Description:If RemoteControlActivated = 2, the two Methods (without arguments) are used to start and stop the dosing. With the Variable DosingActive the LDS can inform the IMM, if dosing is really active.

NOTE: The dosing can also be stopped by the LDS itself (e.g. when SetShotWeight has been reached) to avoid everlasting dosing when the client does not call the method StopDosing.

Signatures:

StartDosing();

StopDosing();

The methods have no Input- or OutputArguments.

Table 16 – StartDosing Method AddressSpace Definition

Attribute

Value

BrowseName

StartDosing

References

Node Class

BrowseName

DataType

TypeDefinition

Modelling Rule

Table 17 – StopDosing Method AddressSpace Definition

Attribute

Value

BrowseName

StopDosing

References

Node Class

BrowseName

DataType

TypeDefinition

Modelling Rule