OPC UA for Mining - External Standards – Part 1: IREDES
6.5 DispFlag
The enumeration DispFlag is used to determine when to display messages to the machine operator. It is formally defined in Table 12.
Table 12 – DispFlag Items
Name
Value
Description
MachStart
0
To be displayed when the machine is started. Machine start is defined as switching on the main power supply or power generation.
FileLoad
1
To be displayed as soon as the file is loaded (activated) in the machine’s automation system (applicable especially to plan files originating from the mine!).
Its representation in the AddressSpace is defined in Table 13.
Table 13 – DispFlag Definition
Attribute
Value
BrowseName
DispFlag
IsAbstract
False
References
NodeClass
BrowseName
DataType
TypeDefinition
Other