8.110 SafetyValveOrFittingType
A safety valve or fitting.
| Attribute | Value | |||
| BrowseName | SafetyValveOrFittingType | |||
| IsAbstract | False | |||
| References | NodeClass | BrowseName |
DataType /
TypeDefinition | Other |
|---|---|---|---|---|
| Subtype of PipingComponentType | ||||
| 0:HasComponent | Variable | PositionNumberAssignmentClass | 0:String 0:BaseDataVariableType | O |
| 0:HasComponent | Variable | FlowOutPipingClassCodeAssignment Class | 0:String 0:BaseDataVariableType | O |
| 0:HasComponent | Variable | LocationRegistrationNumber AssignmentClass | 0:String 0:BaseDataVariableType | O |
| 0:HasComponent | Variable | FlowInPipingClassCodeAssignmentClass | 0:String 0:BaseDataVariableType | O |
| 0:HasComponent | Variable | SetPressureLow | 0:Double 0:AnalogUnitType | O |
| 0:HasComponent | Variable | SetPressureHigh | 0:Double 0:AnalogUnitType | O |
PositionNumberAssignmentClass – The position number of the SafetyValveOrFitting.
FlowOutPipingClassCodeAssignmentClass – The code of the piping class at the flow out side of SafetyValveOrFitting.
LocationRegistrationNumberAssignmentClass – The location registration number of the SafetyValveOrFitting.
FlowInPipingClassCodeAssignmentClass – The code of the piping class at the flow in side of SafetyValveOrFitting.
SetPressureLow – The low pressure at which the SafetyValveOrFitting is activated.
SetPressureHigh – The high pressure at which the SafetyValveOrFitting is activated.