18 Profiles and Conformance Units

This chapter defines the corresponding profiles and conformance units for the OPC UA Information Model for OPC 40082-6. Profiles are named groupings of conformance units. Facets are profiles that will be combined with other Profiles to define the complete functionality of an OPC UA Server or Client.

18.1 Conformance Units

This chapter defines the corresponding Conformance Unit for OPC 40082-6.

Table 44 - Conformance Units for OPC 40082-6
Category Title Description
ServerOPC 40082-6 BasicSupport of GranulateDryingDeviceType and all mandatory child elements giving information on the dosing system and its status. There is at least one instance of the GranulateDryingDeviceType in the Machines Object.
ServerOPC 40082-6 MaintenanceSupport of MaintenanceInformationType and all mandatory child elements giving information on the maintenance activities on the mould.
ServerOPC 40082-6 UsersSupport of UserLoginType to enable automatic login of the machine user onto the mould controller.
ServerOPC 40082-6 DesiccantBedSupport of DessicantBedsType and at least one child element in at least one instance of DessicantBedType
ServerOPC 40082-6 DryingProtectionSupport of ActivateDryingProtection, DeactivateDryingProtection and DryingProtectionStatus
ServerOPC 40082-6 AllFeedersSupport of ActivateAllFeeders, DeactivateAllFeeders and AllFeedersStatus
ServerOPC 40082-6 MaterialFeederSupport of ActivateMaterialFeederDryer, DeactivateMaterialFeederDryer and MaterialFeederDryerStatus
ServerOPC 40082-6 MachineFeederSupport of ActivateMaterialFeederMachine, DeactivateMaterialFeederMachine and MaterialFeederMachineStatus
ServerOPC 40082-6 TemperatureControllerSupport of ActivateTemperatureController, DeactivateTemperatureController and TemperatureControllerStatus
ServerOPC 40082-6 AirFlowIntervalSupport of AirFlowMode, IntervalTimeOn and IntervalTimeOff
ServerOPC 40082-6 ResetDryingTimeSupport of ResetDryingTime and ResetDryingTimeResponseStatus
ServerOPC 40082-6 DesiccantBedControllerSupport of ActivateDesiccantBedController, DeactivateDesiccantBedController and DesiccantBedControllerStatus
ServerOPC 40082-6 MaterialIdentificationSupport of MaterialIdentification
ServerOPC 40082-6 BatchNumberSupport of BatchNumber
ServerOPC 40082-6 MaterialDryingTimeSupport of DryingTime
ServerOPC 40082-6 RemainingMaterialDryingTimeSupport of RemainingMaterialDryingTime
ServerOPC 40082-6 DisplayLanguageSupport of DisplayLanguage
ServerOPC 40082-6 IdentifyDeviceSupport of IdentifyDevice
ServerOPC 40082-6 ResetAllErrorsSupport of ResetAllErrors
ServerOPC 40082-6 ResetErrorByIdSupport of ResetErrorById
ServerOPC 40082-6 ResetEnergyMeasurementSupport of ResetEnergyMeasurement
ServerOPC 40082-6 MainFailureBehaviourSupport of MainFailureBehaviour
ServerOPC 40082-6 TotalEnergySupport of TotalEnergy
ServerOPC 40082-6 EnergyConsumptionResettableSupport of EnergyConsumptionResettable
ServerOPC 40082-6 MaintenanceInformationSupport of MaintenanceInformation
ServerOPC 40082-6 EnergyConsumptionLimitSupport of EnergyConsumptionLimit
ServerOPC 40082-6 DewPointSupport of DewPoint
ServerOPC 40082-6 AirFlowSupport of AirFlow
ServerOPC 40082-6 TemperatureOfDesiccantBedSupport of TemperatureOfDesiccantBed
ServerOPC 40082-6 TemperatureDesiccantBedOutSupport of TemperatureDesiccantBedOut
ServerOPC 40082-6 TemperatureBackToDesiccantBedSupport of TemperatureBackToDesiccantBed
ServerOPC 40082-6 ExpiredDryingTimeSupport of ExpiredDryingTime
ServerOPC 40082-6 TemperatureReductionSupport of TemperatureReduction
ServerOPC 40082-6 MaterialAvailableDryerSupport of MaterialAvailableDryer
ServerOPC 40082-6 MaterialAvailableMachineSupport of MaterialAvailableMachine
ServerOPC 40082-6 DustRemovalPulsesSupport of DustRemovalPulses
ServerOPC 40082-6 DryingLevelSupport of DryingLevel
ServerOPC 40082-6 AirFlowModeSupport of AirFlowMode
ServerOPC 40082-6 IntervalTimeOnSupport of IntervalTimeOn
ServerOPC 40082-6 IntervalTimeOffSupport of IntervalTimeOff
ServerOPC 40082-6 InitialFillingActiveSupport of InitialFillingActive
ServerOPC 40082-6 AirSourceSupport of AirSource
ServerOPC 40082-6 TotalAirConsumptionSupport of TotalAirConsumption
ServerOPC 40082-6 DryAirTemperatureSupport of DryAirTemperature
ServerOPC 40082-6 AmbientAirTemperatureSupport of AmbientAirTemperature
ServerOPC 40082-6 TopTemperatureSupport of TopTemperature
ServerOPC 40082-6 ConeTemperatureSupport of ConeTemperature
ServerOPC 40082-6 CylinderTemperatureSupport of CylinderTemperature
ServerOPC 40082-6 LooseningAidSupport of LooseningAid
ServerOPC 40082-6 MaintenanceInstructionsSupport of MaintenanceInstructions
ServerOPC 40082-6 RemainingIntervalSupport of RemainingInterval

18.2 Profiles

18.2.1 Profile list

The following tables specify the facets available for Servers that implement the OPC 40082-6 Information Model companion specification.

Table 45 lists all Profiles defined in this document and defines their URIs.

Table 45 - Profile URIs for OPC 40082-6
Profile URI
OPC 40082-6 Basic Server Profile http://opcfoundation.org/UA-Profile/PlasticsRubber/GDD/Server/Basic
OPC 40082-6 DesiccantBedDryer Server Facet http://opcfoundation.org/UA-Profile/PlasticsRubber/GDD/Server/DesiccantBed
OPC 40082-6 Full Server Facet http://opcfoundation.org/UA-Profile/PlasticsRubber/GDD/Server/Full

18.2.2 Server Facets

18.2.2.1 Overview

The following sections specify the Facets available for Servers that implement the OPC 40082-6 companion specification. Each section defines and describes a Facet or Profile.

18.2.2.2 OPC 40082-6 Basic Server Profile
Table 46 - OPC 40082-6 Basic Server Profile
Group Conformance Unit / Profile Title Mandatory / Optional
Profile0:Embedded Server 2017 (defined in OPC 10000-7)M
Profile0:ComplexType Server Facet (defined in OPC 10000-7)M
Profile0:Standard Event Subscription Server Facet (defined in OPC 10000-7)M
Profile0:Method Server Facet (defined in OPC 10000-7)M
Profile2:BaseDevice Server Facet (defined in OPC 10000-100)M
Profile3:Machinery Machine Identification Server FacetM
Profile3:Machinery State Server FacetM
Profile0:A & C Alarm Server FacetM
OPC 40082-6OPC 40082-6 BasicM
18.2.2.3 DesiccantBedDryer Server Facet
Table 47: OPC 40082-6 DesiccantBedDryer Server Facet
Group Conformance Unit / Profile Title Mandatory / Optional
OPC 40082-6OPC 40082-6 BasicM
OPC 40082-6OPC 40082-6 DesiccantBedM
18.2.2.4 Full Server Facet
Table 48: OPC 40082-6 Full Server Facet
Group Conformance Unit / Profile Title Mandatory / Optional
OPC 40082-6OPC 40082-6 BasicM
OPC 40082-6OPC 40082-6 MaintenanceO
OPC 40082-6OPC 40082-6 UsersO
OPC 40082-6OPC 40082-6 DryingProtectionO
OPC 40082-6OPC 40082-6 AllFeedersO
OPC 40082-6OPC 40082-6 MaterialFeederO
OPC 40082-6OPC 40082-6 MachineFeederO
OPC 40082-6OPC 40082-6 TemperatureControllerO
OPC 40082-6OPC 40082-6 AirFlowIntervalO
OPC 40082-6OPC 40082-6 ResetDryingTimeO
OPC 40082-6OPC 40082-6 DesiccantBedControllerO
OPC 40082-6OPC 40082-6 MaterialIdentificationO
OPC 40082-6OPC 40082-6 BatchNumberO
OPC 40082-6OPC 40082-6 MaterialDryingTimeO
OPC 40082-6OPC 40082-6 RemainingMaterialDryingTimeO
OPC 40082-6OPC 40082-6 DisplayLanguageO
OPC 40082-6OPC 40082-6 IdentifyDeviceO
OPC 40082-6OPC 40082-6 ResetAllErrorsO
OPC 40082-6OPC 40082-6 ResetErrorByIdO
OPC 40082-6OPC 40082-6 ResetEnergyMeasurementO
OPC 40082-6OPC 40082-6 MainFailureBehaviourO
OPC 40082-6OPC 40082-6 TotalEnergyO
OPC 40082-6OPC 40082-6 EnergyConsumptionResettableO
OPC 40082-6OPC 40082-6 MaintenanceInformationO
OPC 40082-6OPC 40082-6 EnergyConsumptionLimitO
OPC 40082-6OPC 40082-6 DewPointO
OPC 40082-6OPC 40082-6 AirFlowO
OPC 40082-6OPC 40082-6 TemperatureOfDesiccantBedO
OPC 40082-6OPC 40082-6 TemperatureDesiccantBedOutO
OPC 40082-6OPC 40082-6 TemperatureBackToDesiccantBedO
OPC 40082-6OPC 40082-6 ExpiredDryingTimeO
OPC 40082-6OPC 40082-6 TemperatureReductionO
OPC 40082-6OPC 40082-6 MaterialAvailableDryerO
OPC 40082-6OPC 40082-6 MaterialAvailableMachineO
OPC 40082-6OPC 40082-6 DustRemovalPulsesO
OPC 40082-6OPC 40082-6 DryingLevelO
OPC 40082-6OPC 40082-6 AirFlowModeO
OPC 40082-6OPC 40082-6 IntervalTimeOnO
OPC 40082-6OPC 40082-6 IntervalTimeOffO
OPC 40082-6OPC 40082-6 InitialFillingActiveO
OPC 40082-6OPC 40082-6 ResetDryingTimeO
OPC 40082-6OPC 40082-6 AirSourceO
OPC 40082-6OPC 40082-6 TotalAirConsumptionO
OPC 40082-6OPC 40082-6 DryAirTemperatureO
OPC 40082-6OPC 40082-6 AmbientAirTemperatureO
OPC 40082-6OPC 40082-6 TopTemperatureO
OPC 40082-6OPC 40082-6 ConeTemperatureO
OPC 40082-6OPC 40082-6 CylinderTemperatureO
OPC 40082-6OPC 40082-6 LooseningAidO
OPC 40082-6OPC 40082-6 MaintenanceInstructionsO
OPC 40082-6OPC 40082-6 RemainingIntervalO