6.2.3.3 RequestSPDUDataType
Table 18 shows the definition of the RequestSPDUDataType. The Prefix “In” is interpreted from the SafetyProvider’s point of view and is used in a consistent manner to the parameters of the Method ReadSafetyData (see 6.2.2.3).
| Name | Type | Description |
|---|---|---|
| RequestSPDUDataType | structure | |
| InSafetyConsumerID | UInt32 | See corresponding Method argument in Table 7. |
| InMonitoringNumber | UInt32 | See corresponding Method argument in Table 7. |
| InFlags | InFlagsType | See corresponding Method argument in Table 7. |
The representation in the AddressSpace of the RequestSPDUDataType is defined in Table 19.
| Attributes | Value | ||||
|---|---|---|---|---|---|
| BrowseName | RequestSPDUDataType | ||||
| IsAbstract | False | ||||
| References | NodeClass | BrowseName | DataType | TypeDefinition | ModellingRule |
| Subtype of Structure defined in OPC 10000-3. | |||||
| Conformance units | |||||
| SafetyPDUs | |||||