7.41 InletConnectionDesignType ObjectType Definition

The InletConnectionDesignType extends its supertype by Pump inlet connection specific Variables and is formally defined in Table 90.

Table 90 – InletConnectionDesignType Definition
Attribute Value
BrowseNameInletConnectionDesignType
IsAbstractFalse
References Node Class BrowseName DataType TypeDefinition Other
Subtype of the ConnectionDesignType defined in 7.40, i.e. inheriting the InstanceDeclarations of that Node.
0:HasComponentVariableCriticalBackingPressure0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableInletAreaOfThePump0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableMaximumAllowableInletPressure0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableMaximumTolerableWaterVaporInletPressure0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableMaximumWorkingPressure0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableMinimumAllowableInletPressure0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableNetPositiveInletPressureRequired0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableWaterVaporCapacity0:Double0:BaseAnalogTypeO, RO

The InstanceDeclarations of the InletConnectionDesignType have additional Attributes defined in Table 91. The Variables and the associated Descriptions are based on the standards DIN EN ISO 17769-1, DIN 28426-1, ISO 3529-2 and ISO 21360-2.

Table 91 – InletConnectionDesignType Attribute values for child Nodes
BrowsePath Value Attribute Description Attribute
CriticalBackingPressureMaximum backing pressure for which the conditions are defined in the instruction manual or in a specific standard for the particular vacuum pump.

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

InletAreaOfThePumpFree cross-sectional area of the entry opening in the inlet connection of the pump.

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067851

DisplayName: m²

Description: square metre

MaximumAllowableInletPressureHighest value of inlet pressure at which the pump or component is capable of functioning on the basis of the materials used.

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

MaximumTolerableWaterVaporInletPressureThe highest water vapor inlet pressure at which a gas ballast pump, under normal ambient conditions, can pump and exhaust pure water vapor in continuous Operation.

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

MaximumWorkingPressureinstantaneous inlet pressure with adequate margin above the minimum liquid vapor pressure expected.

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

MinimumAllowableInletPressureLowest value of inlet pressure at which the pump or component is capable of functioning on the basis of the materials used.

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

NetPositiveInletPressureRequiredTotal inlet pressure required to ensure there is enough margin to maintain the minimum.

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

WaterVaporCapacityMass of water which can be conveyed by the pump without condensation per time.

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4600375

DisplayName: g/h

Description: gram per hour