10.22 MouldEvacuationType

MouldEvacuationType is an optional component of DeviceZoneType and includes parameters and nodes for mould evacuation.

Table 14 – MouldEvacuationType Definition
Attribute Value
BrowseNameMouldEvacuationType
IsAbstractFalse
References Node Class BrowseName DataType TypeDefinition Other
Subtype of 0:BaseObjectType defined in OPC UA Part 5
0:HasComponentMethodOnM
0:HasComponentMethodOffM
0:HasComponentVariableTemperatureLimit0:Double0:AnalogItemTypeO, RW
0:HasComponentVariableTime0:Double0:AnalogItemTypeO, RW
0:HasComponentVariableSink0:UInt160:MultiStateValueDiscreteTypeO, RW
0:HasComponentVariableMode0:UInt160:MultiStateValueDiscreteTypeO, RW

10.22.1 On

Description:Activate evacuation mode

Signature

	On ();

10.22.2 Off

Description:Deactivate evacuation mode

Signature

	Off ();

10.22.3 TemperatureLimit

Description:Temperature Limitation of the mould evacuation. TCD is cooled to this temperature first if necessary.
Unit: °C or °F
Example:70

10.22.4 Time

Description:Duration of the mould evacuation.
Unit: s
Example:45

10.22.5 Sink

Description:Defines where the medium is to be emptied

The TypeDefinition is MultiStateValueDiscreteType, so the Properties EnumValues and ValueAsText must be filled with the supported values out of Table 15.

Table 15 – Values for Sink
EnumValue ValueAsText Description
0DRAINmedium is passed into the cooling or system water outlet
1TANKmedium is conducted in a separate outlet

10.22.6 Mode

Description:Defines how the medium is to be emptied.

The TypeDefinition is MultiStateValueDiscreteType, so the Properties EnumValues and ValueAsText must be filled with the supported values out of Table 16.

Table 16 – Values for Mode
EnumValue ValueAsText Description
0PUMPEvacuation by the pump
1COMPRESSED_AIREvacuation with compressed air