13.2 Profiles

13.2.1 Profile list

The following tables specify the facets available for Servers that implement the OPC 40082-3 Information Model companion specification.

NOTE: The names of the supported profiles are available in the Server Object under ServerCapabilities.ServerProfileArray

Table 28 lists all Profiles defined in this document and defines their URIs.

Table 28 – Profile URIs for OPC 40082-3
Profile URI
OPC 40082-3 Basic Server Profilehttp://opcfoundation.org/UA-Profile/PlasticsRubber/LDS/Server/Basic
OPC 40082-3 Alarms Server Facethttp://opcfoundation.org/UA-Profile/PlasticsRubber/LDS/Server/Alarms

13.2.2 Server Facets

13.2.2.1 Overview

The following sections specify the Facets available for Servers that implement the OPC 40082-3 companion specification. Each section defines and describes a Facet or Profile.

13.2.2.2 OPC 40082-3 Basic Server Profile
Table 29 - OPC 40082-3 Basic Server Profile
Group Conformance Unit / Profile Title Mandatory / Optional
OPC 40082-3OPC 40082-3 BasicM
Profile0:ComplexType Server FacetM
Profile0:Method Server FacetM
Profile2:BaseDevice Server FacetM
OPC 40082-3OPC 40083 TolerancesO
OPC 40082-3OPC 40082-3 DosingFunctionO
OPC 40082-3OPC 40082-3 PurgeO
OPC 40082-3OPC 40082-3 PurgeCyclicO
OPC 40082-3OPC 40082-3 SelectableMaterialBalanceSystemO
OPC 40082-3OPC 40082-3 DeliveryPressureO
OPC 40082-3OPC 40082-3 FlowrateO
OPC 40082-3OPC 40082-3 MixingRatioTargetO
OPC 40082-3OPC 40082-3 BalanceSystemO
OPC 40082-3OPC 40082-3 Identify DeviceO
OPC 40082-3OPC 40082-3 ResetAllErrorsO
OPC 40082-3OPC 40082-3 ResetErrorByIdO
OPC 40082-3OPC 40082-3 SetCycleNumberO
OPC 40082-3OPC 40082-3 ActualShotWeightO
OPC 40082-3OPC 40082-3 SetShotWeightO
OPC 40082-3OPC 40082-3 SetValueCompositeDensityO
OPC 40082-3OPC 40082-3 RemainingMaterialTimeO
OPC 40082-3OPC 40082-3 AdditiveO
OPC 40082-3OPC 40082-3 SetValueDensityO
OPC 40082-3OPC 40082-3 SetSetValueDensityO
OPC 40082-3OPC 40082-3 ActualPressureO
OPC 40082-3OPC 40082-3 ActualFollowerPlatePressureO
OPC 40082-3OPC 40082-3 SetFollowerPlatePressureO
OPC 40082-3OPC 40082-3 DrumCapacityO
OPC 40082-3OPC 40082-3 ResidualAmountO
OPC 40082-3OPC 40082-3 RemainingMaterialTimeO
OPC 40082-3OPC 40082-3 AllowsCyclesO
OPC 40082-3OPC 40082-3 AdditiveFractionO
OPC 40082-3OPC 40082-3 AdditiveStrokeVolumeO
OPC 40082-3OPC 40082-3 AdditiveClosedLoopControlO
13.2.2.3 OPC 40082-3 Alarms Server Facet
Table 30 - OPC 40082-3 Alarms Server Facet
Group Conformance Unit / Profile Title Mandatory / Optional
OPC 40082-3OPC 40082-3 AlarmsM
Profile0:A & C Alarm Server FacetM