Search
175 result(s) for Profiles
-
OPC-10000-1 – OPC Unified Architecture - Part 1: Overview and Conceptstransport protocols and data encodings supported by OPC UA. Part 7 ( OPC 10000-7 ) - Profiles Part 7 specifies the Profiles that are available for OPC UA Applications. These Profiles provide ... used for conformance level certification. OPC UA Applications will be tested against the Profiles . Part 8 ( OPC 10000-8 ) - Data Access Part 8 specifies
-
OPC-10000-1 – OPC Unified Architecture - Part 1: Overview and Concepts4.3 Design goalssubset of these capabilities. To promote interoperability, OPC UA defines subsets, referred to as Profiles , to which Servers may claim conformance. Clients can then discover the Profiles of a Server ... tailor their interactions with that Server based on the Profiles . Profiles are defined in OPC 10000-7 . The OPC UA is layered to isolate the core design from the underlying
-
OPC-10000-1 – OPC Unified Architecture - Part 1: Overview and Concepts4.4.1.1 Generalthese parameters is not. This framework also defines a minimum set of security Profiles that all OPC UA Applications support, a subset of which can be enabled in each installation ... Profiles are defined
-
OPC-10000-1 – OPC Unified Architecture - Part 1: Overview and Concepts5.3.4.2 AddressSpace organizationdefines OPC UA Nodes and References and their expected organization in the AddressSpace . Some Profiles will not require that all of the UA Nodes be implemented
-
OPC-10000-1 – OPC Unified Architecture - Part 1: Overview and Concepts5.4 Redundancywhat Redundancy is supported by an OPC UA Application is defined by its Profiles . Profiles are described in OPC 10000-7 . Required Client and Server behaviours are associated with
-
OPC-10000-1 – OPC Unified Architecture - Part 1: Overview and Concepts6.1 Generalavailability of specific Service Sets and the Services within them depends on the Profiles supported by the Server . Profiles are described
-
OPC-10000-2 – OPC Unified Architecture - Part 2: Security Model4.5.2.3 Session communication layermeet the OPC UA security objectives. Other details are provided as part of Profiles which are described in OPC 10000-7 (and available on-line at OPC Security Policies
-
OPC-10000-2 – OPC Unified Architecture - Part 2: Security ModelSecurity Profiles OPC UA Client and Server products are certified against Profiles that are described in OPC 10000-7 . Some of the Profiles specify security functions and others specify other ... functionality that are not related to security. The Profiles impose requirements on the certified products but they do not impose requirements on how the products are used. A consistent minimum
-
OPC-10000-2 – OPC Unified Architecture - Part 2: Security Modelsecurity Profile None. Security mode "none" is disabled for all other security Profiles . Profile None shall be disabled by default. The choice of "Sign
-
OPC-10000-2 – OPC Unified Architecture - Part 2: Security Modelenabled. It is recommended to only support TLS configurations provided in the TransportSecurity Profiles . SSL has security issues and should be disabled. It is important that it is disabled
-
OPC-10000-2 – OPC Unified Architecture - Part 2: Security Model9.1 Overviewcertificate since more than one certificate could be required depending on the Security Profiles that are being supported. Asymmetric Cryptography makes use of two keys - a Private
-
OPC-10000-2 – OPC Unified Architecture - Part 2: Security Modeltopic that does apply the table lists the relevant OPC UA Parts and the Profiles / ConformanceUnits that covers the listed functionality. For each OPC UA Part that is listed (other ... column contains the actual ConformanceUnits that apply. For the row labelled OPC 10000-7 - Profiles, the keyword column contains the actual Profiles/Facets that apply. For more detail on the ConformanceUnit
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services1 Scopewill need to implement all of the defined Services . OPC 10000-7 defines the Profiles that dictate which Services need to be implemented in order to be compliant with
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.1 GeneralService Set , or a Service within a Service Set , is defined by its Profile . Profiles are described
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.5.4.1 Descriptionalso specifies a URI for the Transport Profile that the Endpoint supports. The Transport Profiles specify information such as message encoding format and protocol version and are defined ... algorithms used depends on the SecurityPolicy for the Endpoint . OPC 10000-7 defines Profiles for common SecurityPolicies and assigns a unique URI to them. It is expected that applications have
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.5.4.2 Parametersthat the returned Endpoints shall support. OPC 10000-7 defines URIs for the Transport Profiles . All Endpoints are returned if the list is empty ... this URL may have a query string appended. The Transport Profiles that support query strings are defined in OPC 10000-7 . Response responseHeader ResponseHeader Common response parameters. The ResponseHeader type
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.7.2.1 Descriptionidentifies the capabilities of the Server and also contains the list of OPC UA Profiles supported by the Server . OPC UA Profiles are defined in OPC 10000-7 . Additional Certificates ... other organizations may be included to identify additional Server capabilities. Examples of these Profiles include support for specific information models and support for access to specific types of devices. When
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.14.1.4 FunctionsTransferSubscriptions request is operating on behalf of the same user and supports the same Profiles as the Client of the previous Session . CreateNotificationMsg() Increment the SeqNum and create a NotificationMessage
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.14.7.3 Service resultsInsufficientClientProfile The Client of the current Session does not support one or more Profiles that are necessary for the Subscription
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services7.14 EndpointDescriptionTransport Profile supported by the Endpoint . OPC 10000-7 defines URIs for the Transport Profiles . securityLevel Byte A numeric value that indicates how secure the EndpointDescription is compared to other
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Servicesenabled. In this cases, the SessionAuthenticationToken is a NodeId with a ByteString identifier. The Profiles in OPC 10000-7 may define additional requirements for a ByteString SessionAuthenticationToken. Client and Server
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model6.3.1 ServerTypeTRUE if the Server generates audit events, otherwise to false. The Profiles defined in OPC 10000-7 specify what kind of audit events are generated by the Server . EstimatedReturnTime indicates
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model6.3.2 ServerCapabilitiesTypeHasProperty Variable ConformanceUnits QualifiedName[] PropertyType Optional Conformance Units Base Info ServerType ServerProfileArray lists the Profiles that the Server supports. The String shall be the URI of the Profile ... definitions of OPC UA Server Profiles . This list should be limited to the Profiles the Server supports in its current configuration. LocaleIdArray is an array of LocaleIds that are known
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model6.4.27 AuditUpdateMethodEventTypeServer . Note: This Property is optional for backward compatibility and required by Profiles starting with version 1.05. InputArguments provide the values of the input arguments passed to the Method . This ... arguments were returned. Note: This Property is optional for backward compatibility and required by Profiles starting with version
-
OPC-10000-6 – OPC Unified Architecture - Part 6: Mappingscalled a SecurityPolicy . OPC 10000-7 defines standard SecurityPolicies as parts of the standard Profiles which OPC UA applications are expected to support. OPC 10000-7 also defines ... each standard SecurityPolicy . The latest versions of all SecurityPolicies are available in the online Profiles website. OPC 10000-7 defines the link to this website. A Stack is expected
-
OPC-10000-6 – OPC Unified Architecture - Part 6: Mappingsthat maps the domain name onto a usable network address. OPC 10000-7 defines Profiles for different name resolution protocols that Clients and Servers may support. If the Client creates
-
OPC-10000-6 – OPC Unified Architecture - Part 6: Mappingslist of SecurityPolicyUris supported by a Server. The URIs are defined as security Profiles in OPC 10000-7 . Applications allow these values to be read or changed. Applications allow
-
OPC-10000-7 – OPC Unified Architecture - Part 7: Profiles1 ScopeScope This document specifies value and structure of Profiles in the OPC Unified Architecture. The actual Profiles are maintained in an online database and accessible via https://profiles.opcfoundation.org ... Profiles are used to segregate features with regard to testing of OPC UA products and the nature of the testing (tool based or lab based). This includes the testing performed
-
OPC-10000-7 – OPC Unified Architecture - Part 7: Profiles3.1.5 Facetrequire Note 1 to entry: Facets are typically combined to form higher-level Profiles . The use of the term Facet in the title of a Profile indicates that the given
-
OPC-10000-7 – OPC Unified Architecture - Part 7: Profiles4.1 Generalthese features. The individual features are grouped into ConformanceUnits which are further grouped into Profiles . Figure 1 provides an overview of the interactions between Profiles , ConformanceUnits and TestCases . The large ... that are used to construct the parent. For example a Profile is constructed from Profiles and ConformanceUnits . The figure also illustrates a feature of the OPC UA Compliance Test Tool
-
OPC-10000-7 – OPC Unified Architecture - Part 7: Profiles4.3 ProfilesProfiles A Profile is a named aggregation of ConformanceUnits and other Profiles . To support a Profile , an application has to support the ConformanceUnits and all aggregated Profiles . The definition ... Profiles is an ongoing activity, in that it is expected that new Profiles will be added in the future. Multiple Profiles may include the same ConformanceUnit . Testing of a Profile
-
OPC-10000-7 – OPC Unified Architecture - Part 7: ProfilesProfile Categories Profiles are grouped into categories to help vendors and end users understand the applicability of a Profile . Table 1 contains the list of currently defined ProfileCategories . Table ... Profile Categories Category Description Application Profiles Application level Profiles represent a collection of Facets necessary to build a functional OPC UA Application.They specifically include Transport Profiles and generally also Security
-
OPC-10000-7 – OPC Unified Architecture - Part 7: Profilesmandatory ConformanceUnits in a Profile in order to be compliant with the Profile . Some Profiles contain optional ConformanceUnits . Optional means that an application has the option to not support ... ConformanceUnits and whether they are supported or not by the tested OPC UA application. Profiles may also include other Profiles . If a Profile is included it means that
-
OPC-10000-7 – OPC Unified Architecture - Part 7: ProfilesConventions for Profile definitions Profiles have the following naming conventions: Profiles intended for specific application types have the application type in their titles. Currently defined application types are Server, Client ... Profile indicates that this Profile concerns a specific feature of OPC UA. Such Profiles are expected to be combined with Application Profiles to define the complete functionality
-
OPC-10000-7 – OPC Unified Architecture - Part 7: Profiles4.8 Applicationsvendor that is developing an OPC UA application, shall review the list of available Profiles . From this list the vendor shall select the Profiles that include the functionality required ... single Profile may not yield a complete application. In most cases multiple Profiles are needed to yield a useful application. All UA applications shall support at least one Application Profile
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access4.5 TimestampsServers will support historizing SourceTimestamp (see OPC 10000-7 for details on Server Profiles ). If a request is made requesting both ServerTimestamp and SourceTimestamp and the Server is only collecting
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.3.2.1 Generalthat maps the domain name onto a usable network address. OPC 10000-7 defines Profiles for different name resolution protocols that Publisher or Subscriber may support
-
OPC-10000-80 – OPC Unified Architecture - Part 80: UAFX Overview and Concepts4.2 Architecturealso adds definitions for network services and component models for End Stations and Bridges. Profiles defining the selection of specific networking services supported by these component models are specified ... communication layer - see OPC 10000-15 for details on the OPC safety communication layer. Profiles will be developed in the future for Motion, I/O, and many types of process instruments
-
OPC-10000-80 – OPC Unified Architecture - Part 80: UAFX Overview and Concepts6.5 ProfilesProfiles A Profile is a named aggregation of ConformanceUnits and other Profiles ( OPC 10000-7 ). UAFX Profiles are defined in OPC 10000-84 . All OPC UA AutomationComponents will support ... more Profiles and any or all of its optional Facets
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelincludes many optional items. Some of these items are mandatory for controller-level Profiles but optional for embedded device Profiles . For a complete list of Profiles related
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelE.4.7 PubSub DataSetsplease see OPC 10000-14 . PubSub communication has multiple options that are defined by Profiles . To see what is defined in UAFX for a controller or device, see the UAFX ... defined Profiles in the Profile database. When setting up communication between controllers, between a device and a controller, or even between devices, the engineering tool must ensure that the PubSub
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelE.6.1 OverviewPeriodic-Fixed as the header layout Profile . Details for other transport or header layout Profiles could be added in a later version of this document
-
OPC-10000-83 – OPC Unified Architecture - Part 83: UAFX OfflineEngineering7.3.3 Information Model filescontent of the Descriptor shall correspond to the online UAFX Information Model Profiles as described in the UAFX Offline Descriptor Profile (see OPC 10000-84 and http://opcfoundation.org/UA-Profile/UAFX-Offline-Descriptor-Profile ). Information
-
OPC-10000-83 – OPC Unified Architecture - Part 83: UAFX OfflineEngineering7.8.1 Generalsigning certificate shall be included. Descriptors shall only use cryptographic mechanisms from OfflineEngineering security Profiles defined in OPC 10000-84 . Descriptor signatures shall be validated as specified in ISO/IEC
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles1 Scopepart of OPC 10000 describes the OPC Unified Architecture Field eXchange (OPC UA FX) Profiles . The Profiles in this document are used to segregate OPC UA FX features with regard ... implementing OPC UA FX functionality. This testing will be performed in the same way Profiles defined in OPC 10000‑7 are tested. Most OPC UA FX applications will conform
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles4.1 GeneralGeneral This document adds ConformanceUnits , ConformanceGroups , Profiles , and Facets grouping OPC UA FX features to the Profile Model defined
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX ProfilesProfile Categories UAFX Profiles are grouped into categories defined in OPC 10000‑7 to help vendors and end-users understand the applicability of a Profile . A Profile can be assigned ... have been added to support UAFX. Table 1 - UAFX Profile Categories Category Description Offline Profiles in this category specify functions for OfflineEngineering . Infrastructure Profiles in this category specify functions
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles6.1 Overviewcategories that a Profile can be grouped into, a list of named Profiles, and the detailed listing of each Profile, including directly defined ConformanceUnits and any sub- Profiles included ... Profile . Subclauses in 6.6 describe Profiles in a tabular format
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles6.2 Profile listProfile list Table 15 lists UAFX Profiles . The Profile table is ordered by in the order they appear in this document. The table includes a list of categories the Profile ... used to uniquely identify a Profile . The compliance of a product related to these Profiles is described in OPC 10000‑7 . Table 15 - Profile list Profile Related Category URI UAFX
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX ProfilesConventions for Profile definitions The Profiles defined in this document shall follow the naming conventions defined
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX ProfilesProfile versioning Versioning of the Profiles defined in this document shall follow the rules defined
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles6.5 ApplicationsApplications Figure 1 illustrates the Profiles and Facets that make up a UAFX Controller application. Figure 1 - Structure of the UAFX Profiles
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles6.6.4.1 OverviewFigure 7 , Figure 8 , and Figure 9 illustrate the structure of UAFX Controller Profiles and Facets . Figure 6 - Structure of the UAFX Server Profile Figure 7 - Structure of the UAFX
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles6.6.4.10 UAFX Controller 2024 Profiledetails of the UAFX Controller 2024 Profile. This Profile is a collection of Profiles and Facets necessary to build a functional UAFX Controller , including a ConnectionManager . This Profile supersedes
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles6.6.5.1 OverviewOverview This clause defines Profiles and Facets for the UAFX OfflineEngineering illustrated in Figure 12 , Figure 11 , and Figure 12 . Figure 10 - Structure of the OfflineEngineering Descriptor Profile Figure
-
OPC-10000-100 – OPC Unified Architecture - Part 100: DevicesProfiles and ConformanceUnits Meaning and significance of Profiles and ConformanceUnits are described in OPC 10000-7 . The Profiles and ConformanceUnits for this specification are maintained in the online database
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basics6.1 Generalother, for example the identification of an asset is needed in most cases, the Profiles defined in section 15.2 combine the ConformanceUnits to functionality that is required to be provided
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basicsspecification does not define or require a specific ObjectType or Interface , but ConformanceUnits and Profiles referencing mandatory and optional Properties as defined in OPC 10000-100 . The Properties defined
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basicssupported OPC UA functionality in the ServerCapabilites Object , like the supported OPC UA Profiles in the ServerProfileArray . The corresponding ConformanceUnit is already defined in OPC 10000-7 . Therefore, this specification
-
OPC-10000-210 – OPC Unified Architecture - Part 210: Relative Spatial Location9.2.3.2 RSL Base Client Profilecharacteristics for all OPC UA Clients that make use of this companion specification. Additional Profiles will define support for various information models that are part of this document. Table
-
OPC-10000-210 – OPC Unified Architecture - Part 210: Relative Spatial LocationConformanceUnits of the RSL concept, as defined in the RSL CartesianFrameAngleOrientation Profile ( 9.2.2.2 ), new Profiles can be created to represent spatial relationships in other formats
-
OPC-10000-211 – OPC Unified Architecture - Part 211: Global Positioning4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionalities
-
OPC-10000-211 – OPC Unified Architecture - Part 211: Global PositioningProfiles and Conformance Units Meaning and significance of Profiles and ConformanceUnits are described in OPC 10000-7 . The Profiles and ConformanceUnits for this specification are maintained in an online database
-
OPC-10031-4 – OPC UA for ISA-95 - Part 4: Job ControlProfiles and Conformance Units Profiles and ConformanceUnits break functionality into testable groups. A ConformanceUnit describes a testable unit. A single ConformanceUnit is tested as a unit so all items covered ... must be supported or the ConformanceUnit will fail. ConformanceUnits can be included in multiple Profiles, so they are declared in their own table
-
OPC-10100-1 – OPC UA for WoT Connectivity - Part 1: API Definition4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality but generate requirements for a minimum set of functionalities
-
OPC-10100-1 – OPC UA for WoT Connectivity - Part 1: API DefinitionProfiles and Conformance Units Meaning and significance of Profiles and ConformanceUnits are described in OPC 10000-7 . The Profiles and ConformanceUnits for this specification are maintained in the online database
-
OPC-10101 – OPC UA for WoT Binding4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionalities
-
OPC-30000 – OPC UA for Programmable Logic Controllers based on IEC61131-34.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionalities
-
OPC-30000 – OPC UA for Programmable Logic Controllers based on IEC61131-3Conformance Units and Profiles This chapter defines the corresponding Profiles and Conformance Units for the OPC UA Information Model for IEC61131-3. Profiles are named groupings of Conformance Units . Facets ... Profiles that will be combined with other Profiles to define the complete functionality of an OPC UA Server or Client
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices6.1.1 Generalsupported. See also 10.1 for the definition of the different AutoID Device Profiles
-
OPC-30020 – MDIS OPC UA Companion SpecificationServer or Client fulfils all functionality that it claims to support in terms of Profiles and that of all exposed interfaces function as defined in the specifications. Interoperability - Testing
-
OPC-30020 – MDIS OPC UA Companion Specification4.1 MDIS definitionsthan one Profile . The OPC Foundation provides a base list of Server and Client Profiles and Facets in an online database which is also documented in an OPC UA specification
-
OPC-30020 – MDIS OPC UA Companion Specification4.3.4.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the development of companion specifications ... that can describe the subset of functionality that is expected to be implemented. The Profiles do not restrict functionality but generate requirements for a minimum set of functionality
-
OPC-30020 – MDIS OPC UA Companion SpecificationHanding off Valve Profiles / Signatures Valve Profiles are made available for transmission from the SCV system. The output format may vary among vendors and the data may be transmitted according
-
OPC-30020 – MDIS OPC UA Companion Specificationfrom what is described in this specification, which includes support for any Mandatory items. Profiles are described in section 14.3 . Fault - The status of the object, true if any fault
-
OPC-30020 – MDIS OPC UA Companion Specification14.1 Test requirementsTest requirements All mandatory Profiles shall be certified and any optional Profiles that are supported should be certified by an OPC Foundation certification authority (see 2.4 for additional details
-
OPC-30020 – MDIS OPC UA Companion Specification14.3.2.1 MDIS Base Functionality Server FacetFunctionality False MDIS Base MDIS Information Version True This Profile includes a number of Profiles and ConformanceUnits
-
OPC-30020 – MDIS OPC UA Companion Specification14.3.3.1 MDIS Base Client Facetcharacteristics for all OPC UA Clients that make use of this companion specification. Additional Profiles will define support for various object models that are part of this specification. Table
-
OPC-30020 – MDIS OPC UA Companion Specification14.4.1 OverviewClient are expected to combine and utilise in an application. The following Profiles provide a recommended combination of functionality that a Server or Client should include. These are complete Profiles ... that include all required Profiles and ConformanceUnits to implement a Server or a Client
-
OPC-30020 – MDIS OPC UA Companion SpecificationClient . The OPC UA Client may expose additional functionality as separate Profiles . Table 173 - MDIS Solution Client 1.3 Profile Group Conformance Unit / Profile Title Optional Profile MDIS Base Functionality Client
-
OPC-30020 – MDIS OPC UA Companion SpecificationServer . The OPC UA Server may expose additional functionality as Profiles . Table 174 - MDIS Solution Server 1.3 Profile Group Conformance Unit / Profile Title Optional Profile MDIS Base Functionality Server Facet
-
OPC-30020 – MDIS OPC UA Companion Specificationcases defined by MDIS. The certification documentation shall include a list of valid MDIS Profiles and optional ConformanceUnits for which the vendor equipment is certified, vendor equipment information used
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information ModelProfiles and Conformance Units This chapter defines the corresponding profiles and conformance units for the OPC UA Information Model for BACnet. Profiles are named groupings of conformance units. Facets ... profiles that will be combined with other Profiles to define the complete functionality of an OPC UA Server or Client. The following tables specify the facets available for Servers that
-
OPC-30040 – OPC UA for AutomationML - Xxx: OPC UA Information Model for AutomationMLConformance Units and Profiles This chapter defines the corresponding profiles and conformance units for the OPC UA Information Model for AutomationML. Profiles are named groupings of conformance units. Facets ... profiles that will be combined with other Profiles to define the complete functionality of an OPC UA Server or Client. Table 129 specify the facet available for Servers that implement
-
OPC-30050 – OPC UA for PackML - Common Object Model: PackMLTagID True PackML Model PackML Base Version True This Profile includes a number of Profiles and ConformanceUnits
-
OPC-30050 – OPC UA for PackML - Common Object Model: PackML7.2.3.1 PackML Base Client Facetcharacteristics for all OPC UA Clients that make use of this companion specification. Additional Profiles will define support for various object models that are part of this specification. Table
-
OPC-30060 – OPC UA for Tobacco Machine Communication4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-30081 – OPC UA for Process Automation Devices - PA-DIM™Profiles and Conformance Units Meaning and significance of Profiles and ConformanceUnits are described in OPC 10000-7. The Profiles and ConformanceUnits for this specification are maintained in an online database
-
OPC-30090 – OPC UA for Field Device Tool (FDT) - Part <mm>: <Part Name>4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-30090 – OPC UA for Field Device Tool (FDT) - Part <mm>: <Part Name>13.2.3.2 FDT General Client Facetcharacteristics for all OPC UA Clients that make use of this companion specification. Additional Profiles will define support for various information models that are part of this document. Table
-
OPC-30100 – OPC UA for SERCOS DevicesConformance Units and Profiles This chapter defines the corresponding profiles and conformance units for the OPC UA Information Model for Sercos. Profiles are named groupings of conformance units. Facets ... profiles that will be combined with other Profiles to define the complete functionality of an OPC UA Server or Client. Table 12 defines a facet that indicates full support defined
-
OPC-30110 – OPC UA for POWERLINK - POWERLINK: OPC Unified ArchitectureConformance Units and Profiles This chapter defines the corresponding profiles and conformance units for the OPC UA Information Model for POWERLINK Profiles are named groupings of conformance units. Facets ... profiles that will be combined with other Profiles to define the complete functionality of an OPC UA Server or Client. The following tables specify the facets available for Servers that
-
OPC-30130 – OPC UA for Control & Communication System Profile(for Machine)Conformance Unit and Profile This section defines the profiles and conformance units of the OPC UA information model which are related to CSP+ for machine. Profiles are defined ... Profile which is to be a Facet is expected to be combined with other Profiles to define full functions of the OPC UA Server or Client . Table 9‑2 shows
-
OPC-30140 – OPC UA for PROFINET4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionalities
-
OPC-30140 – OPC UA for PROFINETConformance Units and Profiles This chapter defines the corresponding Profiles and Conformance Units for the OPC UA Information Model for PROFINET. Profiles are named groupings of Conformance Units . Facets ... Profiles that will be combined with other Profiles to define the complete functionality of an OPC UA Server or Client
-
OPC-30141 – OPC UA for PROFIenergy4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-30142 – OPC UA for PROFINET Remote IO4.3.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-30142 – OPC UA for PROFINET Remote IO12.2.2.2 PNRIO Common Server FacetPNRIO Common Server Facet The PNRIO Common Server Facet contains all Conformance Units and Profiles which are used by the other Profiles . It is intended to be used only ... part of the subsequent defined Profiles . Table 137 - PNRIO Common Server Facet Group Conformance Unit / Profile Title Mandatory / Optional PNRIO PNRIO Alarms O PNRIO PNRIO Events O PNRIO PNRIO Durable
-
OPC-30143 – OPC UA for PROFINET Encoder - Part <mm>: <Part Name>4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Model4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionalities
-
OPC-30145 – OPC UA for PROFINET Drives - Part 30145: UA CS for PROFINET Drives4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-30145 – OPC UA for PROFINET Drives - Part 30145: UA CS for PROFINET Drives10.2.2.1 Overviewdescribes a Facet or Profile . Figure 28 shows the intended usage of the specified Profiles . Figure 28 - PDRV Server Profiles Intended Usage
-
OPC-30200 – OPC UA for Commercial Kitchen Equipment4.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-30200 – OPC UA for Commercial Kitchen EquipmentConformance Units and Profiles This chapter defines the corresponding Profiles and Conformance Units for the OPC UA Information Model for commercial kitchen devices. Profiles are named groupings of Conformance Units ... Facets are Profiles that will be combined with other Profiles to define the complete functionality of an OPC UA Server or Client
-
OPC-30250 – OPC Unified Architecture for DEXPI5.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-30260 – OPC UA for OPEN-SCS - Serialization Object Model: OPEN-SCSProfiles and Facets Profiles are named groupings of Conformance Units . Facets are Profiles that will be combined with other Facets or Profiles to define the complete functionality ... Server or Client. The following tables specify the Profiles and Facets available for components (physical or virtual) that implement the OPEN-SCS PSS specification. Some Conformance Units . Facets and Profiles
-
OPC-30260 – OPC UA for OPEN-SCS - Serialization Object Model: OPEN-SCS7.4.1.1 OPENSCS Security Server FacetConformanceUnits for Servers that are not included in other OPC UA defined Facets and Profiles . This Facet is required to meet the security requirements of OPENSCS. Table 72 - OPENSCS Security
-
OPC-30260 – OPC UA for OPEN-SCS - Serialization Object Model: OPEN-SCS7.4.3.1 OPENSCS Base Client ProfileBase Client Profile The OPENSCS Client Profile defined in Table 85 includes Facets and Profiles that define the minimum functionality necessary for a component that conforms to the functionality ... using the OPC UA Client/Server Interface. Table 85 - OPENSCS Client Profile Definition Facets and Profiles Defined in Optional / Mandatory Standard UA Client 2017 Profile . OPC 10000-7 M Documentation - Client
-
OPC-30270 – OPC UA for Asset Administration Shell (AAS)4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionalities
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: Basics4.2.3.1 Conceptssupport all functionalities in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. Profiles do not restrict functionality, but they generate requirements for a minimum set of functionalities
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: Basics9.2.2 Profile listProfile list Table 134 lists all Profiles defined in this document and defines their URIs. Table 134 - Profile URIs for LADS Profile URI LADS BaseServer Server Profile http://opcfoundation.org/UA-Profile/
-
OPC-34100 – OPC UA for Energy Consumption Management4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionalities
-
OPC-40001-1 – OPC UA for Machinery - Part 1: Basic Building Blocks4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-40001-1 – OPC UA for Machinery - Part 1: Basic Building Blocks19.2.1 Profile listProfile list Table 53 lists all Profiles defined in this document and defines their URIs. Table 53 - Profile URIs for OPC UA for Machinery Profile URI Machinery Machine Identification Server
-
OPC-40010-1 – OPC UA for Robotics - Part 1: Vertical Integration4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality but generate requirements for a minimum set of functionality
-
OPC-40020-1 – OPC UA for Cranes and Hoists - Part 1: Base Model Motion Devices System4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-40077 – OPC UA interfaces for plastics and rubber machinery - Data exchange between injection moulding machines and MESProfiles and Conformance Units This chapter defines the corresponding profiles and conformance units for the OPC UA Information Model for OPC 40077. Profiles are named groupings of conformance units. Facets ... profiles that will be combined with other Profiles to define the complete functionality of an OPC UA Server or Client. The following tables specify the facets available for Servers that
-
OPC-40082-1 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 1: Temperature control devicesProfiles and Conformance Units This chapter defines the corresponding profiles and conformance units for the OPC UA Information Model for OPC 40082-1. Profiles are named groupings of conformance units ... Facets are profiles that will be combined with other Profiles to define the complete functionality of an OPC UA Server or Client. The following tables specify the facets available
-
OPC-40082-2 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 2: Hot runner devicesProfiles and Conformance Units This chapter defines the corresponding profiles and conformance units for the OPC UA Information Model for OPC 40082-2. Profiles are named groupings of conformance units ... Facets are profiles that will be combined with other Profiles to define the complete functionality of an OPC UA Server or Client. The following tables specify the facets available
-
OPC-40082-3 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 3: LSR Dosing SystemsProfiles and Conformance Units This chapter defines the corresponding profiles and conformance units for the OPC UA Information Model for OPC 40082-3. Profiles are named groupings of conformance units ... Facets are profiles that will be combined with other Profiles to define the complete functionality of an OPC UA Server or Client
-
OPC-40082-4 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 4: Dosing SystemsProfiles and Conformance Units This chapter defines the corresponding profiles and conformance units for the OPC UA Information Model for OPC 40082-4. Profiles are named groupings of conformance units ... Facets are profiles that will be combined with other Profiles to define the complete functionality of an OPC UA Server or Client
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type DefinitionsProfiles and Conformance Units This specification does not define Profiles and Conformance Units . They are defined by the specific Companion Specifications for the several machine types
-
OPC-40084-1 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 1: General Type Definitions10.2.1 Profile listProfile list Table 19 lists all Profiles defined in this document and defines their URIs. Table 19 - Profile URIs for OPC UA for Machinery Profile URI Extrusion v2 Extrusion Device
-
OPC-40084-2 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 2: Extrusion Line10.2.1 Profile listProfile list Table 33 lists all Profiles defined in this document and defines their URIs. Table 33 - Profile URIs for OPC 40084-2 Profile URI OPC 40084-2 v2 Basic ... available in the instance of the ExtrusionLine_InterfaceType . NOTE: The names of the supported profiles are available in the Server Object under ServerCapabilities.ServerProfileArray
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoring4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionalities
-
OPC-40200 – OPC UA for Weighing Technology4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a Companion Specification. The Profiles do not restrict functionality but generate requirements for a minimum set of functionalities
-
OPC-40200 – OPC UA for Weighing Technology12.1 Conformance UnitsStandard DataChange Subscription Facet of OPC UA 10000-7 This section defines the corresponding Profiles and Conformance Units for the OPC UA Information Model for Weighing Technology. Profiles are named ... groupings of Conformance Units . Facets are Profiles that will be combined with other Profiles to define the complete functionality of an OPC UA Server or Client
-
OPC-40200 – OPC UA for Weighing Technology12.2.1 Profile listProfile list Table 163 lists all Profiles defined in this document and defines their URIs. Table 163 - Profile URIs for Weighing Technology Profile URI Scales V2 Base Scale Server Facet
-
OPC-40210 – OPC UA for Geometric Measurement Systems5.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionalities
-
OPC-40223 – OPC UA for Pumps and Vacuum Pumps4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems9.2.1 OverviewOverview Table 163 lists all Facets and Profiles defined in this document and defines their URIs. Table 163 - Facet and Profile URIs for OPC UA for Compressed Air Systems Profile
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems9.2.2.1 OverviewOverview The following sections define the Facets and Profiles available for Servers that implement the OPC UA for Compressed Air Systems companion specification
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems9.2.3.1 OverviewOverview The following sections define the Facets and Profiles available for Clients that implement the OPC UA for Compressed Air Systems companion specification
-
OPC-40301 – OPC UA for Flat Glass Processing4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-40301 – OPC UA for Flat Glass Processing9.1 OverviewOverview Meaning and significance of Profiles and ConformanceUnits are described in OPC 10000-7 . The Profiles and ConformanceUnits for this specification are also found in an online database which
-
OPC-40400-1 – OPC UA for the Powertrain - Part 1: Asset Management4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-40444 – OPC UA for Textile Testing Devices4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-40450-1 – OPC UA for Joining Systems - Part 1: Base4.3.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job Management4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job Management14.2.2.1 OverviewOverview The following sections specify the Facets and Profiles available for Servers that implement the Machine Tools companion specification. Each section defines and describes a Facet or Profile
-
OPC-40502 – OPC UA for Computerized Numerical Control (CNC) Systems - for CNC Systems: OPC UA Information ModelConformance Units and Profiles This chapter defines the corresponding Profiles and Conformance Units for the "OPC UA Information Model for CNC Systems". Profiles are named groupings of Conformance ... Units . Facets are Profiles that will be combined with other Profiles to define the complete functionality of an OPC UA Server or Client. The following tables specify the facets available
-
OPC-40503-1 – OPC UA for Metal Forming - Part 1: General4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-40504-1 – OPC UA for Cutting Tools - Part 1: Manufacturing4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionalities
-
OPC-40504-1 – OPC UA for Cutting Tools - Part 1: Manufacturing10.2.3.2 CuttingTool Basic Client Facetcharacteristics for all OPC UA Clients that make use of this companion specification. Additional Profiles will define support for various information models that are part of this document. Table
-
OPC-40505 – OPC UA for Wireless Machine Tool Peripherals4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-40530 – OPC UA for Laser Systems4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-40540 – OPC UA for Additive Manufacturing4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality but generate requirements for a minimum set of functionality
-
OPC-40540 – OPC UA for Additive Manufacturing12.2.2.1 OverviewOverview The following sections specify the Facets and Profiles available for Servers that implement the Additive Manufacturing companion specification. Each section defines and describes a Facet or Profile
-
OPC-40550-1 – OPC UA for Woodworking Machines - Part 1: Vertical Interface4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-40560 – OPC UA for Mining - General4.3.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-40560 – OPC UA for Mining - GeneralProfiles and Conformance Units This chapter defines the corresponding profiles and conformance units for the OPC UA Information Model for OPC 40560. Profiles are named groupings of conformance units. Facets ... profiles that will be combined with other Profiles to define the complete functionality of an OPC UA Server or Client. The following tables specify the facets available for Servers that
-
OPC-40560 – OPC UA for Mining - General10.2.2.2 Mining Core Server Facetmeaningful OPC UA CS Mining Information Models and purely serves to describe the fundamental Profiles and Facets required for basic Server operation. This Facet also includes Facets from other
-
OPC-40561-2 – OPC UA for Mining - Extraction - Part 2: Shearer LoaderProfiles and Conformance Units This chapter defines the corresponding profiles and conformance units for the OPC UA Information Model for OPC 40561-2. Profiles are named groupings of conformance units ... Facets are profiles that will be combined with other Profiles to define the complete functionality of an OPC UA Server or Client. The following tables specify the facets available
-
OPC-40562-1 – OPC UA for Mining - Loading - Part 1: GeneralProfiles and Conformance Units This chapter defines the corresponding profiles and conformance units for the OPC UA Information Model for OPC 40562-1. Profiles are named groupings of conformance units ... Facets are profiles that will be combined with other Profiles to define the complete functionality of an OPC UA Server or Client. The following tables specify the facets available
-
OPC-40562-2 – OPC UA for Mining - Loading - Part 2: Hydraulic ExcavatorProfiles and Conformance Units This chapter defines the corresponding profiles and conformance units for the OPC UA Information Model for OPC 40562-2. Profiles are named groupings of conformance units ... Facets are profiles that will be combined with other Profiles to define the complete functionality of an OPC UA Server or Client. The following tables specify the facets available
-
OPC-40563-1 – OPC UA for Mining - Transport Dumping - Part 1: GeneralProfiles and Conformance Units This chapter defines the corresponding profiles and conformance units for the OPC UA Information Model for OPC 40563-1. Profiles are named groupings of conformance units ... Facets are profiles that will be combined with other Profiles to define the complete functionality of an OPC UA Server or Client. The following tables specify the facets available
-
OPC-40563-2 – OPC UA for Mining - Transport Dumping - Part 2: Armoured Face ConveyorProfiles and Conformance Units This chapter defines the corresponding profiles and conformance units for the OPC UA Information Model for OPC 40563-2. Profiles are named groupings of conformance units ... Facets are profiles that will be combined with other Profiles to define the complete functionality of an OPC UA Server or Client. The following tables specify the facets available
-
OPC-40563-3 – OPC UA for Mining - Transport Dumping - Part 3: Rear Dump TruckProfiles and Conformance Units This chapter defines the corresponding profiles and conformance units for the OPC UA Information Model for OPC 40563-3. Profiles are named groupings of conformance units ... Facets are profiles that will be combined with other Profiles to define the complete functionality of an OPC UA Server or Client. The following tables specify the facets available
-
OPC-40564-2 – OPC UA for Mining - Mineral Processing - Part 2: Rock CrusherProfiles and Conformance Units This chapter defines the corresponding profiles and conformance units for the OPC UA Information Model for OPC 40564-2. Profiles are named groupings of conformance units ... Facets are profiles that will be combined with other Profiles to define the complete functionality of an OPC UA Server or Client. The following tables specify the facets available
-
OPC-40565-2 – OPC UA for Mining - Development Support - Part 2: Roof Support SystemProfiles and Conformance Units This chapter defines the corresponding profiles and conformance units for the OPC UA Information Model for OPC 40565-2. Profiles are named groupings of conformance units ... Facets are profiles that will be combined with other Profiles to define the complete functionality of an OPC UA Server or Client. The following tables specify the facets available
-
OPC-40565-3 – OPC UA for Mining - Development - Part 3: DozerProfiles and Conformance Units This chapter defines the corresponding profiles and conformance units for the OPC UA Information Model for OPC 40565-3. Profiles are named groupings of conformance units ... Facets are profiles that will be combined with other Profiles to define the complete functionality of an OPC UA Server or Client. The following tables specify the facets available
-
OPC-40567-2 – OPC UA for Mining - PELO Services - Part 2: Face Alignment SystemProfiles and Conformance Units This chapter defines the corresponding profiles and conformance units for the OPC UA Information Model for OPC 40567-2. Profiles are named groupings of conformance units ... Facets are profiles that will be combined with other Profiles to define the complete functionality of an OPC UA Server or Client. The following tables specify the facets available
-
OPC-40568-1 – OPC UA for Mining - External Standards - Part 1: IREDES8.2.3.2 IREDES Core Client Facetcharacteristics for all OPC UA Clients that make use of this companion specification. Additional Profiles will define support for various information models that are part of this document. Table
-
OPC-40570 – OPC UA for Wire Harness Manufacturing4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-40600 – OPC UA for Weihenstephan Standards4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-40700 – OPC UA for Surface Technology - General Types4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-40702 – OPC UA for Surface Technology - Organic Coating Technology - Material Supply Systems4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-40718 – OPC UA for Surface Technology - Shot Blasting Machinery4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-40718 – OPC UA for Surface Technology - Shot Blasting Machinery8.2.1 Profile listProfile list Table 44 lists all Profiles defined in this document and defines their URIs. Table 44 - Profile URIs for OPC UA for Shot Blasting Technology Profile URI Pressurised Shot
-
OPC-40719 – OPC UA for Plasma Surface Technology4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality
-
OPC-40719 – OPC UA for Plasma Surface Technology8.2.1 Profile listProfile list Table 60 lists all Profiles defined in this document and defines their URIs. Table 60 - Profile URIs for OPC UA for Plasma Surface Technology Profile URI PST Basic
-
OPC-40740 – OPC UA for Process Air Extraction and Filtration Systems (PAEFS)4.2.3.1 Conceptssupport all functionality in the OPC UA specifications. OPC UA includes the concept of Profiles , which segment the functionality into testable certifiable units. This allows the definition of functional subsets ... that are expected to be implemented) within a companion specification. The Profiles do not restrict functionality, but generate requirements for a minimum set of functionality