OPC-40223 – OPC UA for Pumps and Vacuum Pumps3.2.1 PumpClassPumpClass Specific type of a Pump and value of the PumpClass Variable of an instance of the FunctionalGroup Design of a Pump . EXAMPLE 1 The pump ... PumpClass positive displacement pump. EXAMPLE 2 The pump P2 is of the PumpClass turbo vacuum pump
-
OPC-40223 – OPC UA for Pumps and Vacuum Pumps3.2.2 FunctionalGroupentry: In this specification, FunctionalGroup usually refers to an instance of a Pump specific ObjectType like OperationalGroupType, ActuationType, or DesignType. EXAMPLE 1 The pump P1 has the FunctionalGroups Identification, Design
-
OPC-40223 – OPC UA for Pumps and Vacuum Pumps3.2.4 PortPort Connection point to a Pump used for fluids or auxiliary devices. Note 1 to entry: Ports are described in chapter 6.2 . EXAMPLE 1 The pump P1 has its process ... fluid inlet connected at the Port InletConnectionPort. EXAMPLE 2 The pump P1 has its drive connected at the Port DrivePort
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsIdentification The use case Device Identification forms the basis for the operation of a Pump and the operators plant asset management, e.g. Documentation Management, Energy Management and Maintenance Management ... this purpose, the Pump shall provide properties for asset identification. In addition to nameplate information of the Pump , the operator / integrator requires properties to describe its functional role and installation
-
OPC-40223 – OPC UA for Pumps and Vacuum Pumps5.2 ConfigurationConfiguration This use case describes the pre-configuration and commissioning of Pump based on standardized manufacturer and operator information. For this purpose, general characteristics about the pump type shall ... operation shall be specified by the operator. Additionally, manufacturer and operator information of a Pump shall be compared
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsMaintenance Management For the integration of Pump in an operator's maintenance management application, the Pump should provide properties for general maintenance and the three strategies breakdown maintenance, preventive maintenance ... condition based maintenance. To support asset monitoring, the Pump collects and analyzes operational and historical data (e.g. current values, deviations, performance, wear). Since plant operators require a generalized health status
-
OPC-40223 – OPC UA for Pumps and Vacuum Pumps5.4 OperationOperation This use case specifies all properties that characterize the operation of a Pump (e.g. current measurement and control values). It is based on measurements, events, and further information from ... Pump operation. These can be collected and analyzed by the manufacturer or operator. Based on this analysis, Pumps can be reconfigured or updated during operation. In addition, new services
-
OPC-40223 – OPC UA for Pumps and Vacuum Pumpsshell and its submodels were modeled to describe the whole life cycle of a Pump . The organization Plattform Industrie 4.0 published the specification Details [2] of the Asset Administration Shell ... submodels are modeled as subtypes of the 2:FunctionalGroupType of OPC 10000-100 . The pump, i.e. the asset administration shell, is modeled as a subtype of the 2:TopologyElementType
-
OPC-40223 – OPC UA for Pumps and Vacuum Pumps6.2.1 PortsPorts A Pump has several Ports . While most Pumps have inlet and outlet Ports , the number of other Ports may vary. For this reason, the concept of Ports is introduced ... Ports can be used to connect other components or systems to the Pump . In this specification, the input and output Ports , as well as the drive Port for the connection
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsExtending FunctionalGroups The manufacturer or system integrator of a Pump may wish to add Variables , Objects , or Methods which are not yet defined by this specification. In such a case
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsPumpType ObjectType DefinitionThe PumpType is the representation of a Pump and organizes its properties in FunctionalGroups . It is illustrated in Figure 9 and formally defined in Table 9 . Figure ... optional FunctionalGroup 2:Configuration provides collections of Nodes for manufacturer data about the Pump and user data about the Pump's process environment, such as maximum operating temperature and minimum
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsIPumpVendorNameplateType ObjectType Definition The IPumpVendorNameplateType provides the capabilities to globally uniquely identify a Pump . It is a subtype of the 3:IMachineVendorNameplateType and extends it by Pump specific Objects
-
OPC-40223 – OPC UA for Pumps and Vacuum Pumpsglobally unique identification, vendor defined information, and user-specific information of a Pump . It is illustrated in Figure 10 and formally defined in Table 15 . Figure 10 - Illustration of PumpIdentificationType ... ModellingRule is changed to Mandatory and the Value Attribute is set to "Pump". The InstanceDeclarations of the PumpIdentificationType have additional Attributes defined in Table 16 . Table 16 - PumpIdentificationType
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsSupervisionType ObjectType DefinitionThe SupervisionType provides collections of Variables used for Pump monitoring. It is illustrated in Figure 12 and formally defined in Table 29 . Figure 12 - Illustration of SupervisionType ... device mechanics. SupervisionProcessFluid Supervision process fluid specifies information for monitoring the fluid of a pump. SupervisionPumpOperation Supervision pump operation specifies information for monitoring the pump operation. SupervisionSoftware Supervision software specifies
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsSupervisionMechanicsType ObjectType Definition The SupervisionMechanicsType provides Variables used for monitoring the Pump mechanics. It is illustrated in Figure 13 and formally defined in Table 31 . For the generation of events
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsSupervisionHardwareType ObjectType Definition The SupervisionHardwareType provides Variables used for monitoring the Pump hardware. It is formally defined in Table 33 . For the generation of events, the SupervisionHardwareType has references
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsSupervisionSoftwareType ObjectType Definition The SupervisionSoftwareType provides Variables used for monitoring the Pump software. It is formally defined in Table 35 . For the generation of events, the SupervisionSoftwareType has references
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsSupervisionProcessFluidType ObjectType Definition The SupervisionProcessFluidType provides Variables used for monitoring the Pump process fluid. It is formally defined in Table 37 . For the generation of events, the SupervisionProcessFluidType has references ... This attribute indicates a closed valve operation. Cavitation This attribute indicates cavitation of the pump liquid. Condensation This attribute indicates abnormal condensation in flow medium. Dry This attribute indicates
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsSupervisionPumpOperationType ObjectType DefinitionThe SupervisionPumpOperationType provides Variables used for monitoring the Pump operation. It is formally defined in Table 39 . For the generation of events, the SupervisionPumpOperationType has references ... overheating of the coolant liquid. Deceleration This attribute indicates a deceleration of a pump. DirtyImpeller This attribute indicates a dirty impeller. DriveOverheat This attribute indicates an overheating of a drive
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsSupervisionAuxiliaryDeviceType ObjectType DefinitionThe SupervisionAuxiliaryDeviceType provides Variables used for monitoring the Pump auxiliary devices. It is formally defined in Table 41 . For the generation of events, the SupervisionAuxiliaryDeviceType has references
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsSupervisionElectronicsType ObjectType DefinitionThe SupervisionElectronicsType provides Variables used for monitoring the Pump electronics. It is formally defined in Table 43 . For the generation of events, the SupervisionElectronicsType has references
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsConfigurationGroupType ObjectType DefinitionThe ConfigurationGroupType provides FunctionalGroups for static manufacturer data about the Pump and user data about the Pump's process environment. General information on this use case ... Attribute values for child Nodes BrowsePath Description Attribute Design Static design properties for a pump. Implementation Static implementation properties for a pump. SystemRequirements Static system requirement properties for a pump
-
OPC-40223 – OPC UA for Pumps and Vacuum Pumpsprovides static Variables for design properties, describing the limitations and working conditions of a Pump and is formally defined in Table 47 . Table 47 - DesignType Definition Attribute Value BrowseName DesignType ... metre per second BasePressure Pressure obtained in the test dome after conditioning the vacuum pump and the test dome BasePressure 0:EngineeringUnits NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsDefinitionThe SystemRequirementsType provides static Variables for parameters of the process in which the Pump is to be used and is formally defined in Table 49 . Table 49 - SystemRequirementsType Definition ... Ratio of the backing pressure, p3, to the inlet pressure, p1, of the vacuum pump without throughput ExplosionZone Categories of explosion zones for devices according to 2014/34/EU (ATEX). Fieldbus Selected
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsImplementationType ObjectType DefinitionThe ImplementationType provides static Variables for preconfiguring a Pump for the process in which the Pump is to be used and is formally defined in Table ... absolute pressure of the atmosphere measured at the place of installation (2.1.1.3) of the pump AtmosphericPressure 0:EngineeringUnits NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal Density Volumetric
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsOperationalGroupType provides FunctionalGroups that collect Nodes for process data that is used during normal Pump operation, such as measurements, signals, and actuation. It is illustrated in Figure 14 and formally ... child Nodes BrowsePath Description Attribute BypassActuation Actuation parameters for a bypass valve of a pump. Control Control parameters for a pump. Measurements Measurements at a pump. MultiPump Properties for multi
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsControlType ObjectType Definition The ControlType provides Variables for precise control of a Pump according to DIN IEC 60050-351 and is formally defined in Table 55 . Table 55 - ControlType Definition
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsPumpActuationType ObjectType DefinitionThe PumpActuationType extends its supertype by Pump specific Objects and Variables for discrete outputs according to VDMA 24223. It is illustrated in Figure 16 and formally defined ... Nodes BrowsePath Description Attribute ActualControlMode This property describes the actual control mode of the pump. ActualOperationMode This property describes the actual operation mode of the pump. CleanValveRequest This element offers
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsObjectType Definition The abstract DiscreteObjectType provides Variables for discrete inputs and outputs of a Pump . It is illustrated in Figure 17 and formally defined in Table 61 . Figure 17 - Illustration
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsSignalsType ObjectType DefinitionThe SignalsType provides Objects to provide feedback on the current Pump state and is formally defined in Table 69 . Table 69 - SignalsType Definition Attribute Value BrowseName SignalsType ... child Nodes BrowsePath Description Attribute Acceleration This element serves a feedback that the pump rotation accelerates. CleanValveOpen This element serves a feedback about the open state of the cleaning valve
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsObjectType DefinitionThe MeasurementsType provides Objects and Variables used for measurements performed at a Pump . It is illustrated in Figure 18 and formally defined in Table 73 . For the generation ... OptionalPlaceholder Object Vibration is used for multiple vibration measurements at a Pump . Table 72 - MeasurementsType Additional Subcomponents Source Path References NodeClass BrowseName DataType TypeDefinition Other AmbientHumidity 0:HasProperty Variable KindOfQuantity
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsVibrationMeasurementType ObjectType DefinitionThe VibrationMeasurementType provides Variables for Pump vibration measurements according to IEC61987 and is formally defined in Table 74 . Table 74 - VibrationMeasurementType Definition Attribute Value BrowseName VibrationMeasurementType IsAbstract
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsMultiPumpType ObjectType Definition The MultiPumpType provides Variables for Pump operation in a system with several Pumps and is formally defined in Table 76 . Table 76 - MultiPumpType Definition Attribute Value BrowseName ... DistributionType This property describes the share of operation time of different pumps of the pump system in addition operation mode. ExchangeMode This property specifies the exchange mode of the pump
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsDrivePortType ObjectType DefinitionThe DrivePortType extends its supertype by FunctionalGroups for Pump drive specific Objects and Variables and is formally defined in Table 82 . Table 82 - DrivePortType Definition Attribute Value
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsInletConnectionPortType ObjectType Definition The InletConnectionPortType extends its supertype by FunctionalGroups for Pump inlet specific Objects and Variables and is formally defined in Table 84 . Table 84 - InletConnectionPortType Definition Attribute Value
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsOutletConnectionPortType ObjectType Definition The OutletConnectionPortType extends its supertype by FunctionalGroups for Pump outlet specific Objects and Variables and is formally defined in Table 86 . Table 86 - OutletConnectionPortType Definition Attribute Value
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsConnectionDesignType ObjectType Definition The abstract ConnectionDesignType provides static Variables for Pump inlet and outlet connection design properties. It is illustrated in Figure 20 and formally defined in Table 88 . Figure
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsInletConnectionDesignType ObjectType Definition The InletConnectionDesignType extends its supertype by Pump inlet connection specific Variables and is formally defined in Table 90 . Table 90 - InletConnectionDesignType Definition Attribute Value BrowseName InletConnectionDesignType IsAbstract ... defined in the instruction manual or in a specific standard for the particular vacuum pump. CriticalBackingPressure 0:EngineeringUnits NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal InletAreaOfThePump Free
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsOutletConnectionDesignType ObjectType Definition The OutletConnectionDesignType extends its supertype by Pump outlet connection specific Variables and is formally defined in Table 92 . Table 92 - OutletConnectionDesignType Definition Attribute Value BrowseName OutletConnectionDesignType IsAbstract ... BrowsePath Value Attribute Description Attribute MaximumAllowableOutletPressure Highest value of outlet pressure at which the pump or component is capable of functioning on the basis of the materials used. MaximumAllowableOutletPressure
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsDriveDesignType ObjectType Definition The DriveDesignType provides static Variables for Pump drive design properties and is formally defined in Table 94 . Table 94 - DriveDesignType Definition Attribute Value BrowseName DriveDesignType IsAbstract False ... Description: hertz MotorEfficiency Proportion of the motor power input P_mot delivered as pump power input P_mot, u. MotorEfficiency 0:EngineeringUnits NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName: % Description
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsInletConnectionSystemRequirementsType ObjectType Definition The InletConnectionSystemRequirementsType provides static Variables for Pump inlet connection specific parameters of the process in which the Pump is to be used and is formally defined ... child Nodes BrowsePath Value Attribute Description Attribute InletPressure Pressure at the inlet of the pump, measured at a defined location in the test dome. InletPressure 0:EngineeringUnits NamespaceUri: http://www.opcfoundation.org
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsOutletConnectionSystemRequirementsType ObjectType Definition The OutletConnectionSystemRequirementsType provides static Variables for Pump outlet connection specific parameters of the process in which the Pump is to be used and is formally defined ... Nodes BrowsePath Value Attribute Description Attribute BackingPressure Pressure at the outlet of a vacuum pump. BackingPressure 0:EngineeringUnits NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5259596 DisplayName: Pa Description: pascal
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsConnectionImplementationType ObjectType Definition The abstract ConnectionImplementationType provides static Variables for preconfiguring a Pump connection for the process in which the Pump is to be used. It is illustrated in Figure
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsInletConnectionImplementationType ObjectType Definition The InletConnectionImplementationType extends its supertype by Pump inlet connection specific Variables and is formally defined in Table 102 . Table 102 - InletConnectionImplementationType Definition Attribute Value BrowseName InletConnectionImplementationType IsAbstract ... Attribute Description Attribute HeightOfTheInletConnection Height of the center of the inlet connection of the pump HeightOfTheInletConnection 0:EngineeringUnits NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre MeanRatedVelocityAtInlet Rated
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsOutletConnectionImplementationType ObjectType Definition The OutletConnectionImplementationType extends its supertype by Pump inlet connection specific Variables and is formally defined in Table 104 . Table 104 - OutletConnectionImplementationType Definition Attribute Value BrowseName OutletConnectionImplementationType IsAbstract ... Attribute Description Attribute HeightOfTheOutletConnection Height of the center of the outlet connection of the pump. HeightOfTheOutletConnection 0:EngineeringUnits NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 5067858 DisplayName: m Description: metre MeanRatedVelocityAtOutlet Rated
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsDriveMeasurementsType ObjectType Definition The DriveMeasurementsType provides Variables used for measurements performed at a Pump drive and is formally defined in Table 106 . For the generation of events, the DriveMeasurementsType ... surface S MotorEfficiency Determined proportion of the motor power input P_mot delivered as pump power input P_mot, u MotorEfficiency 0:EngineeringUnits NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 20529 DisplayName
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsInletConnectionMeasurementsType ObjectType Definition The InletConnectionMeasurementsType provides Variables used for measurements performed at a Pump inlet connection and is formally defined in Table 109 . For the generation of events, the InletConnectionMeasurementsType ... Value Attribute Description Attribute InletTemperatureOfThePump Measured temperature acting at the inlet area of the pump. InletTemperatureOfThePump 0:EngineeringUnits NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact UnitId: 4932940 DisplayName: K Description: kelvin InletTemperatureOfThePump KindOfQuantity
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsOutletConnectionMeasurementsType ObjectType Definition The OutletConnectionMeasurementsType provides Variables used for measurements performed at a Pump outlet connection and is formally defined in Table 112 . For the generation of events, the OutletConnectionMeasurementsType ... child Nodes BrowsePath Value Attribute Description Attribute MeanVelocityAtOutlet Measured rate of flow at pump outlet connection divided by the outlet area of the pump. MeanVelocityAtOutlet 0:EngineeringUnits NamespaceUri: http://www.opcfoundation.org
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsOfferedControlModesOptionSet defines flags for offered control modes supported by the manufacturer of a Pump in Table 122 . The Values and the associated Descriptions are based on the standard VDMA
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsOfferedFieldbusesOptionSet The OfferedFieldbusesOptionSet defines flags for fieldbuses supported by the manufacturer of a Pump in Table 124 . Table 124 - OfferedFieldbusesOptionSet Values Value Bit No. Description Other 0 Additional fieldbuses listed
-
OPC-40223 – OPC UA for Pumps and Vacuum Pumps8.7 ControlModeEnumControlModeEnum The enumeration ControlModeEnum defines possible Pump control modes in Table 126 . Table 126 - ControlModeEnum Items Name Value Description ConstantPressureControl 0 Constant pressure control mode ConstantTemperatureControl 1 Constant temperature control
-
OPC-40223 – OPC UA for Pumps and Vacuum Pumps8.8 PumpClassEnumPumpClassEnum The enumeration PumpClassEnum defines possible Pump PumpClasss in Table 128 . Table 128 - PumpClassEnum Items Name Value Description RotodynamicPump 0 Rotodynamic pump PositiveDisplacementPump 1 Positive displacement pump ProcessVacuumPump 2 Process ... vacuum pump TurboVacuumPump 3 Turbo vacuum pump VacuumPump 4 Vacuum pump LiquidPump 5 Liquid pump Pump 6 Pump The PumpClassEnum representation in the AddressSpace is formally defined in Table
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsDistributionTypeEnum The enumeration DistributionTypeEnum defines possible Pump distributions in Table 130 . The Values and the associated Descriptions are based on the standard VDMA 24223. Table 130 - DistributionTypeEnum Items Name Value
-
OPC-40223 – OPC UA for Pumps and Vacuum Pumps8.10 ExchangeModeEnumExchangeModeEnum The enumeration ExchangeModeEnum defines possible Pump exchange modes in Table 132 . The Values and the associated Descriptions are based on the standard VDMA 24223. Table 132 - ExchangeModeEnum Items Name ... Value Description ManufacturerSpecific 0 Manufacturer specific pump exchange mode ExchangeDisabled 1 Pump exchange disabled OperatorSpecific 2 Operator specific pump exchange mode The ExchangeModeEnum representation in the AddressSpace is formally defined
-
OPC-40223 – OPC UA for Pumps and Vacuum Pumps8.11 FieldbusEnumFieldbusEnum The enumeration FieldbusEnum defines possible Pump fieldbuses in Table 134 . Table 134 - FieldbusEnum Items Name Value Description Other 0 Fieldbus is not specified in this enumeration ARCNET 1 ARCNET
-
OPC-40223 – OPC UA for Pumps and Vacuum Pumps8.12 MaintenanceLevelEnumMaintenanceLevelEnum The enumeration MaintenanceLevelEnum defines possible Pump maintenance levels in Table 136 . The Values and the associated Descriptions are based on the standard DIN EN 13306. Table 136 - MaintenanceLevelEnum Items
-
OPC-40223 – OPC UA for Pumps and Vacuum PumpsMultiPumpOperationModeEnum The enumeration MultiPumpOperationModeEnum defines possible multi Pump operation modes in Table 138 . The Values and the associated Descriptions are based on the standard VDMA 24223. Table 138 - MultiPumpOperationModeEnum Items ... Name Value Description Standalone 0 Standalone mode RedundancyOperation 1 pump fulfils the process function of another pump AdditionOperation 2 supplementary fulfilling of the process function MixedRedundancy 3 Redundancy and addition
-
OPC-40223 – OPC UA for Pumps and Vacuum Pumps8.14 OperatingModeEnumOperatingModeEnum The enumeration OperatingModeEnum Pump operating modes in Table 140 . Table 140 - OperatingModeEnum Items Name Value Description SingleOperation 0 Single operating mode SeriesOperation 1 Series operating mode ParallelOperation 2 Parallel
-
OPC-40223 – OPC UA for Pumps and Vacuum Pumps8.15 OperationModeEnumOperationModeEnum The enumeration OperationModeEnum defines possible Pump operation modes in Table 142 . The Values and the associated Descriptions are based on the standard VDMA 24223. Table 142 - OperationModeEnum Items Name
-
OPC-40223 – OPC UA for Pumps and Vacuum Pumps8.17 PumpKickModeEnumPumpKickModeEnum The enumeration PumpKickModeEnum defines possible Pump kick modes in Table 146 . The Values and the associated Descriptions are based on the standard VDMA 24223. Table 146 - PumpKickModeEnum Items Name ... Value Description ManufacturerSpecific 0 Manufacturer specific pump kick mode Disabled 1 Pump kick mode disabled OperatorSpecific 2 Operator specific pump kick mode The PumpKickModeEnum representation in the AddressSpace is formally
-
OPC-40223 – OPC UA for Pumps and Vacuum Pumps8.18 PumpRoleEnumPumpRoleEnum The enumeration PumpRoleEnum defines possible Pump roles in Table 148 . The Values and the associated Descriptions are based on the standard VDMA 24223. Table 148 - PumpRoleEnum Items Name Value
-
OPC-40223 – OPC UA for Pumps and Vacuum Pumps8.19 StateOfTheItemEnumStateOfTheItemEnum The enumeration StateOfTheItemEnum defines possible Pump states in Table 150 . The Values and the associated Descriptions are based on the standard DIN EN 13306. Table 150 - StateOfTheItemEnum Items Name
-
OPC-40223 – OPC UA for Pumps and Vacuum Pumps9.2.2.2 Pump Base Server ProfilePump Base Server Profile This Profile defines the elements for a Pump Server which supports basic functionality like the configuration of the Pump , perform various analyses, and provide machine identification ... Table 154 - Pump Base Server Profile Group Conformance Unit / Profile Title M / O Profile 0:Embedded 2017 UA Server Profile http://opcfoundation.org/UA-Profile/Server/EmbeddedUA2017 M Profile 0:Data Access Server Facet