7.42 OutletConnectionDesignType ObjectType Definition
The OutletConnectionDesignType extends its supertype by Pump outlet connection specific Variables and is formally defined in Table 92.
| Attribute | Value | ||||
| BrowseName | OutletConnectionDesignType | ||||
| IsAbstract | False | ||||
| References | Node Class | BrowseName | DataType | TypeDefinition | Other |
|---|---|---|---|---|---|
| Subtype of the ConnectionDesignType defined in 7.40, i.e. inheriting the InstanceDeclarations of that Node. | |||||
| 0:HasComponent | Variable | MaximumAllowableOutletPressure | 0:Double | 0:BaseAnalogType | O, RO |
| 0:HasComponent | Variable | MinimumAllowableOutetPressure | 0:Double | 0:BaseAnalogType | O, RO |
| 0:HasComponent | Variable | OutletAreaOfThePump | 0:Double | 0:BaseAnalogType | O, RO |
| 0:HasComponent | Variable | ReliefValveAccumulationPressure | 0:Double | 0:BaseAnalogType | O, RO |
| 0:HasComponent | Variable | ReliefValveBackPressure | 0:Double | 0:BaseAnalogType | O, RO |
| 0:HasComponent | Variable | ReliefValveReseatPressure | 0:Double | 0:BaseAnalogType | O, RO |
| 0:HasComponent | Variable | ReliefValveSetPressure | 0:Double | 0:BaseAnalogType | O, RO |
The InstanceDeclarations of the OutletConnectionDesignType have additional Attributes defined in Table 93. The Variables and the associated Descriptions are based on the standard DIN EN ISO 17769-1.
| BrowsePath | Value Attribute | Description Attribute |
| MaximumAllowableOutletPressure | Highest value of outlet pressure at which the pump or component is capable of functioning on the basis of the materials used. | |
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal | ||
| MinimumAllowableOutetPressure | Lowest value of outlet pressure at which the pump or component is capable of functioning on the basis of the materials used. | |
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal | ||
| OutletAreaOfThePump | Free cross-sectional area of the orifice in the outlet connection of the pump. | |
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067851 DisplayName: m² Description: square metre | ||
| ReliefValveAccumulationPressure | Outlet pressure at which the relief valve will pass the total pump flow. | |
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal | ||
| ReliefValveBackPressure | Pressure at the outlet of the relief valve when the valve is closed. | |
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal | ||
| ReliefValveReseatPressure | Outlet pressure at which the relief valve will close after passing the total pump flow. | |
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal | ||
| ReliefValveSetPressure | Outlet pressure at which the relief valve begins to open. | |
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |