18.46 WireReception
A WireReception is the area of a terminal where the contacting with a wire element (e.g. by crimping) takes place. This class represents such an area on the terminal. Its description is done with a WireReceptionSpecification, which is independent from the TerminalSpecification. This allows the reuse of the specification of similar WireReception on different terminals.
The structure is defined in Table 133.
| VEC Name | Type | Description | Allow Subtypes |
|---|---|---|---|
| WireReception | structure | Subtype of ExtendableElement defined in VEC | |
Identification | String | Specifies a unique identification of the WireReception. The identification is guaranteed to be unique within the TerminalSpecification (this might be for example a reception number). A WireReception is the area of a terminal where the contacting with a wire element (e.g. by crimping) takes place. This class represents such an area on the terminal. Its description is done with a WireReceptionSpecification, which is independent from the TerminalSpecification. This allows the reuse of the specification of similar WireReception on different terminals. | False |
Rotation | NumericalValue | Defines the rotation of a WireReception relative to the TerminalReception. The rotation of the WireReception is the angle between the normal vector on base plane of the crimp area and the y-axis, which is a rotation around the z-axis (right hand rule, compare illustration in "Terminal Coordinate System" ). A WireReception is the area of a terminal where the contacting with a wire element (e.g. by crimping) takes place. This class represents such an area on the terminal. Its description is done with a WireReceptionSpecification, which is independent from the TerminalSpecification. This allows the reuse of the specification of similar WireReception on different terminals. | False |
WireReceptionSpecification | WireReceptionSpecification | References the WireReceptionSpecification that specifies the WireReception. A WireReception is the area of a terminal where the contacting with a wire element (e.g. by crimping) takes place. This class represents such an area on the terminal. Its description is done with a WireReceptionSpecification, which is independent from the TerminalSpecification. This allows the reuse of the specification of similar WireReception on different terminals. | False |