In Table 30, the Methods of the ObjectType, referenced via the MethodSet Object are defined.
Table 30 – MethodSet of IOLinkMasterType
References |
Node Class |
BrowseName |
Modelling Rule |
The following Methods are also referenced by the Management Object |
|||
HasComponent |
Method |
Restart |
Mandatory |
|
|
|
|
The following Methods are also referenced by the Statistics Object |
|||
HasComponent |
Method |
ResetStatisticsOnAllPorts |
Optional |
The Method Restart restarts the IO-Link Master.
Signature
Restart (
[in]Duration Delay,
[out]Int32 Status
);
Argument |
Description |
Delay |
Time before the restart becomes effective. |
Status |
Returns the status of the operation. 0: OK, operation successful -1: Operation already running -2: Operation cannot be executed -3: Operation cannot be executed because master reconfiguration is disabled. |
The optional Method ResetStatisticsOnAllPorts resets all statistic data, including statistic data of the ports of the IO-Link Master. Statistic data of a port are all Parameters referenced by the Statistics Object of the IOLinkPortType Object starting with “NumberOf” and potentially vendor-specific extensions. Statistic data directly on the IO-Link Master includes the Variable NumberOfIOLinkMasterStarts and potential vendor-specific extensions. As soon as statistic data is provided by the server, the optional Method shall be provided.
Signature
ResetStatisticsOnAllPorts (
[out]Int32 Status
);
Argument |
Description |
Delay |
Time before the reset becomes effective. |
Status |
Returns the status of the operation. 0: OK, operation successful -1: Operation already running -2: Operation cannot be executed. |