7.2.4.6 RioFaDigitalInputChannelType

The RioFaDigitalInputChannelType provides access to the data of a discrete RIO Input Channel according to RIOforFA.

Table 49 – RioFaDigitalInputChannelType
Attribute Value
BrowseNameRioFaDigitalInputChannelType
IsAbstractFalse
References Node Class BrowseName DataType TypeDefinition Other
Subtype of the RioChannelType.
0:HasComponentVariableProcessValueRioFaDigitalProcessValueDataTypeRioFaDigitalProcessValueVariableTypeM, RO
0:HasComponentVariableSignalValue0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableConfigRioFaDigitalInputConfigDataTypeRioFaDigitalInputConfigVariableTypeM, RO
Conformance Units
PNRIO Channel Objects

The ProcessValue Variable contains the digital Input value for a Controller.

The SignalValue Variable contains the input signal value obtained by reading the input signal through the signal coupling in the Transducer.

The Config Variable contains the configuration properties available for the RIO Channel. See the definition of the RioFaDigitalInputConfigVariableType (see chapter 9.4.2).