7.20 DesignType ObjectType Definition

The DesignType provides static Variables for design properties, describing the limitations and working conditions of a Pump and is formally defined in Table 47.

Table 47 – DesignType Definition
Attribute Value
BrowseNameDesignType
IsAbstractFalse
References Node Class BrowseName DataType TypeDefinition Other
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node.
0:HasComponentVariableAdditionalFieldbuses0:String [128]0:DataItemTypeO, RO
0:HasComponentVariableBalancingRateOfFlow0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableBasePressure0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableClearanceVolume0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableClockwiseRotation0:Boolean0:TwoStateDiscreteTypeO, RO
0:HasComponentVariableControllable0:Boolean0:TwoStateDiscreteTypeO, RO
0:HasComponentVariableCool_DownTimeForAVaporJetPumpOrADiffusionPump0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableCounter_ClockwiseRotation0:Boolean0:TwoStateDiscreteTypeO, RO
0:HasComponentVariableCriticalSpeed0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableDeclarationOfConformity0:String0:DataItemTypeO, RO
0:HasComponentVariableDeclarationOfConformityAvailable0:Boolean0:TwoStateDiscreteTypeO, RO
0:HasComponentVariableDesignAxialLoad0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableDesignRadialLoad0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableDirectivesOfEUDeclarationOfConformityDeclarationOfConformityOptionSet0:DataItemTypeO, RO
0:HasComponentVariableDryCriticalSpeed0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableExplosionProtectionExplosionProtectionOptionSet0:DataItemTypeO, RO
0:HasComponentVariableGeometricalFlow0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableGeometricDisplacementVolume0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableHeadAtPeakPoint0:Double0:BaseAnalogTypeO, RO
0:HasComponentObjectInstallationNpshCurve0:FileTypeO
0:HasComponentVariableLeakageRateOfFlow0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableMaximumAllowableAmbientTemperature0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableMaximumAllowableCasingWorkingPressure0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableMaximumAllowableContinuousSpeed0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableMaximumAllowableHead0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableMaximumAllowableRelativeHumidity0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableMaximumAllowableTemperature0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableMaximumAllowableThroughput0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableMaximumAllowableWorkingPressure0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableMaximumAxialLoad0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableMaximumPumpPowerInput0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableMaximumRadialLoad0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableMaximumStaticSealingPressure0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableMeanTimebetweenFailures0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableMinimumAllowableAmbientTemperature0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableMinimumAllowableContinuousSpeed0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableMinimumAllowableHead0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableMinimumAllowableRelativeHumidity0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableMinimumAllowableTemperature0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableMinimumAllowableThermalFlow0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableMinimumContinuousStableFlow0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableMinimumContinuousThermalFlow0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableNetPositiveSuctionHeadRequired0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableNetPositiveSuctionHeadRequiredForADropOf3Percent0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableOfferedControlModesOfferedControlModesOptionSet0:DataItemTypeO, RO
0:HasComponentVariableOfferedFieldbusesOfferedFieldbusesOptionSet0:DataItemTypeO, RO
0:HasComponentVariableOptimumHead0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableOptimumPumpPowerInput0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableOptimumRateOfFlow0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariablePistonVelocity0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariablePossibleFluids0:String []0:DataItemTypeO, RO
0:HasComponentVariablePre_ChargePressure0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariablePumpClassPumpClassEnum0:DataItemTypeO, RO
0:HasComponentObjectPumpCurve0:FileTypeO
0:HasComponentObjectPumpEfficiencyCurve0:FileTypeO
0:HasComponentObjectPumpH_Q_Curve0:FileTypeO
0:HasComponentObjectPumpNpshCurve0:FileTypeO
0:HasComponentObjectPumpPowerInputCurve0:FileTypeO
0:HasComponentVariableShut_OffHead0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableShut_OffPumpPowerInput0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableSlipFlow0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableSoundEnergy0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableSoundEnergyLevel0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableSoundPower0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableSoundPowerLevel0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableSoundPressure0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableSoundPressureLevel0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableSpecificSpeed0:Double0:BaseAnalogTypeO, RO
0:HasComponentObjectStablePumpH_Q_Curve0:FileTypeO
0:HasComponentVariableStandardGasFlowrate0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableStartingPressure0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableSuction_SpecificSpeed0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableSweptVolume0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableTripSpeed0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableTypeNumber0:Double0:DataItemTypeO, RO
0:HasComponentVariableVolumeFlowRate0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableVolumeFlowRateOfBackingPump0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableWarmUpTimeForAVaporJetPumpOrADiffusionPump0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableWaterVaporTolerableLoad0:Double0:BaseAnalogTypeO, RO
0:HasComponentVariableWetCriticalSpeed0:Double0:BaseAnalogTypeO, RO

The optional Variable AdditionalFieldbuses is a one dimensional array with a limit of 128 entries.

The optional Variable PossibleFluids is a one dimensional array without a limit for possible entries.

The InstanceDeclarations of the DesignType have additional Attributes defined in Table 48. The Variables and the associated Descriptions are based on the standards DIN EN ISO 17769-1, DIN EN ISO 17769-2, DIN ISO 21360-1, ISO 3529-2, DIN 28400-2, DIN EN ISO 80000-8, ISO/TR 25417 and DIN EN 13306.

Table 48 – DesignType Attribute values for child Nodes
BrowsePath Value Attribute Description Attribute
AdditionalFieldbusesAdditional fieldbuses supported by the product.
BalancingRateOfFlowRate of flow which is extracted to activate a balance device

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067091

DisplayName: m³/s

Description: cubic metre per second

BasePressurePressure obtained in the test dome after conditioning the vacuum pump and the test dome

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

ClearanceVolumeVolume remaining unswept at the end of the discharge stroke.

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067857

DisplayName: m³

Description: cubic metre

ClockwiseRotationDirection of rotation in which the shaft is seen to be turning in a clockwise direction when viewing the drive end of the shaft. A "True" status means that the rotation of pump is clockwise and a "False" status means that the rotation of pump is anticlockwise.
ControllableIndicates whether the product is a controllable pump or a self-controlling pump. A "True" status means that the pump is controllable and a "False" status means that the pump is not controllable.
Cool_DownTimeForAVaporJetPumpOrADiffusionPumpThe cool-down time is the time required to cool the propellant from the working temperature to a temperature at which the propellant can be exposed to atmospheric air without risk after the heating has been switched off.

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5457219

DisplayName: s

Description: second [unit of time]

Counter_ClockwiseRotationDirection of rotation in which the shaft is seen to be turning in an anticlockwise direction, when viewing the drive end of the shaft. A "True" status means that the rotation of pump is anticlockwise and a "False" status means that the rotation of pump is clockwise.
CriticalSpeedSpeed of rotation at which the frequency of vibration (or its multiples) corresponds to the rotor resonant (lateral or torsional)

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4405559

DisplayName: s⁻¹

Description: reciprocal second

DeclarationOfConformityPublicly accessible attestation of conformity, commonly available on websites.
DeclarationOfConformityAvailableWhether or not a declaration of conformity exists. A "True" status means that the declaration exists and a "False" status means that there is no declaration available.
DesignAxialLoadResidual axial thrust on the pump rotor on which the thrust-bearing selection is based.

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5129559

DisplayName: N

Description: newton

DesignRadialLoadRadial load of the pump rotor for which the bearing system is selected.

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5129559

DisplayName: N

Description: newton

DirectivesOfEUDeclarationOfConformitySet of directives on the basis of which conformity was determined.
DryCriticalSpeedRotor resonant frequency calculated assuming that the rotor is supported only at its bearings and that the bearings are of infinite stiffness

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4405559

DisplayName: s⁻¹

Description: reciprocal second

ExplosionProtectionDevice category for explosion protection according to 2014/34/EU (ATEX).
GeometricalFlowProduct of geometrical displacement volume and speed of rotation or stroke frequency

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067091

DisplayName: m³/s

Description: cubic metre per second

GeometricDisplacementVolumeDisplacement volume for one stroke or one cycle.

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067857

DisplayName: m³

Description: cubic metre

HeadAtPeakPointHighest total head developed by a pump when this does not occur at a zero rate of flow

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

InstallationNpshCurveRelationship between the net positive suction head available and the rate of flow at given operating conditions for a given liquid
LeakageRateOfFlowRate of flow leaking from shaft seals

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067091

DisplayName: m³/s

Description: cubic metre per second

MaximumAllowableAmbientTemperatureHighest allowable ambient temperature for which the equipment (or any part to which the term refers) is suitable

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4932940

DisplayName: K

Description: kelvin

MaximumAllowableCasingWorkingPressureGreatest outlet pressure at the specified operating temperature at which the pump casing can be used

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

MaximumAllowableContinuousSpeedHighest rotational speed for continuous operation recommended by the manufacturer

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4405559

DisplayName: s⁻¹

Description: reciprocal second

MaximumAllowableHeadMaximum permissible head at which the pump can be continuously operated without suffering damage

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

MaximumAllowableRelativeHumidityHighest allowable relative humidity for which the equipment (or any part to which the term refers) is suitable

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 20529

DisplayName: %

Description: percent

MaximumAllowableTemperatureHighest allowable continuous fluid temperature for which the equipment (or any part to which the term refers) is suitable when handling the specified operating fluid at the specified operating pressure

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4932940

DisplayName: K

Description: kelvin

MaximumAllowableThroughputMaximum pV flow the pump can withstand without damage

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4665393

DisplayName: Pa·m³/s

Description: pascal cubic metre per second

MaximumAllowableWorkingPressurePressure for a component on the basis of materials used and on the basis of calculation rules at the specified operating temperature

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

MaximumAxialLoadGreatest value of the residual axial thrust on the pump rotor resulting from operating the pump at any condition within its allowable operating range.

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5129559

DisplayName: N

Description: newton

MaximumPumpPowerInputHighest value of the pump power input at any rate of flow at any allowable operating condition

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5723220

DisplayName: W

Description: watt

MaximumRadialLoadGreatest radial load of the pump rotor resulting from operating the pump at any condition within its allowable operating range.

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5129559

DisplayName: N

Description: newton

MaximumStaticSealingPressureHighest pressure, excluding hydrostatic testing, to which the seal can be subjected while the pump is shut down

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

MeanTimebetweenFailuresAverage of the times between failures.

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4740434

DisplayName: h

Description: hour

MinimumAllowableAmbientTemperatureLowest allowable ambient temperature for which the equipment (or any part to which the term refers) is suitable

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4932940

DisplayName: K

Description: kelvin

MinimumAllowableContinuousSpeedLowest speed for continuous operation recommended by the manufacturer

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4405559

DisplayName: s⁻¹

Description: reciprocal second

MinimumAllowableHeadMinimum permissible head at which the pump can be operated without suffering damage

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

MinimumAllowableRelativeHumidityLowest allowable relative humidity for which the equipment (or any part to which the term refers) is suitable

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 20529

DisplayName: %

Description: percent

MinimumAllowableTemperatureLowest allowable continuous temperature for which the equipment (or any part to which the term refers) is suitable when handling the specified operating fluid at the specified operating pressure

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4932940

DisplayName: K

Description: kelvin

MinimumAllowableThermalFlowLowest flow at which the pump can operate without its operation being impaired by the temperature rise of the pumped liquid

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067091

DisplayName: m³/s

Description: cubic metre per second

MinimumContinuousStableFlowLowest flow at which the pump can be operated without it adversely affecting its performance in terms of life expectancy, noise and vibrations

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067091

DisplayName: m³/s

Description: cubic metre per second

MinimumContinuousThermalFlowLowest flow at which the pump can operate without its operation being impaired by the temperature rise of the pumped liquid

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067091

DisplayName: m³/s

Description: cubic metre per second

NetPositiveSuctionHeadRequiredMinimum NPSH at the pump inlet connection required to give the rated or operating performance at the specified conditions

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

NetPositiveSuctionHeadRequiredForADropOf3PercentNPSH required for a drop of 3 % in the total head of the first stage of the pump as a standard basis for use in performance curves

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

OfferedControlModesControl modes supported by the manufacturer for the product.
OfferedFieldbusesFieldbuses supported by the manufacturer for the product.
OptimumHeadTotal head developed by the pump at a rate of flow corresponding to the best efficiency

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

OptimumPumpPowerInputPump power input at the rate of flow corresponding to the best efficiency

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5723220

DisplayName: W

Description: watt

OptimumRateOfFlowRate of flow at the point of best efficiency

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067091

DisplayName: m³/s

Description: cubic metre per second

PistonVelocityAverage speed given by the stroke length multiplied with the number of complete pumping cycles of the piston, plunger or piston attached to the diaphragm per minute (stroke per minute or pump crank speed)

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067859

DisplayName: m/s

Description: metre per second

PossibleFluidsFluids that can be pumped by the pump.
Pre_ChargePressurePressure to which the pulsation dampener is charged with dry gas prior to start of operation

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

PumpClassPump type according to functional principle and pumped fluid
PumpCurveRepresentation of the pump head plotted against the flow rate
PumpEfficiencyCurveRelationship between the pump efficiency and the rate of flow at given operating conditions of speed and liquid
PumpH_Q_CurveRelationship between the total head of the pump and the rate of flow at given operating conditions /rated conditions of speed and liquid
PumpNpshCurveRelationship between the net positive suction head required and the rate of flow at given operating conditions of speed and liquid
PumpPowerInputCurveRelationship between the pump power input and the rate of flow given operating conditions of speed and liquid
Shut_OffHeadTotal head developed by the pump in a zero rate of flow

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067858

DisplayName: m

Description: metre

Shut_OffPumpPowerInputPump power input at zero rate of flow

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5723220

DisplayName: W

Description: watt

SlipFlowFlow lost internally through clearances

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067091

DisplayName: m³/s

Description: cubic metre per second

SoundEnergyIntegral of the sound power, P, over a stated time interval of duration T (starting at t1 and ending at t2).

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4869973

DisplayName: J

Description: joule

SoundEnergyLevelTen times the logarithm to the base 10 of the ratio of the sound energy, J, to a reference value, J0, expressed in decibels.

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 12878

DisplayName: dB

Description: decibel

SoundPowerThrough a surface, product of the sound pressure, p, and the component of the particle velocity, un, at a point on the surface in the direction normal to the surface, integrated over that surface.

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5723220

DisplayName: W

Description: watt

SoundPowerLevelTen times the logarithm to the base 10 of the ratio of the sound power of a source, P, to a reference value, P0, expressed in decibels.

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 12878

DisplayName: dB

Description: decibel

SoundPressureDifference between instantaneous pressure and static pressure.

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

SoundPressureLevelTen times the logarithm to the base 10 of the ratio of the square of the sound pressure, p, to the square of a reference value, p0, expressed in decibels.

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 12878

DisplayName: dB

Description: decibel

SpecificSpeedSpeed that characterizes a pump in terms of its speed, flow rate per impeller eye, i.e. total flow for single-flow impeller, half flow for double-flow impeller, at the best efficiency point and head per stage at maximum impeller diameter

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4405559

DisplayName: s⁻¹

Description: reciprocal second

StablePumpH_Q_CurvePump H(Q) curve where the maximum head and shut-off head are coincidental, and the total head declines continuously as the rate of flow increases
StandardGasFlowrateVolume flow rate at standard reference conditions, i.e. 0 °C and 101 325 Pa

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067091

DisplayName: m³/s

Description: cubic metre per second

StartingPressureThe starting pressure is the pressure at which a vacuum pump can be switched on and a pumping effect is achieved without damage occurring.

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5259596

DisplayName: Pa

Description: pascal

Suction_SpecificSpeedSpeed that characterizes a pump's cavitation performance in terms of its speed, optimum rate of flow per impeller eye at best efficiency point and NPSH3 at best efficiency point for the first stage at maximum impeller diameter

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4405559

DisplayName: s⁻¹

Description: reciprocal second

SweptVolumeVolume traversed by a single stroke of piston, plunger or diaphragm.

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067857

DisplayName: m³

Description: cubic metre

TripSpeedSpeed at which the independent emergency overspeed devices operate to shut down a prime mover

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4405559

DisplayName: s⁻¹

Description: reciprocal second

TypeNumberPure number calculated at the point of best efficiency
VolumeFlowRateVolume flow rate of the gas removed by the pump from the gas phase within the evacuated chamber.

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067091

DisplayName: m³/s

Description: cubic metre per second

VolumeFlowRateOfBackingPumpMaximum volume flow rate for which the conditions are defined in the instruction manual or in a specific standard for the particular vacuum pump

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5067091

DisplayName: m³/s

Description: cubic metre per second

WarmUpTimeForAVaporJetPumpOrADiffusionPumpThe warm-up time is the time required to heat the blowing agent in the boiling vessel to its working temperature. The initial temperature can either be equal to the ambient temperature or equal to the temperature at which the blowing agent of the vacuum pump can be exposed to atmospheric air without risk.

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 5457219

DisplayName: s

Description: second [unit of time]

WaterVaporTolerableLoadThe mass flow rate for water vapor, in a gas ballast pump, in continuous operation and under normal ambient conditions, if the pumped gas is pure water vapor.

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4933459

DisplayName: kg/s

Description: kilogram per second

WetCriticalSpeedRotor resonant frequency calculated considering the additional support and damping produced by the action of the pumped fluid within rotor

NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact

UnitId: 4405559

DisplayName: s⁻¹

Description: reciprocal second