Search
200 result(s) for .
-
OPC-10000-2 – OPC Unified Architecture - Part 2: Security Model4.13 OPC UA security related Services The OPC UA Security
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model5.2.4 BrowseName5.2.4 BrowseName Nodes have a BrowseName Attribute that is used
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model5.3.2 Attributes5.3.2 Attributes The ReferenceType NodeClass inherits the base Attributes from
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model7.13 HasTypeDefinition ReferenceType The HasTypeDefinition ReferenceType is a concrete ReferenceType
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model8.51 StructureField8.51 StructureField This Structured DataType is used to provide the
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model8.55 PermissionType8.55 PermissionType This is a subtype of the UInt32 DataType
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.5.1 Overview5.5.1 Overview This Service Set defines Services used to discover
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.11.3.2 Parameters5.11.3.2 Parameters Table 50 defines the parameters for the Service
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services6.1.4 Creating a SecureChannel6.1.4 Creating a SecureChannel All OPC UA Applications shall establish
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services7.2 ApplicationDescription The components of this parameter are defined in
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services7.22.3 EventFilter7.22.3 EventFilter The EventFilter provides for the filtering and content
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services7.32 RequestHeader7.32 RequestHeader The components of this parameter are defined in
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services7.40.2.4 RsaEncryptedSecret DataType7.40.2.4 RsaEncryptedSecret DataType The RsaEncryptedSecret uses RSA based Asymmetric Cryptography
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services7.40.2.5 EccEncryptedSecret DataType7.40.2.5 EccEncryptedSecret DataType The EccEncryptedSecret uses ECC based Asymmetric Cryptography
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services7.41 UserTokenPolicy7.41 UserTokenPolicy The components of this parameter are defined in
-
OPC-10000-4 – OPC Unified Architecture - Part 4: ServicesB.3.1 OverviewB.3.1 Overview These query examples illustrate complex filters . The following
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model6.3.2 ServerCapabilitiesType6.3.2 ServerCapabilitiesType This ObjectType defines the capabilities supported by the
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model6.3.15 NonTransparentBackupRedundancyType This ObjectType is a subtype of NonTransparentRedundancyType intended
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model12.39 UriString12.39 UriString This simple DataType is a subtype of String
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information ModelC.2.6 FieldTypeC.2.6 FieldType A FieldType describes a binary encoded value that
-
OPC-10000-6 – OPC Unified Architecture - Part 6: Mappings3.1.1 CertificateThumbprint3.1.1 CertificateThumbprint short identifier used to uniquely identify an X.509
-
OPC-10000-6 – OPC Unified Architecture - Part 6: Mappings5.2.2.15 ExtensionObject5.2.2.15 ExtensionObject An ExtensionObject is encoded as sequence of bytes
-
OPC-10000-6 – OPC Unified Architecture - Part 6: Mappings6.1 Security Handshake and Security Policies All SecurityProtocols shall implement
-
OPC-10000-6 – OPC Unified Architecture - Part 6: Mappings7.1.3 Establishing a connection Connections may be initiated by the
-
OPC-10000-6 – OPC Unified Architecture - Part 6: Mappings7.1.4 Closing a connection7.1.4 Closing a connection The Client closes the connection by
-
OPC-10000-6 – OPC Unified Architecture - Part 6: MappingsF.2 UANodeSetF.2 UANodeSet The UANodeSet is the root of the document
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data Access5.3.1 DataItemType5.3.1 DataItemType This VariableType defines the general characteristics of a
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data Access5.3.4.1 General5.3.4.1 General This abstract VariableType defines the general characteristics of
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data AccessA.3.1.3 ItemA.3.1.3 Item DA items (leafs) are represented in the COM
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data AccessA.4.2.3 Variable NodesA.4.2.3 Variable Nodes A node of Variable Node class in
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.5.2 ConditionType5.5.2 ConditionType The ConditionType defines all general characteristics of a
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.17.2 Unshelve Method5.8.17.2 Unshelve Method The Unshelve Method sets the instance of
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.17.4 TimedShelve Method5.8.17.4 TimedShelve Method The TimedShelve Method sets the instance of
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.17.6 OneShotShelve Method5.8.17.6 OneShotShelve Method The OneShotShelve Method sets the instance of
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.18 LimitAlarmType5.8.18 LimitAlarmType Alarms can be modelled with multiple exclusive sub
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions8.3 AlarmMask8.3 AlarmMask This OptionSet defines flags indicating the summary of
-
OPC-10000-10 – OPC Unified Architecture - Part 10: Programs4.2.7 Program Control Methods4.2.7 Program Control Methods Clients manage a Program by calling
-
OPC-10000-10 – OPC Unified Architecture - Part 10: Programs4.2.10.1 Overview4.2.10.1 Overview Programs can have different lifetimes. Some Programs may
-
OPC-10000-10 – OPC Unified Architecture - Part 10: Programs4.2.10.2 Program instances4.2.10.2 Program instances Programs can be multiple instanced or single
-
OPC-10000-10 – OPC Unified Architecture - Part 10: Programs5.1 General5.1 General The Program model extends the FiniteStateMachineType and basic
-
OPC-10000-10 – OPC Unified Architecture - Part 10: Programs5.2.3.3 ProgramStateMachineType transitions ProgramStateMachineType Transitions are instances of the TransitionType
-
OPC-10000-10 – OPC Unified Architecture - Part 10: Programs5.2.4.1 Overview5.2.4.1 Overview The ProgramStateMachineType includes references to the Causes of
-
OPC-10000-10 – OPC Unified Architecture - Part 10: Programs5.2.5.1 Overview5.2.5.1 Overview The ProgramStateMachineType includes component references to the Effects
-
OPC-10000-10 – OPC Unified Architecture - Part 10: ProgramsA.2.3 DomainDownload transitions The valid state transitions specified for the
-
OPC-10000-10 – OPC Unified Architecture - Part 10: ProgramsA.2.4.1 GeneralA.2.4.1 General Four standard Program Methods are specified for running
-
OPC-10000-10 – OPC Unified Architecture - Part 10: ProgramsA.2.6.2 DomainDownloadTypeA.2.6.2 DomainDownloadType The DomainDownloadType is a subtype derived from the
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access5.1.1 General5.1.1 General The Historical Access model defines additional Properties that
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access6.9.3.2 Specified Uniqueness of StructuredHistoryData StructuredHistoryData provides metadata describing an
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services4.3.2 Simple Discovery with a DiscoveryUrl Every Server has one
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services6.5.5 ApplicationRecordDataType This type defines a DataType which represents a
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services6.5.10 QueryApplications6.5.10 QueryApplications QueryApplications is used to find Clients that support
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services6.5.11 QueryServers (deprecated)6.5.11 QueryServers (deprecated) QueryServers is used to find Server applications
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services7.3 Pull Management7.3 Pull Management PullManagement is performed by using the CertificateManager
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services7.7.2 Update Certificates Workflow This workflow is started if the
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services7.8.2.5 CloseAndUpdate7.8.2.5 CloseAndUpdate The CloseAndUpdate Method closes the TrustList and applies
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services7.8.3.4 CertificateGroupDataType7.8.3.4 CertificateGroupDataType This type is used to serialize a single
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services7.9.2 CertificateDirectoryType7.9.2 CertificateDirectoryType This ObjectType is the TypeDefinition for the root
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services7.9.3 StartSigningRequest7.9.3 StartSigningRequest The StartSigningRequest Method is used to initiate a
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services7.10.21 ApplicationIdentityDataType7.10.21 ApplicationIdentityDataType This type is used to serialize the ApplicationIdentity
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services8.5.5 StartRequest8.5.5 StartRequest StartRequest is used to request a new KeyCredential
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services8.5.7 Revoke8.5.7 Revoke The Revoke Method is used to revoke a
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services8.6.3 CreateCredential8.6.3 CreateCredential CreateCredential is used to add a new KeyCredentialConfiguration
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services8.6.6 GetEncryptingKey8.6.6 GetEncryptingKey The GetEncryptingKey Method is used to request a
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services8.6.7 UpdateCredential8.6.7 UpdateCredential The UpdateCredential Method is used to update a
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services8.6.8 DeleteCredential8.6.8 DeleteCredential The DeleteCredential Method is used to delete a
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services9.6.5 RequestAccessToken (Deprecated) It is deprecated because it can only
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services9.6.6 StartRequestToken9.6.6 StartRequestToken The StartRequestToken Method is used to initiate a
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services9.6.7 FinishRequestToken9.6.7 FinishRequestToken The FinishRequestToken Method is used to complete a
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services9.6.8 RefreshToken9.6.8 RefreshToken The RefreshToken Method is used to request an
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services9.7.5 AuthorizationServiceConfigurationDataType This type is used to serialize the AuthorizationService
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global ServicesA.1 Firewalls and Discovery Many systems will have multiple networks
-
OPC-10000-13 – OPC Unified Architecture - Part 13: Aggregates5.4.3.1 General5.4.3.1 General When accessing aggregated data using the HistoryRead or
-
OPC-10000-13 – OPC Unified Architecture - Part 13: Aggregates5.4.3.10 Minimum5.4.3.10 Minimum The Minimum Aggregate defined in Table 58 retrieves
-
OPC-10000-13 – OPC Unified Architecture - Part 13: Aggregates5.4.3.11 Maximum5.4.3.11 Maximum The Maximum Aggregate defined in Table 59 retrieves
-
OPC-10000-13 – OPC Unified Architecture - Part 13: Aggregates5.4.3.27 Delta5.4.3.27 Delta The Delta Aggregate defined in Table 75 retrieves
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub5.4.4 Configuration Tool5.4.4 Configuration Tool An OPC UA Application can be pre
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.9.4 DataSetMetaData6.2.9.4 DataSetMetaData The parameter DataSetMetaData provides the information necessary to
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.4.4.3.1 General7.2.4.4.3.1 General The security algorithms used and the length of
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.5.4.1 Message content7.2.5.4.1 Message content A DataSetMessage is produced by a DataSetWriter
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.5.5.2 DataSetMetaData7.2.5.5.2 DataSetMetaData DataSetMetaData describe the content of DataSetMessages published by
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.5.5.3 ApplicationDescription7.2.5.5.3 ApplicationDescription A NetworkMessage with MessageType ApplicationDescription is a JSON
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.5.5.4 ServerEndpoints7.2.5.5.4 ServerEndpoints A NetworkMessage with MessageType ServerEndpoints is a JSON
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.5.5.5 Status7.2.5.5.5 Status A NetworkMessage with MessageType Status is a JSON
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.5.5.6 PubSubConnection7.2.5.5.6 PubSubConnection A NetworkMessage with MessageType PubSubConnection is a JSON
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.5.5.7 ActionMetaData7.2.5.5.7 ActionMetaData A NetworkMessage with MessageType ActionMetaData is a JSON
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.5.5.8 ActionResponder7.2.5.5.8 ActionResponder A NetworkMessage with MessageType ActionResponder is a JSON
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.5.6.1 Action NetworkMessage7.2.5.6.1 Action NetworkMessage Each JSON Action NetworkMessage can contain one
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.5.6.2 ActionRequest7.2.5.6.2 ActionRequest A NetworkMessage with MessageType "ua-action-request
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.5.6.3 ActionResponse7.2.5.6.3 ActionResponse A NetworkMessage with MessageType "ua-action-response
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.3.4.1 General7.3.4.1 General MQTT is an open standard application layer protocol
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.3.4.4 Connection properties7.3.4.4 Connection properties The MQTT transport mapping for version 3.1.1
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.3.4.8 Message header7.3.4.8 Message header The default setting for the MQTT RETAIN
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub8.3.2 GetSecurityKeys Method8.3.2 GetSecurityKeys Method This Method is used to retrieve the
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub8.4.3 ForceKeyRotation Method8.4.3 ForceKeyRotation Method This Method forces a key update prior
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.3.3 SetSecurityKeys9.1.3.3 SetSecurityKeys This Method is used to push the security
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.3.7.2 PubSubConfigurationRefMask9.1.3.7.2 PubSubConfigurationRefMask This OptionSet defines flags indicating the PubSubConfigurationRefDataType options
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.4.5.4 AddPublishedDataItemsTemplate Method9.1.4.5.4 AddPublishedDataItemsTemplate Method This Method is used to create a
-
OPC-10000-16 – OPC Unified Architecture - Part 16: State Machines4.4.5 TransitionVariableType4.4.5 TransitionVariableType The TransitionVariableType is the base VariableType for Variables
-
OPC-10000-17 – OPC Unified Architecture - Part 17: Alias NamesD.1.3 PubSub AliasName Notification Configuration The setting for a PubSub
-
OPC-10000-18 – OPC Unified Architecture - Part 18: Role-Based Security4.2.2 AddRole Method4.2.2 AddRole Method This Method is used to add a
-
OPC-10000-21 – OPC Unified Architecture - Part 21: Device Onboarding3.1.11 Distributor3.1.11 Distributor an organization that re-sells Devices and/or Composites
-
OPC-10000-21 – OPC Unified Architecture - Part 21: Device Onboarding5.3 Composite Identity A Composite is a piece of equipment
-
OPC-10000-21 – OPC Unified Architecture - Part 21: Device Onboarding9.2.8 RegisterManagedApplication The RegisterManagedApplication Method allows a DCA using pull
-
OPC-10000-23 – OPC Unified Architecture - Part 23: Common ReferenceTypes5.2 Reference Refinement Sometimes, a high-level Reference might be
-
OPC-10000-26 – Part 26: LogObject - Part 26: LogObject Model5.3 GetRecords Method This Method allows a Client to retrieve
-
OPC-10000-26 – Part 26: LogObject - Part 26: LogObject Model5.6.2 SpanContext Structure5.6.2 SpanContext Structure The SpanContextDataType Structure is defined in Table
-
OPC-10000-26 – Part 26: LogObject - Part 26: LogObject Model7.2 ServerLog7.2 ServerLog The following instance can exist in Servers if
-
OPC-10000-26 – Part 26: LogObject - Part 26: LogObject ModelA.2 Event History Illustration A Server that supports EventHistory , might
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.2.4.2 EstablishConnections signature6.2.4.2 EstablishConnections signature The signature of this Method is specified
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.2.4.3.9.2 PubSub6.2.4.3.9.2 PubSub The communication configuration applied in the case of
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.2.5.2 CloseConnections behaviour6.2.5.2 CloseConnections behaviour The Method implementation shall disable all communication
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.3.3 VerifyAsset method6.3.3 VerifyAsset method The VerifyAsset Method allows a Client to
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.4.3 Verify method6.4.3 Verify method The Verify Method allows a Client to
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.4.6.4 ClearStoredVariables Method6.4.6.4 ClearStoredVariables Method The optional ClearStoredVariables Method allows a Client
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.7.2 ConnectionManagerType definition The ConnectionManagerType is formally defined in Table
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model8.9 EstablishConnectionErrorEventType This EventType is generated by a ConnectionManager when
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model8.10 CloseConnectionErrrorEventType This EventType is generated by a ConnectionManager when
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model10.34 OperationalHealthOptionSet This OptionSet defines flags indicating the health of
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelE.4.1 OverviewE.4.1 Overview This clause describes the configuration settings for the
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelE.5 Interaction with an SKS The usage of SecurityGroups is
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelG.1 Diagnostics Client This Annex describes behaviour that a diagnostics
-
OPC-10000-82 – OPC Unified Architecture - Part 82: UAFX Networking6.5.4 Default PriorityMappingTable configuration A UAFX Station shall provide a
-
OPC-10000-83 – OPC Unified Architecture - Part 83: UAFX OfflineEngineeringA.4 NodeClass mapping The OPC UA metamodel uses the concept
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles5.2.3 UAFX AutomationComponent5.2.3 UAFX AutomationComponent Table 4 describes AutomationComponent related UAFX Information
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles5.2.6 UAFX ConnectionManager5.2.6 UAFX ConnectionManager Table 7 describes ConnectionManager -related UAFX Information
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles5.4.2 UAFX OfflineEngineering Descriptor Table 10 describes UAFX OfflineEngineering Descriptor
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles6.6.2.20 UAFX ClampBlock AssetConnector Facet6.6.2.20 UAFX ClampBlock AssetConnector Facet Table 34 describes the details
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles6.6.4.5 UAFX SKS Push 2023 Facet6.6.4.5 UAFX SKS Push 2023 Facet Table 44 describes the
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devices8.4.1.7 Parameters8.4.1.7 Parameters This optional Parameters Object is of type TemporaryFileTransferType
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devices9.3 Block Devices9.3 Block Devices A Block -oriented Device can be composed
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basics8.2.3 AssetsByAssetId8.2.3 AssetsByAssetId The AssetsByAssetId Object is formally defined in Table
-
OPC-10000-200 – OPC Unified Architecture - Part 200: Industrial Automation6.2.2 IAggregateStatisticsType6.2.2 IAggregateStatisticsType The IAggregateStatisticsType is a subtype of the IStatisticsType
-
OPC-10000-200 – OPC Unified Architecture - Part 200: Industrial Automation7.4.1 CalibrationTargetType ObjectType The CalibrationTargetType provides information about a calibration
-
OPC-10030 – OPC Unified Architecture - Common Object Model: ISA-959.2.8 TestedBy9.2.8 TestedBy The TestedBy ReferenceType is an abstract ReferenceType that
-
OPC-10030 – OPC Unified Architecture - Common Object Model: ISA-959.2.9 ImplementedBy9.2.9 ImplementedBy The ImplementedBy is a concrete ReferenceType that can
-
OPC-10030 – OPC Unified Architecture - Common Object Model: ISA-959.2.10 HasTestResult9.2.10 HasTestResult The HasTestResult is a concrete ReferenceType that can
-
OPC-10030 – OPC Unified Architecture - Common Object Model: ISA-959.2.11 ResultsForSpecification9.2.11 ResultsForSpecification The ResultsForSpecification is a concrete ReferenceType that can
-
OPC-10030 – OPC Unified Architecture - Common Object Model: ISA-959.3.2 TestedByQualificationTest The TestedBy ReferenceType is a concrete ReferenceType that
-
OPC-10030 – OPC Unified Architecture - Common Object Model: ISA-959.4.3 TestedByEquipmentTest9.4.3 TestedByEquipmentTest The TestedByEquipmentTest ReferenceType is a concrete ReferenceType that
-
OPC-10030 – OPC Unified Architecture - Common Object Model: ISA-959.5.3 TestedByPhysicalAssetTest The TestedBy PhysicalAsset Test ReferenceType is a concrete
-
OPC-10030 – OPC Unified Architecture - Common Object Model: ISA-959.6.3 TestedByMaterialTest9.6.3 TestedByMaterialTest The TestedBy ReferenceType is a concrete ReferenceType that
-
OPC-10030 – OPC Unified Architecture - Common Object Model: ISA-959.6.4 AssembledFrom9.6.4 AssembledFrom The AssembledFrom ReferenceType is an abstract ReferenceType . It
-
OPC-10030 – OPC Unified Architecture - Common Object Model: ISA-959.6.5 AssembledFromDefinition9.6.5 AssembledFromDefinition The AssembledFromDefinition ReferenceType is a Concrete ReferenceType hat
-
OPC-10030 – OPC Unified Architecture - Common Object Model: ISA-959.6.6 AssembledFromClass9.6.6 AssembledFromClass The AssembledFromClass ReferenceType is a Concrete ReferenceType hat
-
OPC-10030 – OPC Unified Architecture - Common Object Model: ISA-959.6.7 AssembledFromLot9.6.7 AssembledFromLot The AssembledFromLot ReferenceType is a Concrete ReferenceType hat
-
OPC-10030 – OPC Unified Architecture - Common Object Model: ISA-959.6.8 AssembledFromSublot9.6.8 AssembledFromSublot The AssembledFromSublot ReferenceType is a Concrete ReferenceType hat
-
OPC-10030 – OPC Unified Architecture - Common Object Model: ISA-95Annex E xtensionsAnnex E xtensions ISA95HierarchyScopeType The ISA95HierarchyScopeType is a concrete VariableType
-
OPC-30000 – OPC UA for Programmable Logic Controllers based on IEC61131-35 Use cases The following use cases illustrate the usage
-
OPC-30000 – OPC UA for Programmable Logic Controllers based on IEC61131-37.6 CtrlTaskType ObjectType Definition This ObjectType defines the representation of
-
OPC-30001 – OPC UA Client Function Blocks for IEC 61131-37.6 UA_TranslatePathList FB-Name UA_TranslatePathList This Function Block
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices6.2.1 General6.2.1 General This OPC UA ObjectType represents an OCR reader
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices6.3.1 General6.3.1 General This OPC UA ObjectType represents an optical reader
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices6.4.1 General6.4.1 General This OPC UA ObjectType represents an optical verifier
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices6.5.1 General6.5.1 General This OPC UA ObjectType represents an RFID reader
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices7.8 AutoIdDiagnosticsEventType The AutoIdDiagnosticsEventType is formally defined in Table 23
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices7.9 AutoIdLogEntryEventType The AutoIdLogEntryEventType is formally defined in Table 24
-
OPC-30020 – MDIS OPC UA Companion Specification6.6.4 Choke Move Method6.6.4 Choke Move Method Move Method is used to adjust
-
OPC-30020 – MDIS OPC UA Companion Specification6.6.5 Choke Step Method6.6.5 Choke Step Method Choke Step Method is used to
-
OPC-30020 – MDIS OPC UA Companion Specification6.6.6 Choke Abort Method6.6.6 Choke Abort Method Choke Abort Method is used to
-
OPC-30020 – MDIS OPC UA Companion Specification6.9.5 SetFlowRate Method6.9.5 SetFlowRate Method SetFlowRate Method is used to set a
-
OPC-30020 – MDIS OPC UA Companion Specification6.9.6 SetPosition Method6.9.6 SetPosition Method SetPosition Method is used to set a
-
OPC-30020 – MDIS OPC UA Companion Specification6.9.7 SetManual Method6.9.7 SetManual Method CIMV SetManual Method is used to open
-
OPC-30020 – MDIS OPC UA Companion Specification6.9.8 Abort Method6.9.8 Abort Method CIMV Abort Method is used to halt
-
OPC-30020 – MDIS OPC UA Companion Specification6.12.2 MDISAggregateObjectType DefinitionTable 83 defines the structure of an
-
OPC-30020 – MDIS OPC UA Companion Specification9.2 InterlockFor9.2 InterlockFor The InterlockFor ReferenceType is a concrete ReferenceType and
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model7.3.1 General7.3.1 General This OPC UA ObjectType represents a BACnet Device
-
OPC-30050 – OPC UA for PackML - Common Object Model: PackML6.3.6 PackMLBaseStateMachineType The PackMLBaseStateMachineType is the top level StateMachine for
-
OPC-30142 – OPC UA for PROFINET Remote IO7.1.3.1 SetSimulation Method7.1.3.1 SetSimulation Method This Method sets the Value of array
-
OPC-30142 – OPC UA for PROFINET Remote IO7.1.3.2 SetSimulationValue Method7.1.3.2 SetSimulationValue Method This Method sets the Value of array
-
OPC-30142 – OPC UA for PROFINET Remote IO7.1.5.1 SetSimulation Method7.1.5.1 SetSimulation Method This Method sets the Value of array
-
OPC-30142 – OPC UA for PROFINET Remote IO7.1.5.2 SetSimulationValue Method7.1.5.2 SetSimulationValue Method This Method sets the Value of array
-
OPC-30142 – OPC UA for PROFINET Remote IO12.2.2.5 PNRIO Grouped Channels Server Profile From the PNRIO Conformance
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Model7.1.1 SetApplicationTag Method7.1.1 SetApplicationTag Method This Method sets the Value of the
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Model10.4 GsdGenIoCommunicationStatusEnumeration This enumeration describes the Submodule s IO status
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Model10.5 GsdGenIoConfigurationStatusEnumeration This enumeration describes the Submodule s configuration status
-
OPC-30145 – OPC UA for PROFINET Drives - Part 30145: UA CS for PROFINET Drives7.3 FrequencyDriveAxisType A FrequencyDriveAxisType is a DriveAxisType with a frequency
-
OPC-30145 – OPC UA for PROFINET Drives - Part 30145: UA CS for PROFINET Drives7.4 PositioningDriveAxisType A PositioningDriveAxisType is an DriveAxisType with a motion
-
OPC-30145 – OPC UA for PROFINET Drives - Part 30145: UA CS for PROFINET Drives7.7 TraversingTaskType The TraversingTaskType represents a traversing task. Table 28
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: Basics7.2.2 ResultType ObjectType Definition The ResultType provides the results of
-
OPC-40001-2 – OPC UA for Machinery - Part 2: Process Values9.1 ProcessValueSetpointVariableType VariableType Definition The ProcessValueSetpointVariableType is a subtype of
-
OPC-40010-1 – OPC UA for Robotics - Part 1: Vertical Integration7.10 OperationStateMachineType Definition The OperationStateMachineType provides an abstract state machine
-
OPC-40010-1 – OPC UA for Robotics - Part 1: Vertical Integration7.12.3 GetReady Method7.12.3 GetReady Method The signature of this Method is specified
-
OPC-40010-1 – OPC UA for Robotics - Part 1: Vertical Integration7.15 TaskControlOperationType ObjectType The TaskControlOperationType is an AddIn to extend
-
OPC-40010-1 – OPC UA for Robotics - Part 1: Vertical Integration7.20.1 Overview7.20.1 Overview The DriveType describes drives (multi-slot or single
-
OPC-40010-1 – OPC UA for Robotics - Part 1: Vertical Integration7.21.2 TaskControlType definition7.21.2 TaskControlType definition Table 100 - TaskControlType Definition Attribute Value BrowseName
-
OPC-40082-2 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 2: Hot runner devices9.10 EvenHeatUpMaxTemperatureDifference Even heat-up is a process for uniform
-
OPC-40082-2 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 2: Hot runner devices13.6 HeatUp13.6 HeatUp Setting for heat up procedure. HeatUp is an
-
OPC-40082-2 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 2: Hot runner devices16 HeatUpType16 HeatUpType HeatUpType is optional and an alternative to the
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management13.2.2 Server13.2.2 Server Table 158 defines the server based Conformance Units
-
OPC-40200 – OPC UA for Weighing Technology7.1.3 ObjectType Description7.1.3 ObjectType Description FeederLoad defines the current loaded weight on
-
OPC-40200 – OPC UA for Weighing Technology7.2.3 ObjectType Description7.2.3 ObjectType Description LabelLength defines the length of the labels
-
OPC-40200 – OPC UA for Weighing Technology7.3.3 ObjectType Description7.3.3 ObjectType Description The Identification - AddIn contains information about the
-
OPC-40200 – OPC UA for Weighing Technology7.4.3 ObjectType Description7.4.3 ObjectType Description AllowedEngineeringUnits contains an array of engineering units
-
OPC-40200 – OPC UA for Weighing Technology7.11.3 ObjectType Description7.11.3 ObjectType Description ProductionPreset, which is inherited from ScaleDeviceType shall
-
OPC-40200 – OPC UA for Weighing Technology7.14.3 ObjectType Description7.14.3 ObjectType Description ProductionPreset, which is inherited from ScaleDeviceType shall
-
OPC-40200 – OPC UA for Weighing Technology7.17.3 ObjectType Description7.17.3 ObjectType Description TU1Percent is the permitted percentage of items
-
OPC-40200 – OPC UA for Weighing Technology7.24.3 ObjectType Description7.24.3 ObjectType Description Totalizer defines the overall material quantity (weight
-
OPC-40200 – OPC UA for Weighing Technology7.27.3 ObjectType Description7.27.3 ObjectType Description CurrentPieceCount defines the number of pieces that
-
OPC-40200 – OPC UA for Weighing Technology7.29.3 ObjectType Description7.29.3 ObjectType Description Recipes is an object of the Type
-
OPC-40200 – OPC UA for Weighing Technology7.42.3 ObjectType Description7.42.3 ObjectType Description ProductionPreset, which is inherited from ScaleDeviceType shall