The following sections define the Facets and Profiles available for Servers that implement the OPC UA for Compressed Air Systems companion specification.
This Facet defines the elements for a Main Control System that provides prefabricated or pre-parameterized analyses on Compressed Air System or Airnet level. Although both Conformance Units are listed as optional, at least one shall be implemented to comply with this Facet.
Table 164 – CAS Base Analyses Server Facet
Group |
Conformance Unit / Profile Title |
M / O |
CAS |
CAS Analyses - Prefabricated |
O |
CAS |
CAS Analyses - Pre-parameterized |
O |
This Facet defines the elements for a Main Control System that provides parameterizable analyses on Compressed Air System or Airnet level and the possibility to store analysis reports in the AddressSpace.
Table 165 – CAS Advanced Analyses Server Facet
Group |
Conformance Unit / Profile Title |
M / O |
CAS |
CAS Analyses - Parameterizable |
M |
CAS |
CAS Analyses - OutputFile |
M |
This Facet defines the elements for a Main Control System that provides its OPC UA communication settings and the component class for Components.
Table 166 – CAS Base Configuration Server Facet
Group |
Conformance Unit / Profile Title |
M / O |
CAS |
CAS Configuration - Communication Settings |
M |
CAS |
CAS Configuration - ComponentClass |
M |
This Facet defines the elements for a Main Control System whose configuration can be stored as a file in the OPC UA AddressSpace.
Table 167 – CAS Advanced Configuration Server Facet
Group |
Conformance Unit / Profile Title |
M / O |
CAS |
CAS Configuration - Load |
M |
CAS |
CAS Configuration - Save |
M |
This Facet defines the elements for a Main Control System that provides a health state and statistics for CASParts.
Table 168 – CAS Base Maintenance Management Server Facet
Group |
Conformance Unit / Profile Title |
M / O |
CAS |
CAS Maintenance - HealthState |
M |
CAS |
CAS Maintenance - Statistics |
M |
This Facet defines the elements for a Main Control System that provides events and conditions.
Table 169 – CAS Advanced Maintenance Management Server Facet
Group |
Conformance Unit / Profile Title |
M / O |
CAS |
CAS Maintenance - MCS to Server |
M |
CAS |
CAS Events |
M |
This Facet defines the elements for a Main Control System that provides necessary Variables and their historization for energy management applications.
Table 170 – CAS Energy Management Server Facet
Group |
Conformance Unit / Profile Title |
M / O |
CAS |
CAS Energy Management - Electrical Quantities |
M |
CAS |
CAS Energy Management - Process Fluid Quantities |
M |
CAS |
CAS Energy Management - Runtime Quantities |
M |
CAS |
CAS Energy Management - Quantity Historization |
M |
This Facet defines the elements for a Main Control System that provides necessary Variables for operational applications.
Table 171 – CAS Operation Server Facet
Group |
Conformance Unit / Profile Title |
M / O |
CAS |
CAS Operation - IntegratedState |
M |
CAS |
CAS Operation - OperatingState |
M |
CAS |
CAS Operation - FluidType |
M |
CAS |
CAS Operation - ProcessFluidCircuit |
M |
CAS |
CAS Operation - ElectricalCircuit |
M |
CAS |
CAS Operation - CoolantCircuit |
M |
CAS |
CAS Operation - Statistics |
M |
This Profile defines the elements for a Main Control System that supports base functionality.
Table 172 – CAS Base Server Profile
Group |
Conformance Unit / Profile Title |
M / O |
Profile |
0:Address Space Notifier Server Facet http://opcfoundation.org/UA-Profile/Server/AddressSpaceNotifier |
M |
Profile |
0:Embedded 2017 UA Server Profile |
M |
Profile |
0:Data Access Server Facet |
M |
Profile |
0:ComplexType 2017 Server Facet |
M |
Profile |
4:Machine Identification Writable Server Facet http://opcfoundation.org/UA-Profile/Machinery/Server/MachineIdentificationWritable |
M |
CAS |
Base Analyses Server Facet |
O |
CAS |
Base Configuration Server Facethttp://opcfoundation.org/UA-Profile/CAS/Server/Configuration |
M |
CAS |
Base Maintenance Management Server Facethttp://opcfoundation.org/UA-Profile/CAS/Server/BaseMaintenance |
M |
CAS |
Operation Server Facethttp://opcfoundation.org/UA-Profile/CAS/Server/Operation |
M |
CAS |
CASPart Identification |
M |
CAS |
CASType Mandatory Nodes |
M |
CAS |
CASType Identification |
M |
CAS |
NE107 |
M |
This Profile defines the elements for a Main Control System that supports advanced functionality.
Table 173 – CAS Advanced Server Profile
Group |
Conformance Unit / Profile Title |
M / O |
Profile |
Base Server Profile |
M |
CAS |
Advanced Configuration Server Facet http://opcfoundation.org/UA-Profile/CAS/Server/AdvancedConfiguration |
M |
CAS |
Advanced Analyses Server Facet http://opcfoundation.org/UA-Profile/CAS/Server/AdvancedAnalyses |
M |
This Profile defines the elements for a Main Control System that supports the maintenance management use case.
Table 174 – CAS Maintenance Management Server Profile
Group |
Conformance Unit / Profile Title |
M / O |
Profile |
0:A & C Address Space Instance Server Facet http://opcfoundation.org/UA-Profile/Server/ACAddressSpaceInstance |
M |
Profile |
0:A & C Exclusive Alarming Server Facet http://opcfoundation.org/UA-Profile/Server/ACExclusiveAlarming |
M |
Profile |
0:Aggregate Subscription Server Facet http://opcfoundation.org/UA-Profile/Server/AggregateSubscription |
M |
Profile |
3:IA Statistical Data Server Profilehttp://opcfoundation.org/UA-Profile/IA/Server/StatisticalData |
M |
Profile |
Base Server Profile |
M |
CAS |
Advanced Maintenance Management Server Facethttp://opcfoundation.org/UA-Profile/CAS/Server/AdvancedMaintenance |
M |
CAS |
Maintenance - Server to MCS |
M |
CAS |
Maintenance - Sensor |
O |
This Profile defines the elements for a Main Control System that supports the energy management use case.
Table 175 – CAS Energy Management Server Profile
Group |
Conformance Unit / Profile Title |
M / O |
Profile |
Base Server Profile |
M |
CAS |
Energy Management Server Facet |
M |
This Profile defines the elements for a Main Control System that supports node manipulation during the runtime of the Server.
Table 176 – CAS Dynamic Server Profile
Group |
Conformance Unit / Profile Title |
M / O |
Profile |
0:Node Management Server Facet |
M |
Profile |
Base Server Profile |
M |
CAS |
Dynamic - Add/Remove |
M |
CAS |
Dynamic - Move |
M |
This Profile defines the elements for a Main Control System which supports all ConformanceUnits.
Table 177 – CAS Full Server Profile
Group |
Conformance Unit / Profile Title |
M / O |
Profile |
Base Server Profile |
M |
CAS |
Advanced Analyses Server Facet http://opcfoundation.org/UA-Profile/CAS/Server/AdvancedAnalyses |
M |
CAS |
Advanced Configuration Server Facet http://opcfoundation.org/UA-Profile/CAS/Server/AdvancedConfiguration |
M |
CAS |
Advanced Maintenance Management Server Facet http://opcfoundation.org/UA-Profile/CAS/Server/AdvancedMaintenance |
M |
CAS |
Energy Management Server Facet |
M |
CAS |
CAS Maintenance - Server to MCS |
M |
CAS |
CAS Maintenance - Sensor |
M |
CAS |
CAS Dynamic - Add/Remove |
M |
CAS |
CAS Dynamic - Move |
M |