Search
149 result(s) for HasComponent
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model4.5.3 DataVariablesalso visible in the AddressSpace . In this case, this complex DataVariable could define HasComponent References from it to the individual temperature values that it is composed
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model5.5.2 ObjectType NodeClassabstract ObjectType , i.e. Objects of this type can exist. References HasComponent 0..* HasComponent References identify the DataVariables , the Methods , and Objects contained in the ObjectType . If and how the referenced ... Attribute indicates if the ObjectType is abstract or not. The ObjectType NodeClass uses the HasComponent References to define the DataVariables , Objects , and Methods for it. The HasProperty Reference is used
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space ModelNodeClass . Organizes References can be used in any combination with HasChild References ( HasComponent , HasProperty , etc.; see 7.5 ) and do not prevent loops. Thus, they can be used to span multiple
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model5.6.2 Variable NodeClassDataVariable . Properties are not allowed to be the SourceNode of HasProperty References. HasComponent 0..* HasComponent References are used by complex DataVariables to identify their composed DataVariables . Properties are not allowed
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model5.6.3 Propertiestherefore they shall not be the SourceNode of any hierarchical References . This includes the HasComponent or HasProperty Reference , that is, Properties do not contain Properties and cannot expose their complex ... Reference . To distinguish them from DataVariables , they shall not be the TargetNode of any HasComponent Reference . Thus, a HasProperty Reference pointing to a Variable Node defines this Node
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model5.6.4 DataVariablespecified in Table 13 . DataVariables identify their Properties using HasProperty References . Complex DataVariables use HasComponent References to expose their component DataVariables . The Property NodeVersion indicates the version of the DataVariable ... also contain DataVariables . Therefore each DataVariable shall be the TargetNode of at least one HasComponent Reference coming from an Object , an ObjectType , a DataVariable or a VariableType . DataVariables shall
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model5.7.1 Method NodeClassClause 7 . A Method shall always be the TargetNode of at least one HasComponent Reference . The SourceNode of these HasComponent References shall be an Object or an ObjectType
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model6.4.4.4.4 OptionalPlaceholdermight have a Folder for DeviceParameters, and the DeviceParameters should be connected with a HasComponent Reference . However, the names of the DeviceParameters are specific to the instances. The example
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model6.4.4.4.5 MandatoryPlaceholdervalid as it uses the wrong ReferenceType to reference a DeviceParameter ( Organizes instead of HasComponent ) and Device C is not valid because it does not provide a DeviceParameter
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space ModelB.2 Notationobject diagrams are used to display <<TypeExtension>> objects (e.g. HasComponent in Figure B.3 ). In object diagrams, OPC Attributes are represented as UML attributes without data types ... with the stereotype <<Attribute>>, like InverseName in the UML object HasComponent . They have values, like InverseName =ComponentOf for HasComponent . To keep the object diagrams simple
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space ModelC.2.2 Simple notationexposed the same way as asymmetric ReferenceTypes except that an open arrow is used. HasComponent The notation provides a shortcut for HasComponent References shown on the left. The single hashed
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.12.2.2 ParametersObject or a super type of that ObjectType shall be the source of a HasComponent Reference (or subtype of HasComponent Reference ) to the Method specified in methodId . In case ... ObjectType , the ObjectType shall be the source of a HasComponent Reference (or subtype of HasComponent Reference ) to the Method specified in methodId. In this case the Method shall not have
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model4.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model11.21 HasAddInHasAddIn InverseName AddInOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of the HasComponent ReferenceType defined in 11.7 . Conformance Units Address Space AddIn Reference
-
OPC-10000-6 – OPC Unified Architecture - Part 6: MappingsF.9 UAMethodMethodDeclarationId NodeId May be specified for Method Nodes that are a target of a HasComponent reference from a single Object Node . It is the NodeId of the UAMethod with
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data AccessA.3.1.2 BranchBranch uses the Organizes References to reference child DA Branches and uses HasComponent References for DA Leafs (Items). It is acceptable for customized wrappers to use a sub-type
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditionsappear in the AddressSpace as an instance of some temperature transmitter Object with a HasComponent Reference to an instance of a LimitAlarmType . The availability of instances allows Data Access Clients
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditionsconcrete ReferenceType that can be used directly. It is a subtype of the HasComponent ReferenceType . The representation in the AddressSpace is specified in Table 5 This ReferenceType binds an AlarmSuppressionGroup
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditionscase since Variables (and VariableTypes ) are not allowed to be the source of a HasComponent Reference to an Object. Figure 29 provides an example of this use case. Note that ... LvelMonitoring" Alarm . It is Server -specific whether and where they assign a HasComponent Reference . Figure 29 - Use of HasCondition in a VariableType
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions9.2 AlarmMetricsTypeNodeClass BrowseName DataType TypeDefinition Modelling Rule Subtype of the BaseObjectType defined in 10000-5 . HasComponent Variable AlarmCount UInt32 BaseDataVariableType Mandatory HasComponent Variable StartTime UtcTime BaseDataVariableType Mandatory HasComponent Variable MaximumActiveState Duration ... BaseDataVariableType Mandatory HasComponent Variable MaximumUnAck Duration BaseDataVariableType Mandatory HasComponent Variable CurrentAlarmRate Double AlarmRateVariableType Mandatory HasComponent Variable MaximumAlarmRate Double AlarmRateVariableType Mandatory HasComponent Variable MaximumReAlarmCount UInt32 BaseDataVariableType Mandatory HasComponent Variable AverageAlarmRate Double
-
OPC-10000-10 – OPC Unified Architecture - Part 10: Programs5.2.5.2 ProgramTransitionEventTypeBrowseName DataType TypeDefinition ModellingRule Subtype of the base TransitionEventType defined in OPC 10000-16 . HasComponent Variable IntermediateResult BaseDataType BaseDataVariableType Mandatory Conformance Units Program Basic TransitionNumber identifies the Program transition that ... ObjectType for the IntermediateResult specifies the collection of Variables using a set of HasComponent References
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services7.10.4 ServerConfigurationallows access to the Server's configuration and it is the target of an HasComponent reference from the Server Object defined in OPC 10000-5 . This Object and its immediate
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global ServicesObjects which may be accessed via the Server . It is the target of an HasComponent reference from the ServerConfiguration Object defined in 7.10.4 . It is defined in Table 135 . Table
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services9.7.3 AuthorizationServicesObjects which may be accessed via the Server . It is the target of an HasComponent reference from the ServerConfiguration Object defined in 7.10.4 . It is defined in Table 157 . Table
-
OPC-10000-13 – OPC Unified Architecture - Part 13: Aggregates4.2.2.1 Generaltype definition. All Instances of the FolderType use the standard BrowseName of 'AggregateFunctions'. The HasComponent Reference is used to relate a ServerCapabilities Object and/or any HistoryServerCapabilitiesType Object to an AggregateFunction ... each HistoricalConfiguration Object belonging to a HistoricalDataNode may reference an AggregateFunction Object using the HasComponent Reference
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.3.10.5 ActionMethodsallowed to use the NodeId of a Method that is the target of a HasComponent Reference from the ObjectType of the Object . The namespace of the NodeId shall be added
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.3.6 HasPubSubConnectionconcrete ReferenceType that can be used directly. It is a subtype of the HasComponent ReferenceType . The SourceNode of References of this type shall be the PublishSubscribe Object defined ... BrowseName HasPubSubConnection InverseName PubSubConnectionOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of HasComponent defined in OPC 10000-5 . Conformance Units PubSub Model Base
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.5.9 HasWriterGroupconcrete ReferenceType that can be used directly. It is a subtype of the HasComponent ReferenceType . The SourceNode of References of this type shall be an instance of the PubSubConnectionType defined ... BrowseName HasWriterGroup InverseName IsWriterGroupOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of HasComponent defined in OPC 10000-5 . Conformance Units PubSub Model Base
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.5.10 HasReaderGroupconcrete ReferenceType that can be used directly. It is a subtype of the HasComponent ReferenceType . The SourceNode of References of this type shall be an instance of the PubSubConnectionType defined ... BrowseName HasReaderGroup InverseName IsReaderGroupOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of HasComponent defined in OPC 10000-5 . Conformance Units PubSub Model Base
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.6.6 HasDataSetWriterconcrete ReferenceType that can be used directly. It is a subtype of the HasComponent ReferenceType . The SourceNode of References of this type shall be an instance of the WriterGroupType defined ... BrowseName HasDataSetWriter InverseName IsWriterInGroup Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of HasComponent defined in OPC 10000-5 . Conformance Units PubSub Model Base
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.6.12 HasDataSetReaderconcrete ReferenceType that can be used directly. It is a subtype of the HasComponent ReferenceType . The SourceNode of References of this type shall be an instance of the ReaderGroupType defined ... BrowseName HasDataSetReader InverseName IsReaderInGroup Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of HasComponent defined in OPC 10000-5 . Conformance Units PubSub Model Base
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.9.3 SubscribedDataSetMirrorTypeModel SubscribedDataSet Mirror An Object of this type shall reference a mirror Object with HasComponent where the name of the Object is based on the ParentNodeName . The Method CreateDataSetMirror ... mirror Object shall reference Variables for each DataSet field in the DataSetMetaData with HasComponent . The name, DataType , ValueRank and ArrayDimensions of the Variables shall match the settings for the corresponding
-
OPC-10000-15 – OPC Unified Architecture - Part 15: Safety6.2.2.2 Safety ObjectType definitionsFigure 4 originating at SafetyProviderType or SafetyConsumerType and below shall be of ReferenceType HasComponent (and shall not be derived from ReferenceType HasComponent ) for Object References or ReferenceType HasProperty (and shall ... SafetyProviderType IsAbstract False References Node class BrowseName DataType TypeDefinition Modelling rule Subtype of SafetyObjectsType HasComponent Method ReadSafetyData Optional HasComponent Method ReadSafetyDiagnostics Optional HasComponent Object SafetyPDUs SafetyPDUsType Optional HasComponent Object Parameters
-
OPC-10000-16 – OPC Unified Architecture - Part 16: State Machines4.4.9 StateTypeshall be referenced from the ObjectType FiniteStateMachineType or one of its subtypes using a HasComponent Reference or a subtype of HasComponent and shall not have a ModellingRule as they
-
OPC-10000-16 – OPC Unified Architecture - Part 16: State Machines4.4.11 TransitionTypeshall be referenced from the ObjectType FiniteStateMachineType or one of its subtypes using a HasComponent Reference or a subtype of HasComponent and shall not have a ModellingRule as they
-
OPC-10000-16 – OPC Unified Architecture - Part 16: State Machines4.4.16 HasSubStateMachinesubtypes and the TargetNode shall be referenced from the same ObjectType , both using a HasComponent Reference or a subtype of HasComponent . The representation of the HasSubStateMachine ReferenceType in the AddressSpace
-
OPC-10000-16 – OPC Unified Architecture - Part 16: State Machines4.6.3 HasGuardconcrete ReferenceType and can be used directly. It is a subtype of HasComponent . The semantic of this ReferenceType is to point from a Transition to a Guard . The Guard indicates ... GuardOf Symmetric False IsAbstract False References NodeClass BrowseName DataType TypeDefinition ModellingRule Subtype of the HasComponent ReferenceType defined in OPC 10000-5 Conformance Units Base Info Choice States
-
OPC-10000-20 – OPC Unified Architecture - Part 20: File Transfer4.3.2 FileSystem ObjectBrowseName FileSystem . An OPC UA Server may have different FileSystem Objects in the AddressSpace . HasComponent is used to reference a FileSystem from aggregating Objects like the Objects Folder
-
OPC-10000-23 – OPC Unified Architecture - Part 23: Common ReferenceTypes4.6.1 Overviewother components, that the component requires in order to work. In contrast to the HasComponent ReferenceType , the related components are not considered to be subcomponents of the component. In contrast
-
OPC-10000-23 – OPC Unified Architecture - Part 23: Common ReferenceTypes4.12.2 Definitionconcrete ReferenceType and can be used directly. It is a subtype of HasComponent . The semantic of this ReferenceType is to relate a hardware component to its subcomponent, which is also ... BrowseName HasPhysicalComponent InverseName PhysicalComponentOf Symmetric FALSE IsAbstract FALSE References NodeClass BrowseName Comment Subtype of HasComponent defined in OPC 10000-5 Conformance Units Base Info HasPhysicalComponent
-
OPC-10000-25 – OPC Unified Architecture - Part 25: Object SerializationReferenceType Properties . IncludeReferenceTypes contains HierarchicalReferences . This selects Variable1 , Object1 and Property3 . ExcludeReferenceTypes contains HasComponent . This removes Variable1 and Object1 from the selection. Therefore, only Property3 referenced by HasProperty is mapped
-
OPC-10000-25 – OPC Unified Architecture - Part 25: Object SerializationSerializationEntity . This SerializationEntity sets the ReferenceTypes to select all hierarchical References but no HasComponent References . As result, "Property1" and "Property1.1" are excluded by the "ObjectSerialization
-
OPC-10000-25 – OPC Unified Architecture - Part 25: Object SerializationRioChannelType Object is reached, since these Objects only have components referenced using the HasComponent ReferenceType . To include the components of the RioChannelType Objects into the SerializationScope , each Channel Object references ... SerializationEntity" Object which has the IncludeReferenceType array Property containing the HasComponent ReferenceType . The ConsiderSubElementSerializationProperties SerializationProperty of the "SerializationEntity" (see 6.3.6 ) referenced by the SerializationStartNode causes the settings
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelconcrete ReferenceType and can be used directly. It is a subtype of HasComponent ReferenceType . The SourceNode of this ReferenceType shall be a ConnectionConfigurationSet . The TargetNode of this ReferenceType shall ... InverseName AutomationComponentConfigurationOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of the 0:HasComponent ReferenceType defined in OPC 10000-5 ConformanceUnits UAFX ConnectionManager Base
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelconcrete ReferenceType and can be used directly. It is a subtype of HasComponent ReferenceType . The SourceNode of this ReferenceType shall be an instance of AutomationComponentConfigurationType . The TargetNode of this ReferenceType ... InverseName AssetToVerifyOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of the 0:HasComponent ReferenceType defined in OPC 10000-5 ConformanceUnits UAFX ConnectionManager Base
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelconcrete ReferenceType and can be used directly. It is a subtype of HasComponent ReferenceType . The SourceNode of this ReferenceType shall be an instance of AutomationComponentCapabilitiesType . The TargetNode of this ReferenceType ... InverseName CapabilityOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of the 0:HasComponent ReferenceType defined in OPC 10000-5 ConformanceUnits UAFX AutomationComponent Base
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelconcrete ReferenceType and can be used directly. It is a subtype of HasComponent ReferenceType . The SourceNode of this ReferenceType shall be an instance of AutomationComponentConfigurationType . The TargetNode of this ReferenceType ... InverseName CharacteristicOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of the 0:HasComponent ReferenceType defined in OPC 10000-5 ConformanceUnits UAFX ConnectionManager Base
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelconcrete ReferenceType and can be used directly. It is a subtype of HasComponent ReferenceType . The SourceNode of this ReferenceType shall be an instance of ConnectionManagerCapabilitiesType . The TargetNode of this ReferenceType ... InverseName CMCapabilityOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of the 0:HasComponent ReferenceType defined in OPC 10000-5 ConformanceUnits UAFX ConnectionManager Base
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelconcrete ReferenceType and can be used directly. It is a subtype of HasComponent ReferenceType . The SourceNode of this ReferenceType shall be a ConnectionConfigurationSet . The TargetNode of this ReferenceType shall ... InverseName CommunicationFlowConfigurationOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of the 0:HasComponent ReferenceType defined in OPC 10000-5 ConformanceUnits UAFX ConnectionManager Base
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelconcrete ReferenceType and can be used directly. It is a subtype of HasComponent ReferenceType . The SourceNode of this ReferenceType shall be a ConnectionConfigurationSet . The TargetNode of this ReferenceType shall ... InverseName ConnectionConfigurationOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of the 0:HasComponent ReferenceType defined in OPC 10000-5 ConformanceUnits UAFX ConnectionManager Base
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelconcrete ReferenceType and can be used directly. It is a subtype of HasComponent ReferenceType . The SourceNode of this ReferenceType shall be an instance of ConnectionEndpointsFolderType . The TargetNode of this ReferenceType ... InverseName ConnectionEndpointOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of the 0:HasComponent ReferenceType defined in OPC 10000-5 ConformanceUnits UAFX FunctionalEntity Base
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelconcrete ReferenceType and can be used directly. It is a subtype of HasComponent ReferenceType . The SourceNode of this ReferenceType shall be a FunctionalEntity . The TargetNode of this ReferenceType shall ... InverseName ControlGroupOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of the 0:HasComponent ReferenceType defined in OPC 10000-5 ConformanceUnits UAFX FunctionalEntity Base
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelconcrete ReferenceType and can be used directly. It is a subtype of HasComponent ReferenceType . It provides for the nesting of InputGroups . The SourceNode of this ReferenceType shall be an instance ... InverseName InputGroupOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of the 0:HasComponent ReferenceType defined in OPC 10000-5 ConformanceUnits UAFX FunctionalEntity Base
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelconcrete ReferenceType and can be used directly. It is a subtype of HasComponent ReferenceType . It provides for the nesting of OutputGroups . The SourceNode of this ReferenceType shall be an instance ... InverseName OutputGroupOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of the 0:HasComponent ReferenceType defined in OPC 10000-5 ConformanceUnits UAFX FunctionalEntity Base
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelconcrete ReferenceType and can be used directly. It is a subtype of HasComponent ReferenceType . The SourceNode of this ReferenceType shall be a ConnectionConfigurationSet . The TargetNode of this ReferenceType shall ... InverseName ServerAddressOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of the 0:HasComponent ReferenceType defined in OPC 10000-5 ConformanceUnits UAFX ConnectionManager Base
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelorganised within the InputData and OutputData . In addition, these Variables are referenced by HasComponent References from the SafetyPDUs Object of the SafetyProvider (see also OPC 10000-15 ). Safety
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devices3.3.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devices6.4.3 TransferServices Objectused as container for the TransferServices Methods and shall have the BrowseName Transfer . HasComponent is used to reference from a Device to its "TransferServices" Object . The TransferServiceType
-
OPC-10000-100 – OPC Unified Architecture - Part 100: DevicesMethods and Properties and should have the BrowseName Lock . It shall be referenced using HasComponent or HasAddIn from the lock-owner Object (for example, a Device ). The LockingServicesType and each
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basics3.3.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basics10.5.3 AddLink Methodexternally managed resource by adding a Variable according to the input arguments with a HasComponent Reference to the Object the Method is called on. The server shall manage the added
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basics13.3.3.1 Generalhierarchy. The ReferenceType is not further restricted, it is recommended to use the HasComponent ReferenceType . The hierarchy spanned should not contain loops, however, Clients shall not rely on this
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basics13.4.3.1 Generalhierarchy. The ReferenceType is not further restricted, it is recommended to use the HasComponent ReferenceType . The hierarchy spanned should not contain loops, however, Clients shall not rely on this
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basics14.1 Sub-Assetsassets shall be referenced from the asset with a hierarchical Reference , preferable 0: HasComponent or a subtype of it. Assets may reference their sub-assets directly, or have additional grouping
-
OPC-10000-120 – OPC Unified Architecture - Part 120: OPC UA and XML Data Type Mapping3.3.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-10000-200 – OPC Unified Architecture - Part 200: Industrial Automation3.3.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-10000-200 – OPC Unified Architecture - Part 200: Industrial Automation6.3.1 HasStatisticComponentconcrete ReferenceType and can be used directly. It is a subtype of 0: HasComponent . The semantic of this ReferenceType is to link Variables to an Object or ObjectType managing statistical ... Object or ObjectType implementing the IStatisticsType interface. References NodeClass BrowseName Comment Subtype of 0:HasComponent defined
-
OPC-10000-210 – OPC Unified Architecture - Part 210: Relative Spatial Location3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-10000-211 – OPC Unified Architecture - Part 211: Global Positioning3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-10030 – OPC Unified Architecture - Common Object Model: ISA-955.1.7.6 UMLCompositeused to describe a strong form of aggregation, it is mapped to OPC UA HasComponent or subtypes of OPC UA HasComponent ReferenceType (see Table 9 ). Table 9 - Transformation rule
-
OPC-10030 – OPC Unified Architecture - Common Object Model: ISA-959.2.2 HasISA95ClassPropertyconcrete ReferenceType that can be used directly. It is a subtype of HasComponent . Table 80 - HasISA95ClassProperty ReferenceType Attributes Value BrowseName HasISA95ClassProperty InverseName ISA95ClassPropertyOf Symmetric False IsAbstract False References NodeClass BrowseName ... Comment Subtype of HasComponent defined in OPC 10000-5 This ReferenceType is used to describe the ownership of an ISA95ClassProperty and is compatible to the "HasPropertyOf
-
OPC-10031-4 – OPC UA for ISA-95 - Part 4: Job Control3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-10100-1 – OPC UA for WoT Connectivity - Part 1: API Definition3.4.1.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-30000 – OPC UA for Programmable Logic Controllers based on IEC61131-33.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-30000 – OPC UA for Programmable Logic Controllers based on IEC61131-3Variable <VarExternalName> BaseDataType BaseDataVariableType OptionalPlaceholder HasLocalVar Object <BlockName> CtrlFunctionBlockType OptionalPlaceholder HasComponent Variable Body XmlElement BaseDataVariableType Optional HasComponent Object <SFCName> SFCType OptionalPlaceholder The CtrlProgramOrganizationUnitType ObjectType ... Ctrl Program Organization Unit type are referenced with different subtypes of the HasComponent Reference . The used Reference type depends on the IEC 61131-3 variable declaration keywords. The characteristics
-
OPC-30000 – OPC UA for Programmable Logic Controllers based on IEC61131-3HasOutputVar Object <FunctionBlockOutputName> CtrlFunctionBlockType OptionalPlaceholder HasInOutVar Object <FunctionBlockInOutName> CtrlFunctionBlockType OptionalPlaceholder HasComponent Variable FunctionBlock BaseDataVariableType Optional The CtrlFunctionBlockType ObjectType is abstract. There will be no instances ... declared for a Ctrl Function Block type are referenced with different subtypes of the HasComponent Reference . The used Reference type depends on the IEC 61131-3 declaration keywords. The name
-
OPC-30000 – OPC UA for Programmable Logic Controllers based on IEC61131-38.2 HasInputVarHasInputVar This ReferenceType is a subtype of the HasComponent ReferenceType defined in OPC 10000-5 . Its representation in the AddressSpace is specified in Table 20 . Table 20 - HasInputVar ReferenceType Attributes ... BrowseName HasInputVar InverseName InputVarOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of HasComponent Reference Type defined in OPC 10000-5 The HasInputVar ReferenceType is a concrete ReferenceType
-
OPC-30000 – OPC UA for Programmable Logic Controllers based on IEC61131-38.3 HasOutputVarHasOutputVar This ReferenceType is a subtype of the HasComponent ReferenceType defined in OPC 10000-5 . Its representation in the AddressSpace is specified in Table 21 . Table 21 - HasOutputVar ReferenceType Attributes ... BrowseName HasOutputVar InverseName OutputVarOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of HasComponent Reference Type defined in OPC 10000-5 The HasOutputVar ReferenceType is a concrete ReferenceType
-
OPC-30000 – OPC UA for Programmable Logic Controllers based on IEC61131-38.4 HasInOutVarHasInOutVar This ReferenceType is a subtype of the HasComponent ReferenceType defined in OPC 10000-5 . Its representation in the AddressSpace is specified in Table 22 . Table 22 - HasInOutVar ReferenceType Attributes ... BrowseName HasInOutVar InverseName InOutVarOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of HasComponent Reference Type defined in OPC 10000-5 The HasInOutVar ReferenceType is a concrete ReferenceType
-
OPC-30000 – OPC UA for Programmable Logic Controllers based on IEC61131-38.5 HasLocalVarHasLocalVar This ReferenceType is a subtype of the HasComponent ReferenceType defined in OPC 10000-5 . Its representation in the AddressSpace is specified in Table 23 . Table 23 - HasLocalVar ReferenceType Attributes ... BrowseName HasLocalVar InverseName LocalVarOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of HasComponent Reference Type defined in OPC 10000-5 The HasLocalVar ReferenceType is a concrete ReferenceType
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices4.2.2 Graphical Notationtarget Node . The only exception is the HasSubtype Reference . The most important References like HasComponent , HasProperty , HasTypeDefinition and HasSubtype have special symbols avoiding the name of the Reference . For other
-
OPC-30020 – MDIS OPC UA Companion Specificationprior NodeSet file. For custom types the instance hierarchy shall be represented via HasComponent (standard OPC UA Reference ) or a custom ReferenceType that has been subtyped from HasComponent or Organizes
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model3.5.2.1 NodeIdscase "part of" means that the whole has a 0:HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model4.2.2 Graphical Notationtarget Node . The only exception is the HasSubType Reference . The most important References like HasComponent , 0:HasProperty , HasTypeDef i nition and HasSubType have special symbols avoiding the name
-
OPC-30040 – OPC UA for AutomationML - Xxx: OPC UA Information Model for AutomationML3.3.3.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-30040 – OPC UA for AutomationML - Xxx: OPC UA Information Model for AutomationML4.2.2 Graphical Notationtarget Node . The only exception is the HasSubType Reference . The most important References like HasComponent , HasProperty , HasTypeDef i nition and HasSubType have special symbols avoiding the name of the Reference
-
OPC-30060 – OPC UA for Tobacco Machine Communication3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-30081 – OPC UA for Process Automation Devices - PA-DIM™3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-30090 – OPC UA for Field Device Tool (FDT) - Part <mm>: <Part Name>3.3.4.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-30100 – OPC UA for SERCOS Devices4.3.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-30110 – OPC UA for POWERLINK - POWERLINK: OPC Unified Architecture3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-30110 – OPC UA for POWERLINK - POWERLINK: OPC Unified Architecture4.2.2 Graphical notationtarget Node . The only exception is the HasSubtype Reference . The most important References like HasComponent , HasProperty , HasTypeDef i nition and HasSubtype have special symbols avoiding the name of the Reference
-
OPC-30130 – OPC UA for Control & Communication System Profile(for Machine)4.2.2 Graphical notationtarget Node . The only exception is the HasSubType Reference . The most important References like HasComponent , HasProperty , HasTypeDefinition and HasSubType have special symbols avoiding the name of the Reference . For other
-
OPC-30130 – OPC UA for Control & Communication System Profile(for Machine)instantiated CSP+ machine ObjectType corresponding to the applicable machine and referred to by using HasComponent Reference from the DeviceSet entry point specified by the OPC 10000-100. Figure
-
OPC-30130 – OPC UA for Control & Communication System Profile(for Machine)6.4.1 Basic policyeach DataVariable referred to from ParameterSet Object of CSP+ machine ObjectType by using HasComponent Reference . The DataVariable s above are grouped both per CSPP section and per CSPP part. FunctionalGroupType ... CSPP sections are referred to from the CSP+ machine ObjectType by using HasComponent Reference , and the Object s corresponding to the CSPP parts are referred to from the Object
-
OPC-30130 – OPC UA for Control & Communication System Profile(for Machine)6.4.6.2 CSPP elementeach DataVariable referred to from ParameterSet Object of CSP+ machine ObjectType by using HasComponent Reference . The VariableType of each DataVariable is determined based on the following rules depending
-
OPC-30140 – OPC UA for PROFINET3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-30141 – OPC UA for PROFIenergy3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-30142 – OPC UA for PROFINET Remote IO3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-30143 – OPC UA for PROFINET Encoder - Part <mm>: <Part Name>3.5.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Model3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-30145 – OPC UA for PROFINET Drives - Part 30145: UA CS for PROFINET Drives3.5.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-30200 – OPC UA for Commercial Kitchen Equipment3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-30250 – OPC Unified Architecture for DEXPI4.2.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: Basics3.4.2.1 NodeIdsthis case, "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes which are not part of another Node have
-
OPC-34100 – OPC UA for Energy Consumption Management3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-34100 – OPC UA for Energy Consumption Management6.2.2.1 OverviewReferenceType shall be used to reference the Variable of EnergyMeasurementType (YES), or the 0: HasComponent ReferenceType shall be used (NO). Using 2: HasStatisticComponent indicates, that the Variable is aggregating values
-
OPC-34100 – OPC UA for Energy Consumption ManagementBaseObjectType 0:HasProperty Variable ApplicationTag 0:String 0:PropertyType M, RW 0:HasComponent Variable <MeasurementValue> 0:BaseDataType{Any} EnergyMeasurementValueType MP 0:HasComponent Method 2:ResetStatistics O 0:HasProperty ... reset are identified by being referenced using the 2:HasStatisticComponent (a subtype of 0: HasComponent ). The optional 2: StartTime indicates when the collection of aggregated data has started
-
OPC-40001-1 – OPC UA for Machinery - Part 1: Basic Building Blocks3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-40001-1 – OPC UA for Machinery - Part 1: Basic Building BlocksBrowseName "MachineryBuildingBlocks" (using the Namespace of OPC 40001-1), referenced with HasComponent or a subtype. All AddIns defined in this specification should be applied to this Object
-
OPC-40001-1 – OPC UA for Machinery - Part 1: Basic Building BlocksMachineComponentsType ObjectType Definition The MachineComponentsType provides HasComponent References to all identifiable components of a Machine and is formally defined in Table 26 . Table 26 - MachineComponentsType Definition Attribute Value BrowseName MachineComponentsType ... InstanceDeclarations of that Node. 0:HasProperty Variable 0:DefaultInstanceBrowseName 0:QualifiedName 0:PropertyType - 0:HasComponent Object <Component> 0:BaseObjectType OP Conformance Units Machinery Find Components of Machines
-
OPC-40010-1 – OPC UA for Robotics - Part 1: Vertical Integration3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-40020-1 – OPC UA for Cranes and Hoists - Part 1: Base Model Motion Devices System3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions3.2.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition Monitoring3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-40100-2 – OPC UA for Machine Vision - Part 2: Asset Management and Condition MonitoringInstanceDeclarations of that Node 0:HasAddIn Object 3:Components 3:MachineComponentsType O 0:HasComponent Object ComputingDevices VisionItemFolderType O 0:HasComponent Object DisplayUnits VisionItemFolderType O 0:HasComponent Object PhysicalInterfaces VisionItemFolderType ... HasComponent Object ImageSensors VisionItemFolderType O 0:HasComponent Object FrameGrabbers VisionItemFolderType O 0:HasComponent Object Lenses VisionItemFolderType O 0:HasComponent Object LensControllers VisionItemFolderType O 0:HasComponent Object OpticalFilters VisionItemFolderType
-
OPC-40223 – OPC UA for Pumps and Vacuum Pumps3.3.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-40301 – OPC UA for Flat Glass Processing3.5.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-40400-1 – OPC UA for the Powertrain - Part 1: Asset Management3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-40400-1 – OPC UA for the Powertrain - Part 1: Asset Managementconcrete ReferenceType and can be used directly. It is a subtype of HasComponent ReferenceType. It is used to link a PtAssetType with the attributes that are describing this asset ... HasPtAttributes InverseName PtAttributesOf Symmetric False IsAbstract False References NodeClass BrowseName Comment Subtype of the HasComponent ReferenceType defined in in OPC 10000-3. ConformanceUnits
-
OPC-40444 – OPC UA for Textile Testing Devices3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-40450-1 – OPC UA for Joining Systems - Part 1: Base3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job Management3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-40502 – OPC UA for Computerized Numerical Control (CNC) Systems - for CNC Systems: OPC UA Information Model3.3.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-40502 – OPC UA for Computerized Numerical Control (CNC) Systems - for CNC Systems: OPC UA Information Model4.2.2 Graphical Notationtarget Node . The only exception is the HasSubtype Reference . The most important References like HasComponent , HasProperty , HasTypeDef i nition and HasSubtype have special symbols avoiding the name of the Reference
-
OPC-40503-1 – OPC UA for Metal Forming - Part 1: General3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-40504-1 – OPC UA for Cutting Tools - Part 1: Manufacturing3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-40505 – OPC UA for Wireless Machine Tool Peripherals3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-40505 – OPC UA for Wireless Machine Tool Peripherals7.1.1 OverviewBrowseName DataType TypeDefinition Other Subtype of the BaseObjectType defined in OPC 10000-5 0:HasComponent Object DeviceConfiguration 0:FolderType O 0:HasComponent Object DeviceInformation 0:FolderType M 0:HasComponent Object ... WMTPWorkCycleData WMTPWorkCycleDataType O 0:HasComponent Object WMTPServiceCycleData WMTPServiceCycleDataType O 0:HasAddIn Object 3:LifetimeCounters 3:MachineryLifetimeCounterType O 0:HasAddIn Object 3:OperationCounters 3:MachineryOperationCounterType O 0:HasComponent Object Measurements
-
OPC-40530 – OPC UA for Laser Systems3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-40540 – OPC UA for Additive Manufacturing3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-40550-1 – OPC UA for Woodworking Machines - Part 1: Vertical Interface3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-40560 – OPC UA for Mining - General3.2.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-40570 – OPC UA for Wire Harness Manufacturing3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-40600 – OPC UA for Weihenstephan Standards3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-40700 – OPC UA for Surface Technology - General Types3.3.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-40700 – OPC UA for Surface Technology - General TypesIdentification 4:MachineIdentificationType O 0:HasAddIn Object 4:Components 4:MachineComponentsType O 0:HasComponent Object 4:Monitoring 4:MonitoringType O 0:HasComponent Object 4:MachineryBuildingBlocks 0:FolderType M 0:HasComponent ... STSysType Additional Subcomponents Source Path Reference NodeClass BrowseName DataType TypeDefinition Others 4:Monitoring 0:HasComponent Object 4:Status 0:FolderType O 4:Monitoring 4:Status 0:HasComponent Object 4:MachineryItemState
-
OPC-40700 – OPC UA for Surface Technology - General Typesdefined in OPC 10000-5 0:HasAddIn Object 2:Identification 4:MachineryComponentIdentificationType O 0:HasComponent Object 4:Monitoring 4:MonitoringType O 0:HasComponent Object 4:MachineryBuildingBlocks 0:FolderType ... HasComponent Object Description 0:FolderType O Identification is used as defined in OPC 40001-1. It represents numerous identification features of the component. Monitoring is representing a collection of ObjectTypes
-
OPC-40702 – OPC UA for Surface Technology - Organic Coating Technology - Material Supply Systems3.3.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-40702 – OPC UA for Surface Technology - Organic Coating Technology - Material Supply SystemsBrowseName DataType TypeDefinition Other Subtype of the 5:STSysType defined in OPC 40700 0:HasComponent Object 4:Monitoring 4:MonitoringType O 0:HasComponent Object 4:MachineryBuildingBlocks 0:FolderType ... HasComponent Object 5:Description 0:FolderType O Conformance Units MSS STSysMaterialTransportLineType Basic MSS STSysMaterialTransportLineType Monitoring MSS STSysMaterialTransportLineType Description Monitoring represents a collection of ObjectTypes and VariableTypes , representing the current state
-
OPC-40718 – OPC UA for Surface Technology - Shot Blasting Machinery3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-40718 – OPC UA for Surface Technology - Shot Blasting MachineryIdentification 3:MachineIdentificationType M 0:HasAddIn Object 3:Components 3:MachineComponentsType M 0:HasComponent Object ShotBlastMedia ShotBlastMediaType O 0:HasComponent Object Monitoring 0:FolderType O 0:HasComponent Object 3:MachineryBuildingBlocks ... ShotBlastMachineType Additional Subcomponents Source Path Reference NodeClass BrowseName DataType TypeDefinition Others 3:Components 0:HasComponent Object <ShotBlastChamber> ShotBlastChamberType MP 3:Components 0:HasComponent Object <Hopper> HopperType
-
OPC-40719 – OPC UA for Plasma Surface Technology3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have
-
OPC-40719 – OPC UA for Plasma Surface TechnologyIdentification 4:MachineIdentificationType M 0:HasAddIn Object 4:Components 4:MachineComponentsType M 0:HasComponent Object 4:Monitoring 4:MonitoringType M 0:HasAddIn Object 6:JobManagement 6:JobManagementType O 0:HasComponent ... according to the MachineryOperationCounterType of the OPC 40001-1 shall be integrated with the HasComponent reference under this Object . This Object shall also be referenced as AddIn in the MachineryBuildingBlocks
-
OPC-40719 – OPC UA for Plasma Surface Technologydefined in OPC 10000-5 0:HasAddIn Object 2:Identification 4:MachineryComponentIdentificationType O 0:HasComponent Object 4:Monitoring 4:MonitoringType M 0:HasComponent Object 4:MachineryBuildingBlocks 0:FolderType M Conformance ... according to the MachineryOperationCounterType of the OPC 40001-1 shall be integrated with the HasComponent reference under this Object . This Object shall also be referenced as AddIn in the MachineryBuildingBlocks
-
OPC-40719 – OPC UA for Plasma Surface Technologydefined in OPC 10000-5 0:HasAddIn Object 2:Identification 4:MachineryComponentIdentificationType O 0:HasComponent Object 4:Monitoring 4:MonitoringType M 0:HasComponent Object 4:MachineryBuildingBlocks 0:FolderType M Conformance ... according to the MachineryOperationCounterType of the OPC 40001-1 shall be integrated with the HasComponent reference under this Object . This Object shall also be referenced as AddIn in the MachineryBuildingBlocks
-
OPC-40740 – OPC UA for Process Air Extraction and Filtration Systems (PAEFS)3.4.2.1 NodeIdsthis case "part of" means that the whole has a HasProperty or HasComponent Reference to its part. Since all Nodes not being part of another Node have