30 Profiles and Conformance Units

This chapter defines the corresponding profiles and conformance units for the OPC UA Information Model for OPC 40082-5. Profiles are named groupings of conformance units. Facets are profiles that will be combined with other Profiles to define the complete functionality of an OPC UA Server or Client.

30.1 Conformance Units

This chapter defines the corresponding Conformance Unit for OPC 40082-5.

Table 45 - Conformance Units for OPC 40082-5
CategoryTitleDescription
ServerOPC 40082-5 BasicSupport of MouldDeviceType and all mandatory child elements giving information on the dosing system and its status. There is at least one instance of the MouldDeviceType in the Machines Object.
ServerOPC 40082-5 MaintenanceSupport of MaintenanceInformationType and all mandatory child elements giving information on the maintenance activities on the mould.
ServerOPC 40082-5 AlarmsThis Conformance Unit requires support of A & C Alarm Server Facet
ServerOPC 40082-5 UsersSupport of UserLoginType to enable automatic login of the machine user onto the mould controller.
ServerOPC 40082-5 TemperaturesSupport of TemperaturesType and MouldProcessValueType to monitor temperature process values of the mould.
ServerOPC 40082-5 TemperatureDifferencesSupport of TemperatureDifferencesType and MouldProcessValueType to monitor temperature difference process values of the mould.
ServerOPC 40082-5 PressuresSupport of PressuresType and MouldProcessValueType to monitor pressure process values of the mould.
ServerOPC 40082-5 PressureDifferencesSupport of PressureDifferencesType and MouldProcessValueType to monitor pressure difference process values of the mould.
ServerOPC 40082-5 FlowRatesSupport of FlowRatesType and MouldProcessValueType to monitor flow rate process values of the mould.
ServerOPC 40082-5 DistancesSupport of DistancesType and MouldProcessValueType to monitor distance process values of the mould.
ServerOPC 40082-5 ForcesSupport of ForcesType and MouldProcessValueType to monitor force process values of the mould.
ServerOPC 40082-5 AcousticValuesSupport of AcousticValuesType and MouldProcessValueType to monitor acoustic values of the mould.
ServerOPC 40082-5 DigitalInputsSupport of DigitalInputsType and DigitalValueType to monitor the digital inputs of the mould.
ServerOPC 40082-5 DigitalOutputsSupport of DigitalOutputsType and DigitalValueType to monitor the digital outputs of the mould.

30.2 Profiles

30.2.1 Profile list

The following tables specify the facets available for Servers that implement the OPC 40082-5 Information Model companion specification.

Table 46 lists all Profiles defined in this document and defines their URIs.

Table 46 - Profile URIs for OPC 40082-5
ProfileURI
OPC 40082-5 Basic Server Profilehttp://opcfoundation.org/UA-Profile/PlasticsRubber/Moulds/Server/Basic

30.2.2 Server Facets

30.2.2.1 Overview

The following sections specify the Facets available for Servers that implement the OPC 40082-5 companion specification. Each section defines and describes a Facet or Profile.

30.2.2.2 OPC 40082-5 Basic Server Profile
Table 47 - OPC 40082-5 Basic Server Profile
GroupConformance Unit / Profile TitleMandatory / Optional
Profile0:Embedded Server 2017 (defined in OPC 10000-7)M
Profile0:ComplexType Server Facet (defined in OPC 10000-7)M
Profile0:Standard Event Subscription Server Facet (defined in OPC 10000-7)M
Profile0:Method Server Facet (defined in OPC 10000-7)M
Profile2:BaseDevice Server Facet (defined in OPC 10000-100)M
OPC 40082-5OPC 40082-5 BasicM
OPC 40082-5OPC 40082-5 AlarmsO
OPC 40082-5OPC 40082-5 MaintenanceO
OPC 40082-5OPC 40082-5 UsersO
OPC 40082-5OPC 40082-5 TemperaturesO
OPC 40082-5OPC 40082-5 TemperatureDifferencesO
OPC 40082-5OPC 40082-5 PressuresO
OPC 40082-5OPC 40082-5 PressureDifferencesO
OPC 40082-5OPC 40082-5 FlowRatesO
OPC 40082-5OPC 40082-5 DistancesO
OPC 40082-5OPC 40082-5 ForcesO
OPC 40082-5OPC 40082-5 AcousticValuesO
OPC 40082-5OPC 40082-5 DigitalInputsO
OPC 40082-5OPC 40082-5 DigitalOutputsO