7.5 PtCharacteristicsConverterType

The PtCharacteristicsConverterType represents the properties of the electric converter unit belonging to an electric drive.

Table 48 - PtCharacteristicsConverterType
AttributeValue
BrowseNamePtCharacteristicsConverterType
IsAbstractFalse
ReferencesNode ClassBrowseName DataTypeTypeDefinitionOther
Subtype of the 0:BaseObjectType defined in OPC 10000-5.
0:HasComponentVariableBleederExcessCurrentLimit0:Float0:AnalogUnitTypeO, RO
0:HasComponentVariableConverterExcessCurrentConfigured0:Float0:AnalogUnitTypeO, RO
0:HasComponentVariableConverterThermalLoadLimitConfigured0:Float0:AnalogUnitTypeO, RO
0:HasComponentVariableDcBusVoltageConfigured0:UInt160:AnalogUnitTypeO, RO
0:HasComponentVariableInputConverterAcInputVoltage0:UInt160:AnalogUnitTypeO, RO
0:HasComponentVariableOutputConverterPulseFrequency0:Float0:AnalogUnitTypeM, RO

The BleederExcessCurrentLimit Variable contains the excess current limit of the brake resistor in ampere.

The ConverterExcessCurrentConfigured Variable contains the excess current of the converter determined by configuration data.

The ConverterThermalLoadLimitConfigured Variable contains the thermal load limit of the converter determined by configuration data.

The DcBusVoltageConfigured Variable contains the voltage of the intermediate circuit determined by configuration data.

The InputConverterAcInputVoltage Variable contains the input alternating voltage.

The OutputConverterPulseFrequency Variable contains the pulse frequency of the converter.