5.2 Configuration
The TTD should be able to provide information about its hard-/software configuration.
5.2.1 Available test procedures on the TTD
A production or quality manager wants to know the available test procedures that can be performed on a TTD in order to schedule upcoming test-jobs. The TTD delivers a list of test procedures. Each test procedure is characterized by the following properties:
TestProcedureId
Description
ProcedureReferences
IsProcedureLicensed
5.2.2 Available exchangeable parts
A production or quality manager wants to know the available exchangeable parts of a TTD in order to schedule upcoming test-jobs or plan maintenance. Exchangeable parts for example are load cells, clamp types, jaw faces and others.
For the identification of an exchangeable part, the following information is provided:
Name of the exchangeable part
PartId of the exchangeable part (this can be an Id or a serial number of the part)
LastCalibrationDate of the device
Additional to the information about the exchangeable part itself the following flags are provided:
Mounted indicates if the exchangeable part is currently mounted in the device or not.
Traceable indicates if the part is traceable or not. A part is traceable if it has a part id or serial number.
MachineReadable indicates if the PartId is machine readable
5.2.3 Installed / AvailableTester Modules
A production or quality manager would like to know which tester modules are installed in a testing device for the purposes of test planning on a dashboard, control station or mobile device. The tester modules can be hardware modules as well as software-modules. Examples are feeding devices, or yarn-break-detectors.
The following information about a tester module are exposed:
ModuleName the name of the module.
ModuleType the type of the module. E.g. hardware or software.
IsInstalled indicates if the module is installed on the TTD or not.
Version the version of the soft-/hardware module.