9.6 OperatingMode

Description:Actual operating mode of the TCD.
Table 6 – OperatingModeEnumeration Values
Name Value Description
OTHER0Operating mode of the TCD is unknown
READY_TO_OPERATE1TCD is ready to operate (heating, pump and cooling are switched off)
NORMAL_OPERATION2TCD is running in normal operating mode
LEAK_STOPPER3TCD is running in leak stopper operating mode
MOULD_EVACUATION4TCD is carrying out a mould evacuation process
PRESSURE_RELIEF5TCD is carrying out a pressure relief process
COOLING6TCD is cooling down to StandbyTemperature and switch off
SAFETY_COOLING7TCD is cooling down to SwitchingOffTemperature and switch off
ECO8TCD is running in Eco operating mode (energy is saved via the reduced pump speed)
BOOST9TCD is running in Boost operating mode (pump runs at maximum possible speed)