7.22 ImplementationType ObjectType Definition

The ImplementationType provides static Variables for preconfiguring a Pump for the process in which the Pump is to be used and is formally defined in Table 51.

Table 51 – ImplementationType Definition
Attribute Value
BrowseNameImplementationType
IsAbstractFalse
References Node Class BrowseName DataType TypeDefinition Other
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node.
0:HasComponentVariableAtmosphericPressure0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariableDensity0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariableDynamicViscosity0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariableHeightOfTheInletManometer0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariableHeightOfTheNpshDatumPlane0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariableHeightOfTheOutletManometer0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariableHydraulicEfficiency0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariableInstallationTotalHead0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariableKinematicViscosity0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariableMaximumAllowableFlow0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariableMaximumDynamicSealingPressure0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariableRatedMeanVelocityAtInletAreaOfTheInstallation0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariableRatedMeanVelocityAtOutletAreaOfTheInstallation0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariableMechanicalEfficiency0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariableMinimumAllowableFlow0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariableMinimumAllowableStableFlow0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariableNetPositiveSuctionHeadAvailable0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariableOverallEfficiency0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariablePumpBestEfficiency0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariablePumpEfficiency0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariablePumpMechanicalPowerLosses0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariablePumpRatedPowerInput0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariablePumpTotalHead0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariableRatedDifferentialPressure0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariableRatedFlow0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariableRatedSpeed0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariableTotalHeadAtInletAreaOfTheInstallation0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariableTotalHeadAtOutletAreaOfTheInstallation0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariableUsefulLife0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariableValveSeatVelocity0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariableValveSpillVelocity0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariableVaporPressureOfThePumpedLiquid0:Double0:BaseAnalogTypeO, RW
0:HasComponentVariableVolumetricEfficiency0:Double0:BaseAnalogTypeO, RW

The InstanceDeclarations of the ImplementationType have additional Attributes defined in Table 52. The Variables and the associated Descriptions are based on the standards DIN EN ISO 17769-1 and DIN EN 13306.

Table 52 – ImplementationType Attribute values for child Nodes
BrowsePath Value Attribute Description Attribute
AtmosphericPressureMean absolute pressure of the atmosphere measured at the place of installation (2.1.1.3) of the pump

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

DensityVolumetric mass at a stated temperature

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4934993

DisplayName: kg/m³

Description: kilogram per cubic metre

DynamicViscosityRatio of the shear stress to the shear velocity acting in a liquid subjected to a plane shear motion

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4404789

DisplayName: Pa·s

Description: pascal second

HeightOfTheInletManometerHeight of the zero or center position of the inlet manometer, or other point as defined by the manometer calibration

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

HeightOfTheNpshDatumPlaneDifference between the NPSH datum plane and the reference plane

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

HeightOfTheOutletManometerHeight of the zero or center position of the outlet manometer, or other point as defined by the manometer calibration

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

HydraulicEfficiencyProportion of pump available power input, Pa, which is delivered as pump power output, Pu, after satisfying the losses resulting from friction due to the relative motion of internal surfaces and internal leakage

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 20529

DisplayName: %

Description: percent

InstallationTotalHeadDifference between the total head at the outlet side of the installation and the total head at the inlet side of the installation

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

KinematicViscosityRatio of the dynamic viscosity to the density of the pumped liquid

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 21300

DisplayName: m²/s

Description: square metre per second

MaximumAllowableFlowGreatest rate of flow that the pump can be expected to deliver continuously without risk of internal damage when operated at the rated speed and on the liquid for which it was supplied

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067091

DisplayName: m³/s

Description: cubic metre per second

MaximumDynamicSealingPressureHighest pressure expected at the shaft seals during any specified operating condition and during startup and shutdown

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

RatedMeanVelocityAtInletAreaOfTheInstallationRated flow at the inlet area of the installation divided by the inlet area of the installation

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067859

DisplayName: m/s

Description: metre per second

RatedMeanVelocityAtOutletAreaOfTheInstallationRated flow at the outlet area of the installation divided by the inlet area of the installation

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067859

DisplayName: m/s

Description: metre per second

MechanicalEfficiencyProportion of the pump power input, P, available after satisfying the mechanical power losses, PJ,ab, at given operating conditions

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 20529

DisplayName: %

Description: percent

MinimumAllowableFlowSmallest rate of flow that the pump can be expected to deliver continuously without risk of internal damage when operated at the rated speed and on the liquid for which it was supplied

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067091

DisplayName: m³/s

Description: cubic metre per second

MinimumAllowableStableFlowLowest flow at which the pump can operate without exceeding the noise and vibration limits imposed in the order

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067091

DisplayName: m³/s

Description: cubic metre per second

NetPositiveSuctionHeadAvailableMinimum NPSH available at the inlet area of the pump as determined by the conditions of the installation for a specified rate of flow

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

OverallEfficiencyProportion of the driver power input, Pmot, delivered as pump power output, Pu

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 20529

DisplayName: %

Description: percent

PumpBestEfficiencyGreatest value of pump efficiency obtained at given operating conditions

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 20529

DisplayName: %

Description: percent

PumpEfficiencyProportion of the pump power input, P, delivered as pump power output, Pu, at given operating conditions

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 20529

DisplayName: %

Description: percent

PumpMechanicalPowerLossesPower absorbed by friction in bearings and shaft seal at given operating conditions of the pump

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5723220

DisplayName: W

Description: watt

PumpRatedPowerInputPower required by the pump at the rated conditions

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5723220

DisplayName: W

Description: watt

PumpTotalHeadDifference between the total head at the outlet side of the pump and the total head at the inlet side of the pump

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

RatedDifferentialPressureDifferential pressure for the operating conditions at the guarantee point

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

RatedFlowRate of flow at the guarantee point

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067091

DisplayName: m³/s

Description: cubic metre per second

RatedSpeedNumber of revolutions of the pump in a given time required to meet the rated conditions

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4405559

DisplayName: s⁻¹

Description: reciprocal second

TotalHeadAtInletAreaOfTheInstallationHead observed at inlet area of the installation, corresponding to the sum of the height, pressure head and velocity head

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

TotalHeadAtOutletAreaOfTheInstallationHead observed at outlet area of the installation, corresponding to the sum of the height, pressure head and velocity head

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

UsefulLifeTime interval from first use until the instant when a limiting state is reached

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4740434

DisplayName: h

Description: hour

ValveSeatVelocityMean velocity of the flow through the valve seat at the specified operating conditions

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067859

DisplayName: m/s

Description: metre per second

ValveSpillVelocityMean velocity of the flow through the valve spill area

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067859

DisplayName: m/s

Description: metre per second

VaporPressureOfThePumpedLiquidAbsolute pressure at which the fluid vaporizes corresponding to the temperature of the liquid

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

VolumetricEfficiencyRatio of the actual delivered volume at maximum pressure to the geometric displacement volume

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 20529

DisplayName: %

Description: percent