7.4.2.1 OPENSCS Base Server Profile

Table 74 defines a Profile for the minimum functionality necessary for a component that conforms to the functionality of an OPENSCS server using the OPC UA Client/Server Interface.

Table 74 – OPENSCS Base Server Profile Definition
Server Facets and Profiles Defined In Optional / Mandatory
Standard 2017 UA Server Profile . OPC 10000-7 M
Base Server Behaviour Facet . OPC 10000-7 M
Sessionless Server Facet . OPC 10000-7 M
Documentation Server Facet . OPC 10000-7 M
Standard DataChange Subscription 2017 Server Facet . OPC 10000-7 M
Data Access Server Facet . OPC 10000-7 M
Auditing Server Facet . OPC 10000-7 M
Address Space Notifier Server Facet . OPC 10000-7 M
Security Facets
Security User Access Control Base . OPC 10000-7 M
Security Time Synchronization . OPC 10000-7 M
Best Practice – Audit Events . OPC 10000-7 M
Best Practice – Random Numbers . OPC 10000-7 M
Best Practice – Timeouts . OPC 10000-7 M
Best Practice – Administrative Access . OPC 10000-7 M
Best Practice – Strict Message Handling . OPC 10000-7 M
SecurityPolicy [A] - Aes128-Sha256-RsaOaep . OPC 10000-7 M
SecurityPolicy [B] – Basic256Sha256 . OPC 10000-7 M
User Token – JWT Server Facet . OPC 10000-7 M
User Role Management Server Facet . OPC 10000-7 M
Global Certificate Management Server Facet . OPC 10000-7 M
OPENSCS Security Server Facet 7.4.1.1 M
Authorization Service Server Facet . OPC 10000-7 M