropertyTypeO, RO
0:HasPropertyVariableSubstituteValueRioAnalogDataType0:PropertyTypeO, RO
Conformance Units
PNRIO Channel Objects