13.1 Conformance Units

This chapter defines the corresponding Conformance Unit for OPC 40082-3.

Table 27 – Conformance Units for OPC 40082-3
Category Title Description
ServerOPC 40082-3 BasicSupport of LDS_InterfaceType and all mandatory child elements giving information on the LDS and its status. There is at least one instance of the LDS_InterfaceType in the Machines Object.
ServerOPC 40082-3 AlarmsSupport of HelpOffNormalAlarmType, ComponentAlarmType and AdditiveAlarmType providing error information. If this facet is supported and a client subscribes to the events, the server shall provide all errors via alarms in addition to the error variables included in the OperationType
ServerOPC 40083 TolerancesSupport of Status, UpperTolerance and LowerTolerance in the MonitoredParameterType and ControlledParameterType and the according alarms.
ServerOPC 40082-3 DosingFunctionSupport of StartDosing, StopDosing and DosingActive in the OperationType
ServerOPC 40082-3 PurgeSupport of PurgeMode, PurgeStatus, PurgeQuantitiy and PurgeTimeout in the OperationType
ServerOPC 40082-3 PurgeCyclicSupport of OPC 40082-3 Purge, the PurgeMode CYCLIC_COMPONENT_A_B and PurgeCyclicQuanitity, PurgeCyclicIdleTime, PurgeCyclicActive in the OperationType
ServerOPC 40082-3 SelectableMaterialBalanceSystemIf SELECTABLE is supported in the MaterialBalanceSystemTypeEnumeration, the variable AcivateMaterialBalanceSystem has to be supported.
ServerOPC 40082-3 DeliveryPressureIf DeliveryType PRESSURE is supported, DeliveryPressure and DeliveryPressureMeasuringPoint have to be supported
ServerOPC 40082-3 FlowrateIf DeliveryType VOLUMETRIC_FLOWRATE is supported, DeliveryFlowRate has to be supported
ServerOPC 40082-3 MixingRatioTargetIf a Material balance system is used, MixingRatioTarget has to be supported
ServerOPC 40082-3 BalanceSystemIf a Material balance system is used, MaxDeviationMixingRatio, TargetDeviationMixingRatio, ActualDeviationMixingRatio have to be supported.
ServerOPC 40082-3 Identify DeviceSupport of the IdentifyDevice Method in the OperationType
ServerOPC 40082-3 ResetAllErrorsSupport of the ResetAllErrors Method in the OperationType
ServerOPC 40082-3 ResetErrorByIdSupport of the ResetErrorById Method in the OperationType
ServerOPC 40082-3 SetCycleNumberSupport of the SetCycleNumber Method in the OperationType
ServerOPC 40082-3 ActualShotWeightSupport of the ActualShotWeight Variable in the OperationType
ServerOPC 40082-3 SetShotWeightSupport of the SetShotWeight Variable in the OperationType
ServerOPC 40082-3 SetValueCompositeDensitySupport of the SetValueCompositeDensity Variable in the OperationType
ServerOPC 40082-3 RemainingMaterialTimeSupport of the RemainingMaterialTime Variable in the OperationType
ServerOPC 40082-3 AdditiveSupport of the AdditiveType with all its mandatory child elements
ServerOPC 40082-3 SetValueDensitySupport of the SetValueDensity Variable in the ComponentType
ServerOPC 40082-3 SetSetValueDensitySupport of the SetSetValueDensity Method and the SetValueDensity Variable in the ComponentType
ServerOPC 40082-3 ActualPressureSupport of the ActualPressure Variable in the ComponentType
ServerOPC 40082-3 ActualFollowerPlatePressureSupport of the ActualFollowerPlatePressure Variable in the ComponentType
ServerOPC 40082-3 SetFollowerPlatePressureSupport of the SetFollowerPlatePressure Variable in the ComponentType
ServerOPC 40082-3 DrumCapacitySupport of the DrumCapacity Variable in the ComponentType
ServerOPC 40082-3 ResidualAmountSupport of the ResidualAmount Variable in the ComponentType
ServerOPC 40082-3 RemainingMaterialTimeSupport of the RemainingMaterialTime Variable in the ComponentType
ServerOPC 40082-3 AllowsCyclesSupport of the AllowsCycle Variable in the ComponentType
ServerOPC 40082-3 AdditiveFractionSupport of AdditiveFraction in the AdditiveType
ServerOPC 40082-3 AdditiveStrokeVolumeSupport of AdditiveStrokeVolume in the AdditiveType
ServerOPC 40082-3 AdditiveClosedLoopControlSupport of ActivateClosedLoopControl and ClosedLoopControlActivated in the AdditiveType