6.2.3 ObjectType Description

6.2.3.1 Object RuntimeParameters

This FunctionalGroup is inherited from the AutoIdDeviceType and described in 6.1. Predefined runtime parameters for for this FunctionalGroup are defined in Table 10 and described below.

Parameter TemplateName is the activate template which defines a specific identification task. The templates have to be defined during configuration.

Parameter MatchCode defines the target value for 2D and OCR decoding.

6.2.3.2 Object Images

For quality and testing purposes, the actual image taken by the OCR reader can be accessed with this object. E.g. the picture might be checked by engineers if the OCR decoding does not deliver the expected results.

The Images Object when available shall contain the list of FileType Objects (see Table 10) with the images taken by the OCR reader.

The MIME type of an image is provided through the MimeType Property of the FileType.

6.2.3.3 Method Scan

This method starts the scan process of the OCR reader device syncronous and returns the scan results. It overwrites the Scan method of the AutoIdDeviceType defined in 6.1.3.4.

Signature

	Scan (
		[in]	ScanSettings				Settings
		[out]	OcrScanResult []				Results
		[out]	AutoIdOperationStatusEnumeration	Status
		);
	
Argument Description
SettingsConfiguration settings for the scan execution. The ScanSettings DataType is defined in 9.3.7.
Results Results of the scan execution. The OcrScanResult DataType is defined in 9.3.9.
Status

Returns the status of the scan operation.

The AutoIdOperationStatusEnumeration DataType is defined in 9.2.1.

Method Result Codes

ResultCode Description
Bad_InvalidStateThere is already a scan active
Bad_InvalidArgumentThe scan setting contained an invalid value like infinite duration.
Other OPC UA status codes defined for the Call Service in OPC 10000-4.