Description:Actual operating mode of the TCD.
Table 6 – OperatingModeEnumeration Values
| 
 Name  | 
        
 Value  | 
        
 Description  | 
| 
 OTHER  | 
        
 0  | 
        
 Operating mode of the TCD is unknown  | 
| 
 READY_TO_OPERATE  | 
        
 1  | 
        
 TCD is ready to operate (heating, pump and cooling are switched off)  | 
| 
 NORMAL_OPERATION  | 
        
 2  | 
        
 TCD is running in normal operating mode  | 
| 
 LEAK_STOPPER  | 
        
 3  | 
        
 TCD is running in leak stopper operating mode  | 
| 
 MOULD_EVACUATION  | 
        
 4  | 
        
 TCD is carrying out a mould evacuation process  | 
| 
 PRESSURE_RELIEF  | 
        
 5  | 
        
 TCD is carrying out a pressure relief process  | 
| 
 COOLING  | 
        
 6  | 
        
 TCD is cooling down to StandbyTemperature and switch off  | 
| 
 SAFETY_COOLING  | 
        
 7  | 
        
 TCD is cooling down to SwitchingOffTemperature and switch off  | 
| 
 ECO  | 
        
 8  | 
        
 TCD is running in Eco operating mode (energy is saved via the reduced pump speed)  | 
| 
 BOOST  | 
        
 9  | 
        
 TCD is running in Boost operating mode (pump runs at maximum possible speed)  |