12.1 ComponentAlarmType
The ComponentAlarmType represent component-related text messages (alarms, error messages, warnings, information) of the peripheral device and is a subtype of HelpOffNormalAlarmType as defined in OPC 40083.
NOTE: For messages related to the whole device, the HelpOffNormalAlarmType shall be used.
| Attribute | Value | ||||
| BrowseName | ComponentAlarmType | ||||
| IsAbstract | False | ||||
| References | Node Class | BrowseName | DataType | TypeDefinition | Modelling Rule |
|---|---|---|---|---|---|
| Subtype of 3:HelpOffNormalAlarmType defined in OPC 40083 | |||||
| Conformance Units | |||||
|---|---|---|---|---|---|
| OPC 40082-3 Alarms |
The SourceNode (included in BaseEventType) shall contain the NodeId of the related component. In case of medium or high severity, the IMM can sort out bad parts or stop production.