8.5 IsDrivenBy (Drives) Reference Type
The OPC UA ReferenceType IsDrivenBy is used to describe dependencies between objects which have a driving or powering character. The BrowseName IsDrivenBy and the InverseName Drives describe semantically the hierarchical dependency.
Example for usage in this companion specification: an electrical motor IsDrivenBy and servo amplifier (drive) and an internal drive of a motion device or a drive as a component of a controller Drives a motor.
The SourceNode of this type shall be an ObjectType or Object and the TargetNode shall be an Object.
| Attributes | Value | ||||
| BrowseName | IsDrivenBy | ||||
| InverseName | Drives | ||||
| Symmetric | False | ||||
| IsAbstract | False | ||||
| Subtype of the HierarchicalReferences defined in OPC Unified Architecture Part 5 | |||||
| References | NodeClass | BrowseName | DataType | TypeDefinition | ModellingRule |
|---|