7.45 OutletConnectionSystemRequirementsType ObjectType Definition

The OutletConnectionSystemRequirementsType provides static Variables for Pump outlet connection specific parameters of the process in which the Pump is to be used and is formally defined in Table 98.

Table 98 – OutletConnectionSystemRequirementsType Definition
Attribute Value
BrowseNameOutletConnectionSystemRequirementsType
IsAbstractFalse
References Node Class BrowseName DataType TypeDefinition Other
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node.
0:HasComponentVariableBackingPressure0:Double0:BaseAnalogTypeO, RW

The InstanceDeclarations of the OutletConnectionSystemRequirementsType have additional Attributes defined in Table 99. The Variables and the associated Descriptions are based on the standard DIN ISO 21360-1.

Table 99 – OutletConnectionSystemRequirementsType Attribute values for child Nodes
BrowsePath Value Attribute Description Attribute
BackingPressurePressure at the outlet of a vacuum pump.

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal