18.45 WireMountingDetail
With a WireMountingDetail it is possible to describe a detailed wire mounting. This is needed if the information which wire end is mounted onto which wire reception is important (e.g. coax contacts).
The structure is defined in Table 132.
| VEC Name | Type | Description | Allow Subtypes |
|---|---|---|---|
| WireMountingDetail | structure | Subtype of ExtendableElement defined in VEC | |
CoreCrimpSize | Size | Defines the required core crimp size (width & height) of this specific wire mounting situation. With a WireMountingDetail it is possible to describe a detailed wire mounting. This is needed if the information which wire end is mounted onto which wire reception is important (e.g. coax contacts). | False |
InsulationCrimpSize | Size | Defines the required insulation crimp size (width & height) of this specific wire mounting situation. With a WireMountingDetail it is possible to describe a detailed wire mounting. This is needed if the information which wire end is mounted onto which wire reception is important (e.g. coax contacts). | False |
WireTipProtrusion | ValueRange | Defines the valid length range in which the protrusion of the conductor from the conductor crimp must be located. With a WireMountingDetail it is possible to describe a detailed wire mounting. This is needed if the information which wire end is mounted onto which wire reception is important (e.g. coax contacts). | False |
ContactedWireReception | WireReceptionReferenceIdDataType | References the WireReception that is used for the WireMounting. With a WireMountingDetail it is possible to describe a detailed wire mounting. This is needed if the information which wire end is mounted onto which wire reception is important (e.g. coax contacts). | False |
ReferencedWireEnd | WireEndIdDataType | References the WireEnds that are mounted to referenced WireReception. A cardinality of more than one is allowed in order support parallel connectors, where multiple wire ends are placed on one side of the connector (one wire reception) and the other wire ends are placed on the other side of the connector (the other wire reception). With a WireMountingDetail it is possible to describe a detailed wire mounting. This is needed if the information which wire end is mounted onto which wire reception is important (e.g. coax contacts). | False |
AbsoluteSealPosition | NumericalValue | The absoluteSealPosition defines distance between the conductor tip and edge of the CavitySeal facing the conductor tip. With a WireMountingDetail it is possible to describe a detailed wire mounting. This is needed if the information which wire end is mounted onto which wire reception is important (e.g. coax contacts). | False |
CorePullOffForce | NumericalValue | The minimum force that the completed crimp (core crimp only, insulation crimp non-functional) should withstand when wire is being pulled off the terminal. Above that force, the crimp can be expected to be destroyed at any time. With a WireMountingDetail it is possible to describe a detailed wire mounting. This is needed if the information which wire end is mounted onto which wire reception is important (e.g. coax contacts). | False |