9 OPC UA EventTypes

9.1 PtDriveAxisEventType

The PtDriveAxisEventType is the abstract base for the EventTypes provided by the different subtypes of the PtDriveAxisType. Derived EventTypes render certain components mandatory, dependent on the nature of the event reported.

Table 60 - PtDriveAxisEventType Definition
AttributeValue
BrowseNamePtDriveAxisEventType
IsAbstractTrue
ReferencesNode ClassBrowseName DataTypeTypeDefinitionOther
Subtype of 0:BaseEventType defined in OPC 10000-5.
0:HasPropertyVariableAxisState0:UInt160:PropertyTypeM, RO
0:HasPropertyVariableControlPriority0:UInt160:PropertyTypeM, RO
0:HasPropertyVariableConverterOutputCurrent0:Float0:PropertyTypeO, RO
0:HasPropertyVariableConverterOutputPower0:Float0:PropertyTypeO, RO
0:HasPropertyVariableTorqueForceActualValue0:Float0:PropertyTypeO, RO
0:HasPropertyVariableMotorTemperature0:Float0:PropertyTypeO, RO
0:HasPropertyVariableConverterTemperature0:Float0:PropertyTypeO, RO
0:HasPropertyVariableDeviceTemperature0:Float0:PropertyTypeO, RO
0:HasPropertyVariableDcBusVoltage0:Float0:PropertyTypeO, RO
0:HasPropertyVariablePositionFollowingError0:Float0:PropertyTypeO, RO
0:HasPropertyVariableVelocityFollowingError0:Float0:PropertyTypeO, RO
0:HasPropertyVariableControlMode0:UInt160:PropertyTypeO, RO
0:HasPropertyVariable<EncoderxTemperature>0:Float0:PropertyTypeOP, RO
0:HasPropertyVariableBleederTemperature0:Float0:PropertyTypeO, RO
Conformance Units
Powertrain Limit Events

The Properties provided are the components of the "Monitoring" folder (for a description see Table 54 section for Monitoring folder). The Values of these properties shall constitute a snapshot of the Axis/DO state when the Event is fired.

9.2 PtAxisSwOvertravelEventType

The PtAxisSwOvertravelEventType Event is fired if a motion range software limit of the axis is exceeded.

Table 61 - PtAxisSwOvertravelEventType Definition
AttributeValue
BrowseNamePtAxisSwOvertravelEventType
IsAbstractFalse
ReferencesNode ClassBrowseName DataTypeTypeDefinitionOther
Subtype of PtDriveAxisEventType.
HasPropertyVariableIsUpperSwLimit0:Boolean0:PropertyTypeM, RO
Conformance Units
Powertrain Limit Events

The IsUpperSwLimit Property indicates whether the upper software limit is exceeded (True) or the lower software limit is exceeded (False).

9.3 PtAxisHwOvertravelEventType

The PtAxisHwOvertravelEventType is fired if a motion range hardware limit of the axis is exceeded.

Table 62 - PtAxisHwOvertravelEventType Definition
AttributeValue
BrowseNamePtAxisHwOvertravelEventType
IsAbstractFalse
ReferencesNode ClassBrowseName DataTypeTypeDefinitionOther
Subtype of PtDriveAxisEventType.
HasPropertyVariableIsUpperHwLimit0:Boolean0:PropertyTypeM,RO
Conformance Units
Powertrain Limit Events

The IsUpperHwLimit Property indicates whether the upper hardware limit is exceeded (True) or the lower hardware limit is exceeded (False).

9.4 PtTorqueForceLimitEventType

The PtTorqueForceLimitEventType Event is fired if a torque/force range limit of the axis is exceeded.

Table 63 - PtTorqueForceLimitEventType Definition
AttributeValue
BrowseNamePtTorqueForceLimitEventType
IsAbstractFalse
ReferencesNode ClassBrowseName DataTypeTypeDefinitionOther
Subtype of PtDriveAxisEventType.
HasPropertyVariableTorqueForceActualValue0:Float0:PropertyTypeM, RO
HasPropertyVariableTorqueForceLimit0:Float0:PropertyTypeM, RO
Conformance Units
Powertrain Limit Events

The TorqueForceActualValue Property contains the actual torque/force value.

The TorqueForceLimit Property contains the torque/force limit which was exceeded causing the Event to be fired.

9.5 PtMotorCurrentLimitEventType

The PtMotorCurrentLimitEventType Event is fired if a motor current limit of the axis's motor is exceeded.

Table 64 - PtMotorCurrentLimitEventType Definition
AttributeValue
BrowseNamePtMotorCurrentLimitEventType
IsAbstractFalse
ReferencesNode ClassBrowseName DataTypeTypeDefinitionOther
Subtype of PtDriveAxisEventType.
0:HasPropertyVariableConverterOutputCurrent0:Float0:PropertyTypeM, RO
0:HasPropertyVariableMotorCurrentLimitHigh0:Float0:PropertyTypeM, RO
Conformance Units
Powertrain Limit Events

The ConverterOutputCurrent Property contains the actual motor current.

The MotorCurrentLimitHigh Property contains the upper motor current limit exceeded causing the Event to be fired.

9.6 PtLogbookEventType

Table 65 - PtLogbookEventType Definition
AttributeValue
BrowseNamePtLogbookEventType
IsAbstractFalse
ReferencesNode ClassBrowseName DataTypeTypeDefinitionOther
Subtype of 0:BaseEventType defined in OPC 10000-5.
0:HasPropertyVariableLogEntryPtLogEntryDataType0:PropertyTypeM, RO
Conformance Units
Powertrain Logbook Events

The LogEntry Variable contains a new or a modified log entry. A modification of a log entry usually means that the EventGoing or the EventAcknowledged or both fields of the PtLogEntryDataType structure are set with a valid time.

9.7 PtLogObjectEventType

Table 66 - PtLogObjectEventType Definition
AttributeValue
BrowseNamePtLogObjectEventType
IsAbstractFalse
ReferencesNode ClassBrowseName DataTypeTypeDefinitionOther
Subtype of 0:BaseLogEventType defined in OPC 10000-26.
0:HasPropertyVariableLogEntryPtLogEntryDataType0:PropertyTypeM, RO
Conformance Units
Powertrain LogObject Events

The LogEntry Variable corresponds to the LogEntry Property of the PtLogbookEventType.

9.8 PtLogbookAlarmType

The PtLogbookAlarmType provides the same information as the PtLogbookEventType but uses OPC UA Alarms & Conditions defined in OPC 10000-9.

Table 67 - PtLogbookAlarmType Definition
AttributeValue
BrowseNamePtLogbookAlarmType
IsAbstractFalse
ReferencesNode ClassBrowseName DataTypeTypeDefinitionOther
Subtype of 0:AlarmConditionType defined in [OPC 10000-9].
0:HasPropertyVariableLogEntryPtLogEntryDataType0:PropertyTypeM, RO
Conformance Units
Powertrain Diagnosis Alarms