10.1 RunInfoDataType

This structure contains the information related to a job run. The structure is defined in Table 23.

Table 23 – RunInfoDataType Structure
Name Type Description Optional
RunInfoDataTypestructureSubtype of 0:Structure defined in OPC 10000-5

CurrentLayer

0:UInt32Counter that increases after each completed layer of the job run. This counter does not give any indication about the part quality.True

Identifier

0:StringIdentifier of the job run. This identifier is used to ensure an assignment of parts and job run(s). For this reason, the identifier shall be unique.False

State

9:ISA95StateDataTypeState information on job run level. This state works additionally to the overall job status.False

RemainingTime

0:DurationDescribes the remaining process time in seconds.True

Its representation in the AddressSpace is defined in Table 24.

Table 24 – RunInfoDataType Definiton
Attribute Value
BrowseNameRunInfoDataType
IsAbstractFalse
References Node Class BrowseName DataType TypeDefinition Other
Subtype of the 0:Structure defined in OPC 10000-5
Conformance Units
AdditiveManufacturing Job Management - Run Information