8.1.3 ILimitSupervisionElectric
The ILimitSupervisionElectric Interface specifies the Variables representing electric properties which are components of the LimitSupervision Folder. Instances of the LimitSupervision folder shall reference this InterfaceType if the containing Powertrain Axis Object represents an electric Drive.
| Attribute | Value | ||||
| BrowseName | ILimitSupervisionElectric | ||||
| IsAbstract | True | ||||
| References | Node Class | BrowseName | DataType | TypeDefinition | Other |
|---|---|---|---|---|---|
| Subtype of the 0:BaseInterfaceType defined in OPC 10000-5. | |||||
| 0:HasComponent | Variable | MotorCurrentLimitLow | 0:Float | 0:AnalogUnitType | O, RO |
| 0:HasComponent | Variable | MotorCurrentLimitHigh | 0:Float | 0:AnalogUnitType | O, RO |
| Conformance Units | |||||
|---|---|---|---|---|---|
| Powertrain Actual and Command Values |
The MotorCurrentLimitHigh Variable contains the currently active upper motor current limit of the Powertrain Axis Object.
The MotorCurrentLimitLow Variable contains the currently active lower motor current limit of the Powertrain Axis Object.