7.45 OutletConnectionSystemRequirementsType ObjectType Definition
The OutletConnectionSystemRequirementsType provides static Variables for Pump outlet connection specific parameters of the process in which the Pump is to be used and is formally defined in Table 98.
| Attribute | Value | ||||
| BrowseName | OutletConnectionSystemRequirementsType | ||||
| IsAbstract | False | ||||
| References | Node Class | BrowseName | DataType | TypeDefinition | Other |
|---|---|---|---|---|---|
| Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node. | |||||
| 0:HasComponent | Variable | BackingPressure | 0:Double | 0:BaseAnalogType | O, RW |
The InstanceDeclarations of the OutletConnectionSystemRequirementsType have additional Attributes defined in Table 99. The Variables and the associated Descriptions are based on the standard DIN ISO 21360-1.
| BrowsePath | Value Attribute | Description Attribute |
| BackingPressure | Pressure at the outlet of a vacuum pump. | |
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal |