OPC UA interfaces for plastics and rubber machinery – Peripheral devices – Part 1: Temperature control devices
10.22 MouldEvacuationType
MouldEvacuationType is an optional component of DeviceZoneType and includes parameters and nodes for mould evacuation.
Table 14 – MouldEvacuationType Definition
Attribute
Value
BrowseName
MouldEvacuationType
IsAbstract
False
References
Node Class
BrowseName
DataType
TypeDefinition
Other
Subtype of 0:BaseObjectType defined in OPC UA Part 5
0:HasComponent
Method
On
M
0:HasComponent
Method
Off
M
0:HasComponent
Variable
TemperatureLimit
0:Double
0:AnalogItemType
O, RW
0:HasComponent
Variable
Time
0:Double
0:AnalogItemType
O, RW
0:HasComponent
Variable
Sink
0:UInt16
0:MultiStateValueDiscreteType
O, RW
0:HasComponent
Variable
Mode
0:UInt16
0:MultiStateValueDiscreteType
O, RW
10.22.1 On
Description:
Activate evacuation mode
Signature
On ();
10.22.2 Off
Description:
Deactivate evacuation mode
Signature
Off ();
10.22.3 TemperatureLimit
Description:
Temperature Limitation of the mould evacuation. TCD is cooled to this temperature first if necessary.
Unit:
°C or °F
Example:
70
10.22.4 Time
Description:
Duration of the mould evacuation.
Unit:
s
Example:
45
10.22.5 Sink
Description:
Defines where the medium is to be emptied
The TypeDefinition is MultiStateValueDiscreteType,so the PropertiesEnumValues and ValueAsText must be filled with the supported values out of Table 15.
Table 15 – Values for Sink
EnumValue
ValueAsText
Description
0
DRAIN
medium is passed into the cooling or system water outlet
1
TANK
medium is conducted in a separate outlet
10.22.6 Mode
Description:
Defines how the medium is to be emptied.
The TypeDefinition is MultiStateValueDiscreteType,so the PropertiesEnumValues and ValueAsText must be filled with the supported values out of Table 16.