12.1 Conformance Units

This chapter defines the corresponding Conformance Units for the OPC UA Information Model for PE Energy Management.

Table 61 – Conformance Units for PE Energy Management
Category Title Description
ServerPNEM Standby ManagementSupports the Standby Management functionality defined in Standby Management Information Model.
ServerPNEM Standby Management ControlSupports the Standby Management functionality defined in Standby Management Information Model. The Methods StartPause, EndPause, PauseTime are supported.
ServerPNEM Energy MeasurementSupports the Energy Measurement functionality defined in Energy Measurement Information Model.
ServerPNEM Sleep Mode WOLSupports the Sleep Mode WOL functionality defined in Sleep Mode WOL Functionality Information Model.
ServerPNEM Energy Management SupportSupports at least one of the Conformance Units: PNEM Standby Management, PNEM Energy Measurement or PNEM Power Off.
ServerPNEM PROFIenergySupports the PeServiceAccessPointType ObjectType defined in PE Energy Management Information Model (The device implements the PROFIenergy Common Application Profile).
ServerPNEM EnergyProfile E0 IEnergyProfileE0 Interface is supported by EnergyMeasurementType Object instances.
ServerPNEM EnergyProfile E1 IEnergyProfileE1 Interface is supported by EnergyMeasurementType Object instances.
ServerPNEM EnergyProfile E2 IEnergyProfileE2 Interface is supported by EnergyMeasurementType Object instances.
ServerPNEM EnergyProfile E3 IEnergyProfileE3 Interface is supported by EnergyMeasurementType Object instances.
ServerPNEM EnergyProfile D0 IEnergyProfileD0 Interface is supported by EnergyMeasurementType Object instances.

12.2 Profiles

12.2.1 Profile list

Table 62 lists all Profiles defined in this document and defines their URIs.

Table 62 – Profile URIs for PE Energy Management
Profile URI
PNEM Energy Management Server Profile http://opcfoundation.org/UA-Profile/PNEM/Server/EnergyManagement
PNEM PROFINET Energy Management Server Profile http://opcfoundation.org/UA-Profile/PNEM/Server/PROFINETEnergyManagement
PNEM Energy Management Control Server Profile http://opcfoundation.org/UA-Profile/PNEM/Server/EnergyManagementControl
PNEM PROFINET Energy Management Control Server Profile http://opcfoundation.org/UA-Profile/PNEM/Server/PROFINETEnergyManagementControl
PNEM Energy Controller Server Facet http://opcfoundation.org/UA-Profile/PNEM/Server/EnergyController

12.2.2 Server Facets

12.2.2.1 Overview

The following sections specify the Facets available for Servers that implement the PE Energy Management companion specification. Each section defines and describes a Facet or Profile.

12.2.2.2 PNEM Energy Management Server Profile
Table 63 – PNEM Energy Management Server Profile
Group Conformance Unit / Profile Title M / O
PNEMPNEM Standby ManagementO
PNEMPNEM Energy MeasurementO
PNEMPNEM Sleep Mode WOLO
PNEMPNEM EnergyProfile E0O
PNEMPNEM EnergyProfile E1O
PNEMPNEM EnergyProfile E2O
PNEMPNEM EnergyProfile E3O
PNEMPNEM EnergyProfile D0O
PNEMPNEM Energy Management SupportM
Profile0:Nano Embedded Device 2017 Server Profile
http://opcfoundation.org/UA-Profile/Server/NanoEmbeddedDevice2017
M
Profile0:Data Access Server Facet
http://opcfoundation.org/UA-Profile/Server/DataAccess
M
Profile0:ComplexType 2017 Server Facet
http://opcfoundation.org/UA-Profile/Server/ComplexTypes2017
M
Subscription Services0:SubscriptionDurable
http://opcfoundation.org/UA-Profile/Server/DurableSubscription
M
12.2.2.3 PNEM Energy Management Control Server Profile
Table 64 – PNEM Energy Management Control Server Profile
Group Conformance Unit / Profile Title M / O
ProfilePNEM Energy Controller Server FacetM
ProfilePNEM Energy Management Server ProfileM
Profile0:Embedded Device 2017 Server Profile
http://opcfoundation.org/UA-Profile/Server/EmbeddedUA2017
M
12.2.2.4 PNEM PROFINET Energy Management Server Profile
Table 65 – PNEM Energy PROFINET Management Server Profile
Group Conformance Unit / Profile Title M / O
PNEMPNEM PROFIenergyM
ProfilePNEM Energy Management Server ProfileM
12.2.2.5 PNEM PROFINET Energy Management Control Server Profile
Table 66 – PNEM PROFINET Energy Management Control Server Profile
Group Conformance Unit / Profile Title M / O
ProfilePNEM PROFIenergyM
ProfilePNEM Energy Management Control Server ProfileM
12.2.2.6 PNEM Energy Controller Server Facet
Table 67 – PNEM Energy Controller Server Facet
Group Conformance Unit / Profile Title M / O
PNEMPNEM Standby Management ControlM
Profile2:Locking_Server_FacetM

12.2.3 Client Facets