8.3 ExplosionProtectionOptionSet

The ExplosionProtectionOptionSet defines flags for the category of explosion protection for devices according to EU Directive 2014/34/EU (ATEX) in Table 118.

Table 118 – ExplosionProtectionOptionSet Values
Value Bit No. Description
M10This category is intended for use in underground mines and their surface installations which may be endangered by firedamp and/or combustible dust. Category 1 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a very high level of safety. (2014/34/EU)
M21This category is intended for use in underground mines and their surface installations which may be endangered by firedamp and/or combustible dust. Category 2 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a high level of safety. (2014/34/EU)
1G2Devices in this category are intended for use in areas in which an explosive atmosphere consisting of a mixture of air and gases, vapors or mists is present. Category 1 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a very high level of safety. (2014/34/EU)
2G3Devices in this category are intended for use in areas in which an explosive atmosphere consisting of a mixture of air and gases, vapors or mists is present. Category 2 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a high level of safety. (2014/34/EU)
3G4Devices in this category are intended for use in areas in which an explosive atmosphere consisting of a mixture of air and gases, vapors or mists is present. Category 3 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a normal level of safety. (2014/34/EU)
1D5Devices in this category are intended for use in areas in which an explosive atmosphere consisting of a mixture of air and dust is present. Category 1 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a very high level of safety. (2014/34/EU)
2D6Devices in this category are intended for use in areas in which an explosive atmosphere consisting of a mixture of air and dust is present. Category 2 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a high level of safety. (2014/34/EU)
3D7Devices in this category are intended for use in areas in which an explosive atmosphere consisting of a mixture of air and dust is present. Category 3 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a normal level of safety. (2014/34/EU)

The ExplosionProtectionOptionSet representation in the AddressSpace is formally defined in Table 119.

Table 119 – ExplosionProtectionOptionSet Definition
Attribute Value
BrowseNameExplosionProtectionOptionSet
IsAbstractFalse
References NodeClass BrowseName DataType TypeDefinition Other
Subtype of the OptionSet DataType defined in OPC 10000-5
0:HasPropertyVariableOptionSetValues0:LocalizedText[]0:PropertyTypeM, RO